Original source · versioned page text
Acoustic Report
4.1.1 Unattended Ambient Noise Monitoring Rion NL42 environmental noise monitors were placed at 79 Ferrells Road (Monitor 1) and onsite at 3 Taylor Court (Monitor 2) to measure the existing ambient noise levels. These locations were selected as they were considered representative of the nearest residential receivers. The monitors were located in free field positions with the microphones approximately 1.4 metres above ground surface level. The noise monitors were set to record noise levels between the 29th March and 5th April 2022. The environmental noise monitors were set to record noise levels in "A" Weighting, Fast response using 15-minute statistical intervals. Ambient noise monitoring was conducted generally in accordance with Australian Standard AS 1055:2018 Acoustics – Description and measurement of environmental noise. Refer to Figure 2 for noise monitoring locations. 2022123 R01C 3 Taylor Court Cooroy ENV.docx © Acoustic Works 2022 Page 7