Assumptions for Calculations
The following assumptions were adopted for quantification of the design fire (credible worst case scenario).
Assumed values are listed below:
Vegetation: Short Heathland & Tall Heathland
Effective Slope (degrees): 1 - flat
Separation Distance (m): 15
Flame Width (m): 100
Flame Angle (degree): 81
Flame Temperature (K): 1090
Flame Emissivity: 0.95
Overall Fuel Load (t/ha): 15 (low heath) 25 (tall heath)
Relative Humidity (%): 25
Ambient Temperature (K): 308
Heat of Combustion (kJ/kg): 18600
Elevation of Receiver (m): 3.82
Fire Run (km): >1km