existing site plan
1: 200

RPD

lot 565

rp 48112
parish of weyba
county of ---
locality:
sunshine coast
regional council
area: 506m?

 

 

 

 

 

 

 

 

 

 

ja

 

 

 

 

 

 

i

 

 

 

 

 

 

 

a

 

 

 

 

 

 

 

 

 

 

 

 

 

3
8
~~
178° 10.00"
= Oo
r6s8s |
i
' |
\ 7
be \ \ S| |
\
\ ross _—_scresent .
. x
'
}
‘existing areas proposed areas
lower floor 182.81 m?| entry 4.48 m?|,
entry 4.48 m2 laundry/oath 15.99 maf.
lower patio 16.91 m? lower floor 166.90 me||
upper floor 160.34 m? lower patio 16.91 m2|}
upper patio 40,57 m? proposed alterations 117.41 mI,
tear patio 3.29 m? upper floor 55.23 m2
Grand total 408.39 m? upper north patio 18.04 m?
upper rear patio 3.29 m?}]
upper south patio 19.44 m?|
Grand total 417.68 m?
existing site cover 204.20m? (40.35%) total site cover 213.49m? (42.19%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

proposed site plan

1: 200

   

 

18 2 Se AES a

_——

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i i
1000mm exposed \ , I 4
aggregate path \ -V ‘ &
around house: \ vo 7 !
Noe \ \ |
~ the 09d | \ have sal
> 4 | (
of Liat. 4
AS > *
& & south dock Ia
\ KS)
Se & § 3
2 Slo
? 2) 2
2
2/3
1285545. 2/3
1 . é
\ 6649 178° 1000"
\ 16886 |

Rew exposed aggrogate ,
concrete driveway to replace
existing

{

 

 

 

 

 

 

ross _—cresent .

       

general notes *
1. Figured dimensions take preceden
2. All work to comply with BCA, QLD Building Act and Local Authority Regulations.

3. Site to be cut and filled in accordance ith Geotechnical Engineers specifications. all
levels to be confirmed on site proir to construction.

4. Excavations to be in accordance with BCA 3.1.1 and Engineers design.

5. Drainage work to comply with Geotechnical Engineers recommendations and the
Siructural Engineers details. Ap
6. All timber framing to comply with AS 1684.2.
7. All plumbing and drainage work to be carried out in accordance with AS/NZS 3500 and
Council Regulations. i

8. All earthworks , footings and slabs in ac€ordance with Engineers design and details.

9. Termite protection to AS 3660-1. (Termimesh or equal)

10. Driveway and crossovers to be in accordance with Councils standard drawing details.
11. Consulting engineers details and specifications are to take precedence over these
drawings.
12. Landscape works to be confirmed by client

er scaled dimensions.

 

  

  

 

ADocuments end Setings Vanity DocumentsWORK PROJEGTSonptan 20011005 marimit005 marin 3.04}

 

 

 

 

 

 

 

  

 

 

 

   

 

 

 

 

 

 

 

; /
DESIGN DRAFTING onplan pty Itd clam revisions (dato drawn by sheet name »Y
Pp Pp y A concept 14/02/10 april 2010 im A . tf site lans
PAUL CURRIE 0413 998 089 fax 5491 8389 i i i B concept revision 08/09/10 aoa honk not tor
IAN McKINVEN 0411 524 530 fax 5446 22 ian & jo martin c 21/03/10 ep no. sheet i} | | | construction ple
[email protected] [email protected] o 19/04/10 1005, a purposes issue
box 215, motfat beach qld 4551 . 7 .
ee roa) Z 36-ross-cresent, sunshine_beach.. - scale (89) preliminary
www.onpian.com.au L acn 125 105 928 abn 33 658 335 908 ) y J 12042010 10:30:47 PM _) \ 1: 200 > \ iv) 7 . ; S
q

Used in these records

About this file

File size
3.4 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

10_0916 - Preliminary Building Approvals [As Published].pdf · 3.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.