Attached to the e-mail Change to Building Envelope - GIA - 152004.240041.3.
Plans and drawings: the text below has words only, no drawings.
ROOF TRUSSES GENERALLY AT 900mm MAX. CTRS ROOF RAFTERS GENERALLY AT 900mm MAX. CTRS
STRICTLY IN ACCORDANCE WITH THE STRICTLY IN ACCORDANCE WITH THE STRUCTURAL
MANUFACTURER'S DETAILS AND SPECIFICATIONS. ENGINEER'S DETAILS AND SPECIFICATIONS.
TCH
OF PI
15° RO
CEILING
JOINERY
BED 2
2,700
2,400
FFL 160.50
SWIMMING
SELECTED FLOORING OVER TIMBER FLOOR FRAME
ALL IN ACCORDANCE WITH THE STRUCTURAL
POOL
ENGINEER'S DETAILS AND SPECIFICATIONS.
SELECTED DECKING (MATCH EXISTING) OVER TIMBER REINFORCED CONCRETE BLOCK PERIMETER WALLS
FLOOR FRAME ALL IN ACCORDANCE WITH THE WITH REINFORCED CONCRETE SLAB OVER
STRUCTURAL ENGR'S DETAILS & SPECIFICATIONS. CONSOLIDATED FILL STRICTLY IN ACCORD. WITH THE
STRUCTURAL ENGINEER'S DETAILS AND SPECS.
C
SECTION 4
PROTECTION AGAINST SUBTERRANIAN TERMITES TO BE IN
ACCORD. WITH AS 3660 - PART 1 (PROTECTION OF BUILDINGS
FROM SUBTERRANIAN TERMITES). magica building design
creative solutions
SLAB ON GROUND CONSTRUCTION :
PROTECTION AGAINST SUBTERRANIAN TERMITES TO BE IN ACCORD. WITH AS 3660 m . 0405 494 264
PART 1 - PROTECTION OF BUILDINGS FROM SUBTERRANIAN TERMITES. Carlo Magini c.s .e . - Building Designer.
PROTECTION AGAINST SUBTERRANIAN TERMITES TO APPLY TO ALL "PRIMARY BUILDING Lic. N o 1177987 - QBSA act 1991
ELEMENTS". e . [email protected] o m .a u
THE BUILDER IS TO PROVIDE PHYSICAL BARRIERS TO THE ENTRY BY SUBTERRANIAN w. w w w .magicabuildingdesign.c o m .a u
TERMITES BY CONSTRUCTION OF ALL SLABS IN ACCORDANCE WITH AS 2870.1 - PO Box 5859, Maroochydore BC. 4558
RESIDENTIAL FOOTING AND SLAB CONSTRUCTION.
IN ADDITION ALL SLAB PENETRATIONS ARE TO BE PROTECTED USING STAINLESS STEEL MESH
(TERMIMESH OR EQUIVELANT) FITTED IN ACCORD. WITH THE MANUF. DETAILS AND TIMBER FLOOR CONSTRUCTION : CLIENT STAGE
BUILDING APPROVAL
SPECIFICATIONS. M. AND D. VENTURA. BUILDING APPROVAL
EXTERNAL PERIMETER BARRIERS TO BE INSTALLED BY EXCAVATION OF TRENCHES, TREATING THE BUILDER IS TO PROVIDE PHYSICAL BARRIERS TO ENTRY BY SUBTERRANEAN TERMITES PROJECT ADDRESS
THE EXPOSED TRENCHES PRIOR TO BACKFILLING THE TRENCH WITH TREATED MATERIAL AND BY PROVIDING GALV. MS ANT CAPS OR SIMILAR PHYSICAL BARRIER TO TOPS OF SELECTED
PROTECTING THE TRENCH WITH A 300mm WIDE (MEASURED FROM THE EXTERNAL WALL OF THE FLOOR FRAME SUPPORT POSTS.ALL TIMBER SUPPORT POSTS TO HAVE SAP WOOD TREATED BOOYONG DRIVE, BLACK MOUNTAIN , QLD.
BUILDING) x 50mm THICK CONCRETE "MOWING" STRIP. WITH AN APPROVED PRESERVATIVE TO H5 LEVEL WHERE POSTS IN DIRECT CONTACT WITH SHEET TITLE
TWO (2) DURABLE NOTICES SHALL BE INSTALLED IN PROMINENT LOCATIONS, STATING METHOD GROUND. SECTION
OF PROTECTION USED, DATE OF INSTALLATION, LIFE EXPECTANCEY OF METHOD USED, AND ORIGINAL SCALE SHT SIZE DRWN CHKD DATE
SCOPE AND DURATION OF FUTURE INSPECTION.
REGULAR INSPECTION OF THE BUILDING ARE TO BE CARRIED OUT TO ENSURE THE BARRIER HAS
REGULAR COMPETENT INSPECTIONS OF THE BUILDING ARE TO BE CARRIED OUT TO ENSURE
THE BARRIER HAS NOT BEEN BRIDGED BY TERMITES. INSPECTIONS ARE TO BE CARRIED OUT
1:100 A3 C. M. C. M. 15 11 18
DRAWING No SHEET
18 - 021
NOT BEEN BRIDGED BY TERMITES. ALL INSPECTIONS ARE TO BE CARRIED OUT AS PER THE AT INTERVALS NOT EXCEEDING TWELVE (12) MONTHS. ALL INSPECTIONS ARE TO BE ISSUE
NOTICES. INSTIGATED BY THE PROPRIETOR AND ALL FUTURE PROPRIETORS OF THE BUILDING . 09 of 10 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
33997 plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.