D24CAL Working Drawings - Issue B
Attached to the e-mail Request for GIA - MCU220063 - General In Accordance - Amendment Request with correct plans - 25 Lawnville Rd COOROY.msg.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
LEGEND - INTERNAL
BUSHFIRE REQUIREMENTS - BAL29 MINIMUM FLOOR LEVEL MUST BE NOT LESS THAN WIND CATEGORY - REF ENG. SPEC BC - BROOM CUPBOARD
C'BD - CUPBOARD
R.L 112.4m A.H.D DP - DOWNPIPE
DW - DISHWASHER PROV.
DESIGN IN ACCORDANCE WITH AS 3959-2018 SITE COVER FW - FLOOR WASTE
REFER SECTION 3 & 7 FOR DETAILED REQUIREMENTS NOTE: WHERE THE SLAB HEIGHT IS DESIGNED TO BE WITHIN SITE AREA : 22910.00 m²
N
HP - HOT PLATE
200mm OF THE MIN FLOOR LEVEL A LICENSED SURVEYOR HWS - HOT WATER SYSTEM
DWELLING SITE COVER : 1.41 % ( 323.10 m²) L - LINEN
WATER & GAS SUPPLY MUST PROVIDE A FLOOR HEIGHT VERIFICATION MH - MANHOLE
OUTDOOR AREA SITE COVER : 0.16 % ( 36.40 m²) MW - MICROWAVE PROV.
(i) ALL EXPOSED WATER AND GAS SUPPLY LINES TO BE CERTIFICATE.
METAL. TOTAL SITE COVERAGE : 1.57 % ( 359.50 m²) OHC - OVERHEAD CUPBOARD
PTY - PANTRY
R - ROBE
REF - REFRIDGERATOR SPACE
OPENINGS RH - RANGEHOOD
5
(i) DOOR/WINDOWS TO BE SCREENED. MAX APERTURE SIZE S-FW - SMARTWASTE
3
2mm EXISTING DRIVEWAY SH - SHELF
SP285507
Lot 4
ESTIMATED EXISTING SHED POSITION TR - TOWEL RAIL
(ii) VENTS/WEEPHOLES TO BE MESH COVERED TO MEET BAL TRH - TOILET ROLL HOLDER
6
Found
4
REQUIRMENTS. MAX APERTURE 2mm UBO - UNDER-BENCH OVEN
Mk
No
Found
89°59'
Peg
WO - WALL OVEN
7
(141.461)
(iii) DOOR/WINDOW FRAMES TO BE MADE OF FIRE-RESISTANT 61
°30
103°41
71°3
LEGEND - EXTERNAL
6'20
TIMBER
8.8 '40 " '20" 18.5 "
14.917
93 78
Found
Peg
Found
Power Pole
Mk
No
BV - BRICK VENEER
#457034
(iv) GARAGE DOOR TO BE FITTED WITH NON-COMBUSTABLE
8
Found
94°58'10"
Mk
No
EL - HARDIES EASYLAP
41
18.128
2
WEATHERSTRIP FC - HARDIFLEX SHEETING
42
Property Pole
1
19°1 4
WITH MAX 3mm GAPS FTC - HARDIES FINE TEXTURE CLAD
107
9'55
.78
RH - RENDERED HEBEL PANELS
(v) ALL GLAZING TO COMPLY WITH REQUIREMENTS
"
RB - RENDERED BRICKWORK
ESTIMATED EXISTING HSTP POSITION RBL - RENDERED BLOCKWORK
20125 WALL
20891 WALL
ROOFING SA - SCYON AXON
SL - SCYON LINEA
RL 114.046
TBM1 Nail in Dumpy
40
(i) SKYLIGHTS TO BE MADE FROM A NON-COMBUSTABLE
39
Shipping Container SM - SCYON MATRIX PANELING
MATERIAL Bott 113.0 5
SS - SCYON STRIA CLADDING
WB - HARDIES NEWPORT
om
(ii) ANY ATTACHED ITEM ON ROOF (ie ANTENNA) ARE TO BE
9
of
Ba n
113.
k
11 3. 01
14
ADEQUATELY
10
11 3.8
Top
3840
9
of Ba
SEALED TO THE ROOF TO PREVENT GAPS >3mm AND BE PROPERTY
11
3.1 nk 113.9
0W
1
1 11 11
Stake Found
3.9 2.9
1
ALL
5
MADE
11
3.9
DESCRIPTION
113.
1
78
38
FROM A NON-COMBUSTABLE MATERIAL 4050
11
LOT 6 SP139173
11
3.7
4.0
2
0W
8
(iii) VENTILATION OPENINGS SHALL BE FITTED WITH EMBER- ALL LOCAL NOOSA
37
11
11 4.
113
2.5
.3 3
GUARDS
08
113.6
9
11
COUNCIL : SHIRE
3.7
Top
2
6
11
Bo
3.9
1
BE MADE FROM A NON-COMBUSTABLE MATERIAL AND
tto
of B
CUT
Bo
35
AREA : 2.291ha
m
tto
Stake Found
an
36
of
FILL
m
k
11
Ba
11
HAVE A MAX APERTURE SIZE OF 2mm
3.9
3.9
of
nk 11
8
7
an B
2.
k
(iv) SARKING/ANTICON MUST HAVE A FLAME-INDEX GREATER
57
Top
113.7of B
113.0
THAN 5. ISSUE
0 a nk
6
114.1
11
11
3
3.7
4.0
11
3
3
11
3.9
(v) SARKING TO COVER ENTIRE ROOF AREA TO EDGE OF # DATE DETAILS BY
3.7
0
3
112.75
- 09-05-24 NHP ISSUE JS
112.50
FASCIA. 34
14 1
112.33
112.28
.0