081128 - Lots 5 - 8 Soil Tests · OPW18/0155
Attached to the e-mail Operational Works Application - Geotechnical Report.msg.
Very large file (15.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
EXPLANATION OF NOTES, ABBREVIATIONS & TERMS Bicou USED ON BOREHOLE AND TEST PIT REPORTS DRILLING/EXCAVATION METHOD HQ Diamond Core - 63 mm AS* Auger Screwing RD Rotary blade or drag bit AD* Auger Drilling RT Rotary Tricone bit NMLC Diamond Core - 52 mm "vv V-Bit RAB __ Rotary Air Blast NQ Diamond Core - 47 mm ‘T TC-Bit, e.g. ADT RC Reverse Circulation BH Tractor Mounted Backhoe HA Hand Auger PT Push Tube EX Tracked Hydraulic Excavator ADH Hollow Auger CT Cable Tool Rig EE Existing Excavation DTC Diatube Coring JET Jetting HAND Excavated by Hand Methods WB Washbore or Bailer NDD Non-destructive drilling PENETRATION/EXCAVATION RESISTANCE L Low resistance. Rapid penetration possible with little effort from the equipment used. M Medium resistance. Excavation/possible at an acceptable rate with moderate effort from the equipment used. H High resistance to penetration/excavation. Further penetration is possible at a slow rate and requires significant effort from the equipment. R Refusal or Practical Refusal. No further progress possible without the risk of damage or unacceptable wear to the digging implement or machine. These assessments are subjective and are dependent on many factors including the equipment power, weight, condition of excavation or drilling tools, and the experience of the operator. WATER Ww Water level at date shown <J Partial water loss Cc Water inflow <4 Complete water loss GROUNDWATER NOT The observation of groundwater, whether present or not, was not possible due to drilling OBSERVED water, surface seepage or cave in of the borehole/test pit. GROUNDWATER NOT The borehole/test pit was dry soon after excavation. However, groundwater could be ENCOUNTERED present in less permeable strata. Inflow may have been observed had the borehole/test pit been left open for a longer period. SAMPLING AND TESTING SPT Standard Penetration Test to AS1289.6.3.1-1993 4,7,11 N=18 4,7,11 = Blows per 150mm. _N = Blows per 300mm penetration following 150mm seating 30/80mm Where practical refusal occurs, the blows and penetration for that interval are reported RW Penetration occurred under the rod weight only HW Penetration occurred under the hammer and rod weight only HB Hammer double bouncing on anvil DS Disturbed sample BDS Bulk disturbed sample G Gas Sample Ww Water Sample FP Field permeability test over section noted FV Field vane shear test expressed as uncorrected shear strength (sy = peak value, s, = residual value) PID Photoionisation Detector reading in ppm PM Pressuremeter test over section noted PP Pocket penetrometer test expressed as instrument reading in kPa U63 Thin walied tube sample - number indicates nominal sample diameter in millimetres WPT Water pressure tests Ranking of Visually Observable Contamination and Odour (for specific soil contamination assessment projects) R=0 No visible evidence of contamination R=A No non-natural odours identified R=1 Slight evidence of visible contamination R=B Slight non-natural odours identified R=2 Visible contamination R=C Moderate non-natura! odours identified R=3 Significant visible contamination R=D Strong non-natural odours identified ROCK CORE RECOVERY TCR = Total Core Recovery (%) SCR = Solid Core Recovery (%) RQD = Rock Quality Designation (%) _ SAxial lengths of core > 100mm « - Length of core run _ Length of core recovered «100 - > Length of cylindrical core recovered x 100 Length of core run Length of core run 100 GAP Form No. 6 RLS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
081128 - Lots 5 - 8 Soil Tests.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.