“SEWER NOTES
PIPELINES
1. ALL SEWERS ARE TO BE 150 8 uPVC CLASS SNB - AS12680 - RUBBER RING JOINTEO.
UNLESS NOTED OTHERWISE. FOR SEWERS DEEPER THAN 3.0 m, uPVC CLASS 12
PRESSURE PIPE TO AS1477 SHALL GE USED. INSIDE EDGE OF CLASS 12 PIPE TO 8E
CHAMFERED TO PROVIDE A SMOOTH TRANSITION OF FLOWS WHEN USED IN
CONJUNCTION WITH OTHER CLASSES OF PIPES AND FITTINGS.
2. ALIGNMENTS UNLESS NOTED OTHERWISE SHALL BE:
2.1. 1.$0m INSIDE FRONT BOUNDARY OF ALLOTMENTS
2.2. 1.50m INSIDE REAR BOUNDARY OF ALLOTMENTS
2.3. 1.00m FROM SIDE BOUNDARY OF ALLOTMENTS
3 BEDDING FOR PIPELINES TO BE TYPE 1 UNLESS OTHERWISE NOTED AND PLACED IN
ACCORDANCE WITH S.C.R.C. STANDARD ORG. No. 8813, IN COASTAL SAND TERRAIN ,
EXCAVATED MATERIAL MAY BE USED FOR BEDDING SUBJECT TO THE APPROVAL OF THE
COUNCIL, ALL OTHER AREAS SHALL USE WASHED 5mm.- 10mm SCREENINGS AS
BEDDING ANDO BACKFILLING MATERIAL.
4, MINIMUM COVER FOR SEWER PIPES SHALL BE 1.0 METRE FOR ALLOTMENTS AND
FOOTPATHS , AND 1.5 METRES FOR ROADWAYS
HOUSE CONNECTION BRANCHES
5. THE FOLLOWING CRITERIA ARE TO BE TAKEN INTO ACCOUNT WHEN SETTING THE
r INVERT LEVEC OF AN KCB...
5.1. DEPTH TO INSPECTION OPENING SHALL BE BETWEEN 0.6m AND 1.5m
§.2. INSPECTION OPENING SHALL CONTROL THE ALLOTMENT AT A GRADE OF 1 IN 60
5.3, WITH 300mm COVER AT HEAD OF DRAIN
5,4. (C) DEPTHS IN EXCESS OF 1.5m ARE NOT ACCEPTABLE
6. HOUSE CONNECTION JUMP-UPS ON SEWERS DEEPER THAN 2.0m SHALL BE
“SUGDON" FIBREGLASS REINFORCED DROP JUNCTIONS.
+ HOUSE CONNECTION BRANCHES TO EXTEND AT LEAST 1.8m INTO PROPERTY BEING
SERVED.
8. ALL HOUSE CONNECTION BRANCHES TO BE TYPE A , P OR F ANDO CONSTRUCTED IN
ACCORDANCE S.C.R.C, STANOARDO ORG. No. 6821H.
8. HOUSE CONNECTION BRANCHES TO BE 150mm DIAMETER UNLESS NOTED
OTHERWSE.
WORK ON EXISTING SEWERS
10. ALL WORK ON EXISTING SEWERS TO BE PERFORMED BY APPROVED CONTRACTOR
UNLESS OTHERWSSE DIRECTED BY THE COUNCIL , AND ACTUAL COST INCLUDING
LABOUR AND MATERIALS SHALL BE MET BY THE DEVELOPER.
SEWER MANHOLES
Qe052008 11:16:40 AM
41. MANHOLES SHALL BE PRE-CAST 1070mm DIA. UNLESS OTHERWISE NOTED AND
CONSTRUCTED IN ACCORDANCE WITH §.C.R.C. STANDARD DRAWINGS Nos. 9822¢, 9843 &
9848a.
GENERAL NOTES
1.
2.
3
4.
Ss.
ALL WORK IS TO BE CARRIED OUT TO THE STANDARDS OF, AND TO THE APPROVAL OF
THE S.C.R.C. ANO THE ENGINEER.
THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE S.C.R.C. STANDARD
ORAWINGS :
9613 SEWER CONSTRUCTION TRENCHES & BEDDING
8821H HOUSE CONNECTION BRANCHES) -
9822C SEWER MANHOLES
9843 DUCTILE IRON SEWER MANHOLE COVERS
964BA SEWER MANHOLE - PRECAST COMPONENTS AND BASE
. PROPERTY BOUNDARIES SHALL 8E STAKED PRIOR TO SEWERAGE CONSTRUCTION AND
SEWERAGE MANHOLE LOCATIONS CHECKED BY CONTRACTOR TO ENSURE BOUNDARY
CLEARANCES ARE ACHIEVED - THE CONTRACTOR SHALL NOT RELY SOLELY ON SEWER
CHAINAGES TO SET OUT MANHOLES.
FINAL SURFACE LEVELS OF MANHOLES ARE TO BE ADJUSTED ON SITE TO SUIT ALL
EARTHWORKS. - TYPICALLY 75mm ABOVE SURROUNDING FINISHED SURFACE LEVELS.
THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES BEFORE
COMMENCEMENT OF WORK ON SITE.
6. ALL TRENCH EXCAVATION AND CONSTRUCTION IS TO 8E tN ACCORDANCE WITH THE
CONSTRUCTION SAFETY ACT 1971-1975 AS AMENDED, AND THE MINES REGULATIONS ACT.
Sunshine Coast Regional Council
Development Permit Operational Works No: 2438. E38...
PROVAL
es... |i ORAWANG TITLE
ra || PROPOSED INDUSTRIAL SUBDIVISION SEWERAGE RETICULATION
grea || VENTURE DRIVE, NOOSAVILLE N
for GATEWAY RISE PTY LTD
SS LOT 14 ON SP170295
Saircummes || PARISH OF WEYSA
sae oe HORIZ OATUAA
ue an COUNTY OF MARCH VERT ‘ont
NOOSA COUNCIL APPROVAL No 2007/1626
4 108352
RL 3818 AnD
OP WORKS APPROVAL
wee tom Domne
ASSOCIATED CONSULTANT
PROJECT STRATEGY QLD Pty Ltd
Mabde OLS SESE ST
Telephone : (07) 444 0727
Fucsinée : (0) Seat O27
1 proecutreacyQpipard.co
tome 1 €2 Bate Avene, Aecantre Headae OLD <7?
MURRAY & ASSOCIATES
EET Se bch nae ee
TODCONSULTING
20 Mary Steet, Noosaville
P.O. Bax 61, Noosaville OLD 4565
Phone {07) 5449 9600 Fax (07) 5449 Base
+ enquiries @ptodcantuting com
ENGINEERS ee eb: Sr dooeonsuting om
oe =O 5 Hopend Om hae Mi
STRUCTURAL CIVIL => apca toms iS Snowe
tam AMD
Too CONSULTING PTY.LTD. = L= = Bille =
ABN. 39125 005 55 06583 2 Tal
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0658 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.