Attachment 3 - 20150352 - Decision Notice

Attached to the e-mail Industrial Business Type 2 Production, Alteration, Repackaging & Repairing - MCU19/0011.

of 7

Page text shows just the words. Original shows the document exactly as it was published.

32.   Electrical supply to essential services shall be protected in accordance with Part C2.13 of the BCA. At the
      completion of the installation, a certificate signed by a Licensed Electrician certifying the compliance of the
      installation shall be submitted to Pacific BCQ prior to the issue of a Form 11- Certificate of Classification.

33.   Illuminated fire exit signs are to be provided to all fire egress doorways and passages in accordance with Part E4 of
      the BCA. At the completion of the installation, a certificate signed by a Licensed Electrician certifying the
      compliance of the installation shall be submitted to Pacific BCQ prior to the issue of a Form 11- Certificate of
      Classification.

Building - Sound Insulation

34.   Separating walls and floors between two or more sole occupancy units and waste pipes or other penetrations that
      serves or passes through such elements shall have a Weighted Sound Reduction Index (RW ) value and provide
      insulation against impact sound not less than specified in Part F5.2 of the BCA or Section 3.8.6 of the BCA Vol 2
      (Housing provisions) as applicable.

Building – Heath and Amenity

35.   Light and ventilation is to be provided to all rooms in accordance with Part F4 of the BCA.

36.   The mechanical ventilation system required to the amenities area is to comply with Part F4.5 of the BCA.

37.   When installed, the mechanical ventilation and/or air-conditioning systems are to comply with Part F4.5 of the
      Building Code of Australia 2006. At the completion of the installation, a Form 16 Aspect Certificate signed by a
      suitably qualified person certifying the compliance of the installation shall be submitted to Pacific BCQ prior to the
      issue of a Form 11- Certificate of Classification.

38.   The door of every fully enclosed sanitary compartment shall open outwards, slide or be readily removable from the
      outside unless there is a clear space of 1.2m between the closet pan within the sanitary compartment and the
      nearest part of the doorway in accordance with Part F2.5 of the BCA.

39.   Walls and floors of wet areas to be made impervious to water in accordance with the provisions of Part F1.7 of the
      BCA. Proprietary waterproofing systems are to comply with the provisions of A.S 3740-2010.

      Where applicable, a Form 16 Aspect Certificate signed by a QBCC Licensed Contractor holding the requisite
      Waterproofing Licences and certifying the compliance of the installation, shall be submitted to Pacific BCQ prior to
      the issue of a Form 21 Final Inspection Certificate.

40.   Where floor wastes are provided, the wet area floors must be constructed so that water flows to the waste without
      ponding.

41.   Workplace areas and facilities for employees are to be designed and provided in accordance with the minimum
      provisions of MP 5.1 of the QDC.

Building – Access and Facilities for the Disabled

42.   Facilities for people with disabilities are to be provided in accordance with Part F2.4 of the BCA. Such provisions
      must be designed and constructed in accordance with AS 1428-2009.

43.   Access for people with disabilities must be provided to and within the building including any sanitary facilities and
      other areas normally used by the occupants by means of a continuous path of travel from the allotment boundary
      and from any accessible car parking space in accordance with Part D3 of the BCA.

44.   Clear and legible signs, incorporating Braille, identifying each accessible sanitary facility, lift and path of travel to an
      accessible entrance must be installed in accordance with Part D3 of the BCA.

45.   Access and egress paths must be provided with tactile ground surface indicators in accordance with Part D3 of the
      BCA.

46.   Hearing augmentation devices shall be provided in accordance with Part D3 of the BCA.

General – Previous Approvals

47.   The proposed development shall be carried out in accordance with the local authority’s Material Change of Use
      Approval No: DWALLACE:PBA15/0007 Dated: 16 July 2015




                                                            Page 6 of 7
Log in to download the original file

Attachment 3 - 20150352 - Decision Notice.pdf · 152 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.