Residential Uses Code
minimise the ability to directly look into
neighbouring homes and yards).
Access to Sunlight S14.1 Development does not reduce sunlight to at S14.1 – Complies
O14 For Multiple housing, buildings and structures least 50% of the private open space areas of any The development is fully compliant with height
are designed and sited so as not to unreasonably adjoining residences to less to than 2 hours provisions and allows for more than required
diminish the existing sunlight to adjoining between 9am and 3pm on any day of the year;
landscaping. It will not unduly impact on the
residences and associated private open space OR
areas; S14.2 Where overshadowing by existing structures amenity to adjoining residences in terms of over
AND and fences occurs to more than 50% of the private shadowing
O15 Multiple housing is designed and sited to open space areas of any adjoining residences,
minimise the extent of shadows cast on solar sunlight is not further reduced by more than 20%.
photovoltaic cells on roofs of adjoining buildings. (See Figure 14-4—Preventing overshadowing)
S15.1 No solution provided
Sloping sites S16.1 Buildings and structures on sloping sites— S16.1 – Not Applicable
O16 On sloping sites, buildings and structures are a) Have a maximum distance of 3m between the The subject site is flat.
designed to maximise the use of the natural ground and the lowest part of the floor of the
topography and minimise the need for cut and fill. building or the building incorporates undercroft
skirting or screening (eg. timber battens) to the full
height of any undercroft area higher than 3m
above ground level at the perimeter of the building;
b) are of split level design that step down the slope
or have suspended floor construction;
c) limit the amount of cut or fill to less than 2m in
depth relative to natural ground level; and
d) do not result in the spread of fill beyond the
footprint of the building and associated batters.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
APPENDIX C - CODE ASSESSMENT.pdfRelated documentApplication case desk ↗
APPENDIX C - CODE ASSESSMENT.pdfRelated documentApplication case desk ↗
APPENDIX C - CODE ASSESSMENT.pdfRelated documentApplication case desk ↗
About this file
- File size
- 844 KB (small file)
- File type
No other editions are linked here.