Landscaping Code
	
  


pedestrians are evident, are planted so as to   for a 2.0m high tree at planting and are able to
maximise vehicle and pedestrian safety.         attain a clear trunk height of 1900mm on
                                                maturity;
                                                AND
                                                S6.2 All scrub planting to be a maximum height
                                                of
                                                700mm from the road pavement (not top of
                                                kerb).
Services and utilities                          S7.1 Plant species used in landscaping               S7.1-7.6 Not Applicable
O7 All landscaping works maintain adequate      adjacent to substations, or adjacent to or on
                                                                                                     There are no electrical services and utilities that will
safe distance from services and utilities       electricity transmission line easements, are less
                                                                                                     be affected by landscaping.
including substations, overhead powerlines,     than 4m high at maturity and do not encroach
power poles and transformers, street lamps,     within 3m of a substation boundary;
stormwater catchment pits, and underground      OR
services and utilities.                         S7.2 For trees higher than 4m, trees are
                                                planted
                                                at a distance from any part of an electricity
                                                transmission line at least equal to the expected
                                                height of the tree at maturity (see Figure 14-17);
                                                AND
                                                S7.3 For power lines that connect to a
                                                premises,
                                                the height of plant species at maturity provides
                                                for
                                                a 2m clearance below the power line; (see
                                                Figure
                                                14-18)
                                                AND

                                                S7.4 Trees and large scrubs are located a
                                                minimum of—
                                                a) 5m from electricity poles and pillars;
                                                b) 4m from street lamps;
                                                c) 2m from stormwater catchment pits; and
                                                d) 2m from underground services and utilities;




	
  

Used in these records

About this file

File size
844 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

APPENDIX C - CODE ASSESSMENT.pdf · 844 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.