M3 SURVEYS
S
LEGEND GRADE FILL FROM 2.4m AHD TO FALL
TOWARDS HOUSE ON ALL SIDES OF OVERLAND
6000
WALL A.B.N 16 709 184 516
S
PROPERTY FLOW TO
T COMMUNICATIONS MANHOLE 6055 EXISTING SLEEPER RETAINING STREET 5000 Ph 0402 825 835
COMMS.
UP TO AHD2.300 RETAINING FILL S S
COMMUNICATIONS PILLAR WALL
726
TO NEIGHBOURING PROPERTY. HOOD/EAVE
[email protected]
WALL
NAIL IN KERB
44°0'
2081
EAVE
1601
5575 NAIL IN FENCE SITE TO BE FILLED TO MATCH NAIL IN FENCE
COMMUNICATIONS PIT RL 2.400 LEVEL 30.175 RL 2.400
RL 1.429
EAVE
STREET PARKING
COMMUNICATIONS POLE RL.1.68 RL.1.77
DRAINAGE
SPACE
D DRAINAGE MANHOLE
T
E
TO NEIGHBOURING PROPERTY.
DRAINAGE GRATE
EXISTING SLEEPER RETAINING
(HEIGHT TBC) RETAINING FILL
SITE TO BE FILLED TO MATCH
E ELECTRICITY MANHOLE PROPOSED RESIDENCE B 1.
7
NOTE: THIS SURVEY MAPS THE SITE FEATURES AND
5 LEVELS. IT DOES NOT GUARANTEE THE POSITION OF
FFL: 2.700
ELECTRICITY
ELECTRICITY PILLAR PEGS, ALLOTMENT BOUNDARIES OR FENCES. CHECK
LEVEL
1000 GRADE FILL FROM 2.4m AHD TO
TITLE FOR ANY EASEMENTS.
ELECTRICITY PIT SLAB TYPE: RAFT SLAB APPROX 1.75 AHD AT STREET LEVEL
SCREW IN KERB
LIGHT POLE SLAB HT: 300 RL 1.459 THE POSITION OF THE SEWER AND STORMWATER
S
NANNYGAI STREET
LINES, IF SHOWN, ARE APPROXIMATE ONLY & MAY
POWER POLE GL: 2.400 HAVE BEEN PLOTTED BY EITHER FIELD SURVEY OR
FROM RELEVANT SEWER/STORMWATER PLANS. THIS
TRAFFIC LIGHT
1.
FILL TO PAD INFORMATION NEEDS TO BE CONFIRMED BY THE
75
GM GAS METER BUILDER FROM AS-CONSTRUCTED OR COUNCIL
GAS
LEVEL OF 2.4m
1.75
E
T
GAS AHD DRAWINGS PRIOR TO CONSTRUCTION. IF THE SEWER
GAS VALVE LINE HASN'T BEEN SHOWN THE BUILDER IS REQUIRED
400
1000 1000
520 520
TO ACQUIRE THIS INFORMATION FROM AS-
SEWER S SEWER MANHOLE
6000
CONSTRUCTED OR COUNCIL DRAWINGS PRIOR TO
CONSTRUCTION.
400
FH FIRE HYDRANT
WATER
SERVICES SHOWN HEREON HAVE BEEN LOCATED
WM WATER METER WHERE POSSIBLE BY FIELD SURVEY OR PLOTTED
FROM THE RECORDS OF RELEVANT AUTHORITIES
WATER VALVE FILL REAR YARD
WHERE AVAILABLE. PRIOR TO ANY EXCAVATION OR
TO 2.4m AHD
PROPOSED RESIDENCE A
MISC.
SIGN POST CONSTRUCTION THE RELEVANT AUTHORITY SHOULD
BE CONTACTED FOR
S
1. E
SURVEY BENCHMARK FFL: 2.700 POSSIBLE LOCATION OF FURTHER UNDERGROUND
75
SERVICES.
SLAB TYPE: RAFT SLAB
T
SUBJECT LOT BOUNDARY 1000 WM
20.123 SLAB HT: 300 NOTE: WHEN BOUNDARIES ARE PLOTTED FROM
314°0'
ADJOINING LOT BOUNDARY
E
BUILDER SUPPLIED DISCLOSURE PLANS, THEY ARE
EASEMENT/LEASE BOUNDARY GL: 2.400 5790 SUBJECT TO SURVEY AND REGISTRATION WITH THE
1.50
STREET PARKING
DEPARTMENT OF ENVIRONMENT AND RESOURCE
BUILDING WALL COLUMN MANAGEMENT.
20.122
134°0'
BUILDING GUTTER/FASCIA/ROOF
SPACE
E
AHD LEVELS WERE GAINED BY GPS & AS SUCH IS
1.
FENCE
75
APPROXIMATE ONLY. THE LOCATION AND SIZING OF
TREES IS APPROXIMATE ONLY.
TOP/BOTTOM OF BANK RL.1.72
CHANGE OF GRADE RL.1.87 5575
EAVE
A FLOOD SEARCH HAS NOT BEEN COMPLETED ON
WALL
HOOD
1601
TIMBER RETAINING UP TO 800MM HIGH 224°0'
2081
NAIL IN FENCE
1081
SW SW RL 2.400 THIS PROPERTY, CHECK COUNCIL FOR FLOOD
DRAINAGE EAVE 30.175 INFORMATION.
E E 5000
ELECTRICAL 6055
HOOD/EAVE
SCREW IN KERB
GAS GAS RL 1.532 THIS PLAN HAS BEEN PREPARED FOR THE PURPOSE
GAS WALL
S S SEWERAGE MINIMUM FFL @ RL. 2.700 TO 6000
WALL
OF ONE PROPERTYS DESIGNING AND SITING A NEW
DWELLING AND SHOULD NOT BE USED FOR ANY
T T TELECOMMUNICATIONS MEET FLOOD REQUIREMENTS POWER POLE
OTHER PURPOSE.
W W WATER
IMPORT FILL TO RL. 2.400 TO SUIT NOTE: REFER TO NOTES & CONDITIONS OF TENDER
DOCUMENT FOR FURTHER REFERENCE
UF Denotes Underside of Fascia/Eave
WHERE RETAINING WALLS ARE REQUIRED/PROVIDED,
TG Denotes Top of Gutter AG. DRAINS TO BE CONNECTED TO STORMWATER VIA
SIL PITS.
-
RP DESCRIPTION STORMWATER LAYOUT
S/W DRAIN LAYOUTS IS FOR INDICITIVE PURPOSES
PRELIMINARY APPROVED PLANS Lot No. 54 ONLY & WILL BE INSTALLED AS PER THE DRAINAGE
SITE PLAN MCU21/0015
SUB-CONTRACTORS DISCRETION
IMPORTANT NOTE Scale 1 : 200 Description. RP76937 SWD TO BE 100mm DIAMETER PVC
NOOSA COUNCIL
THE SITING IS SUBJECT TO ADDITIONAL INFORMATION 30 APRIL 2021
Council NOOSA SHIRE TERMITE TREATMENT REQUIRED
PROVIDE TERMITE TREATMENT IN ACCORDANCE
BEING OBTAINED INCLUDING BUT NOT LIMITED TO THE - Site Area 607m2 WITH AS3660.
FOLLOWING:
DRAINAGE NOTES
·SITE SURVEY INFORMATION INCLUDING ADJOINING
SITE COVERAGE (A) ·SITE DRAINAGE SHALL COMPLY WITH NCC 3.1.2 '
GARAGE WALL
DRAINAGE' AND AS 3500 PLUMBING AND DRAINAGE
NEIGHBOURS DETAILS CODE
Site Area 303.50 m²
RL 2.520
·GRADE SURFACE AWAY FROM FOOTINGS AT 1:20
·CLEAR COPY OF APPROVED TITLE (INCLUDING FULL COPY PRELIMINARY SITE PLAN NOTES
BOUNDARY
MIN FALL
OF SECTION 32 AND ANY DEALINGS ON TITLE) Floor Area 121.39 m²
RL 1.700
·PROVIDE CUT TOE OR SPOON DRAINS AS
RL 1.360
THIS SITING IS SUBJECT TO THE FOLLOWING
Coverage 39.99% NECESSARY TO COLLECT AND CHANNEL WATER RUN-
ROAD
·EASEMENT DETAILS -SOIL REPORT & SURVEY OFF AWAY FROM THE BUILDING DURING
-CLEAR COPY OF TITLE CONSTRUCTION
·FALL OF LAND, INCLUDING ALL RES-CODE REQUIREMENTS. -EASEMENT DETAILS (IF APPLICABLE)
1500 3000 1500 5011 1500
SITE COVERAGE (B) ·TEMPORARY DOWNPIPES CONNECTED TO THE
CHANGES TO THE SITING (INCLUDING, WITHOUT LIMITATION, -FALL OF LAND STORMWATER SYSTEM SHALL BE INSTALLED AS
ROLL 1 in 6 GRADIENT 1 in 6 APPROX 3% RISE 1 in 8 SOON AS THE ROOF CLADDING IS
SIZE AND SETBACK OF HOME) MAY OCCUR. -RES-CODE REQUIREMENTS OVER GRADIENT GRADIENT Site Area 303.50 m² COMPLETED. FROM TIME TO TIME TEMPORARY
-DEVELOPER APPROVAL (IF APPLICABLE) 6000 6511 DOWNPIPES MAY BE EXCLUDED OR REMOVED FOR
CHANGES REQUIRED BY THE DEVELOPER AND RELEVANT -COUNCIL BUILDING REGULATIONS Floor Area OPERATIONAL REASONS.
AUTHORITIES ARE BEYOND ONE PROPERTYS
120.53 m²
·ALL STORMWATER DRAINS SHALL BE DIRECTED TO
DRIVEWAY GRADIENT PROFILE
CONTROL. ONE PROPERTY RESERVES THE RIGHT TO IMPORTANT NOTE: SITING MAY ALTER TO SUIT Coverage 39.71% THE COUNCIL NOMINATED LEGAL POINT OF
DISCHARGE
AMEND THE SITING AS REQUIRED.
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS SITE PLAN
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 22/04/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
As indicated Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
E 22/04/21 CERTIFIER AMENDMENTS NT/DW
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
E
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 1 Revision:
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 10 (of 13)
Page 2
ROOF WATER TO KERB
DP DP DP
1.
7 5
5.00°
5.00°
5.00°
1.
75
1.75
DP DP DP
ROOF WATER TO KERB
DP DP DP
5.00°
1.
75
5.00°
5.00°
1.50
DP DP DP
1.
75
ROOF WATER TO KERB
-
PRELIMINARY APPROVED PLANS
MCU21/0015
NOOSA COUNCIL
30 APRIL 2021
-
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS ROOF/STORMWATER
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 22/04/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
1 : 100 Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
E 22/04/21 CERTIFIER AMENDMENTS NT/DW
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
E
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 1A Revision:
Page 3
-
PRELIMINARY APPROVED PLANS
1200 4855 2400 20520 200 1000
MCU21/0015
NOOSA COUNCIL 300 5340 1240 3560 200 800 200
30 APRIL 2021
-
1081
CRAZY PAVE HINGED
1000
PATH GATE
POOL
LETTERBOX IN
5200
4.2X3.6
RENDERED
1680
BLOCK WALL
3385
200
EXPOSED
AGGREGATE
DRIVEWAY
ELECTRIC GATE
5900
4861
SITE AREA: 607.00m2 TURF
MINIMUMS:
LANDSCAPING:
40% OF SITE = 242.80m2 PAINTED AC
CONCRETE
SOFT LANDSCAPING:
400
1800H TIMBER FENCE
8796
60% OF LANDSCAPING = 145.68m 2
PAINTED
AC
CONCRETE
ACHIEVED:
LANDSCAPING: 248.02m2
ELECTRIC GATE
SOFT LANDSCAPING: 153.51m2
TURF
4861
6300
EXPOSED
AGGREGATE
200
DRIVEWAY
3379
1680
5200
POOL LETTERBOX IN
4.2X3.6 RENDERED
BLOCK WALL
CRAZY PAVE
1000
PATH HINGED
GATE
1081
RETAINING UP TO 800MM HIGH
1800H TIMBER FENCE ABOVE
4470 2110 3560 200 800 200
1200 4855 2400 20520 200 1000
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS LANDSCAPING
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 22/04/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
1 : 100 Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
E 22/04/21 CERTIFIER AMENDMENTS NT/DW
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
E
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 1C Revision:
Page 4
IMPORTANT NOTE: FOR ALL POST & BEAM
SETOUTS, REFER TO CONSTRUCTION DETAILS
IMPORTANT NOTE: ALL EXHAUST FANS TO BE B
DUCTED EXTERNALLY TO EAVE/SOFFIT
IMPORTANT NOTE: PROVIDE STUDS AT 300MM C A
OFF BACK WALL ADJACENT TO OVERHEAD
CUPBOARDS AND ALL SHELVING TO ALLOW D
FOR SIDE FIXING
PROVIDE TERMIMESH PROTECTION
18120 210
ALL WINDOWS TO BE @ 2400MM HEAD HEIGHT
UNLESS NOTED OTHERWISE
90 3510 90 6110 90 2140 6000 90
LIVING/DINING/KITCHEN LAUNDRY GARAGE
1090 960 90
HOUSE TYPE A
1750 4360
ALFRESCO 25.13 m²
HWS AC
BALCONY 37.30 m² DP DP FW0424 1100 SILL QH2408 DP
90
90
490
GARAGE 45.24 m² P'TRY WO
790
REF
740
LAUNDRY
MW
LOWER LIVING 51.60 m²
1500
820 CSD*
17
KITCHEN
2190
180MM STEP
UPPER LIVING 89.29 m² 16
POCKET DOOR
TIMBER 15
SSD2421
90 860 90
248.56 m² 14
LIFT P.
13 LIFT
720*
SECTIONAL PANEL
24-48 FLUSH FIT
12 PROV.
LIVING/DINING/KITCHEN
LIFT DOOR
11
GARAGE
800
5500
GARAGE
10
5830
DINING 9 EPOXY
180 STEPDOWN
TIMBER 8
6980
6800
ALFRESCO 7
6100
6
2470
TILES AHD. 2.700 AHD. 2.520
GYPROCK LINED 5
1 2800MM CEILING HT 2980MM CEILING HT 1
LINE OF BALCONY OVER
CEILING 4
SSD2432
3
4 4
LIVING
3810
40MM FALL
820 90
TIMBER 1 2
90
IMPORTANT NOTE: 60MM STEP
90
PDR PS
1300
1480
720*
90 880
• ALL EXHAUST FANS TO BE DUCTED EXTERNALLY TO THE
970
590
EAVE/SOFFIT. FW2110 LINE OF FLOOR OVER
90
90
90
• FOR ALL POST & BEAM SET OUTS, REFER TO DP PS DP DP SA0409
CONSTRUCTION DETAILS. 65 280 345
• PROVIDE STUDS AT 300mm OFF BACK WALL ADJACENT
TO OVERHEAD CUPBOARDS & SHELVING TO ALLOW FOR EXTERNAL SHOWER CRAZY PAVE TO ENTRY WITH LINE OF HOOD OVER
SIDE FIXING 'NATURAL' EDGE. TIMBER FLOORING
3100 90 1200 90 TO BE CUT AROUND
• ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE
SLIP RESISTANT IN ACCORDANCE WITH NCC TABLE
3.9.1.1 6110 1090 90 910 90 6050 90
• ALL DOORS TO WC, POWDER ROOM & ENSUITE WC TO LIVING/DINING/KITCHEN
BE FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH 90 3510 90 7200 1410 90 5070 90 600 90
NCC 3.8.3
ALFRESCO PDR
• HARDWIRED INTERCONNECTED SMOKE DETECTOR TO
BE LOCATED @ MIN. 300mm FROM BULKHEADS/WALLS 3600 8880 5070 780
WITH BATTERY BACK UP as per NCC 3.7.2 & to comply with
AS3786.
ENERGY EFFICIENCY TO COMPLY WITH NCC 3.12 (ENERGY
RATING OF 6.0 STARS).
SINGLE STOREY:
GROUND FLOOR A
• WALL SISALATION AND R1.5 BATTS TO EXT WALLS Scale 1 : 100
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE &
ALFRESCO)
-
• CEILING FAN TO ALFRESCO
GENERAL NOTES:
• 2X ROOF VENTILATORS PRELIMINARY APPROVED PLANS
• 3X VENTED EAVE SHEETS * DENOTES 2340H INTERNAL DOORS
2340H INTERNAL DOORS TO GROUND FLOOR
ONLY & WINDOW HEAD HEIGHTS 2143mm
FLOOR WASTE LOCATION
SMART WASTE INSERT TILE GRATE LOCATION MCU21/0015
(UNLESS NOTED OTHERWISE)
DOUBLE STOREY:
HARDWIRED INTERCONNECTED SMOKE G GAS POINT NOOSA COUNCIL
• WALL SISALATION AND R1.5 BATTS TO GROUND & FIRST
FLOOR
DETECTOR(S) TO BE LOCATED @ MIN. 300mm
FROM BULKHEADS/WALLS WITH BATTERY
BACKUP as per BCA 3.7.2 & to comply with
CAPPED COLD WATER POINT TO FRIDGE SPACE. REFER 30 APRIL 2021
-
TO DETAIL.
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE & AS3786 F
ALFRESCO) ASSUMES LIGHT COLOUR WINDOW *EDB DENOTES ENGINEER DESIGNED BEAM. RV ROOF VENTILATOR LOCATION
(REFER TO ENGINEERS DETAILS)
COVERINGS BY OWNER & LIGHT COLOUR ROOF AT TIME
x ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE SLIP
OF CONSTRUCTION. MH MANHOLE LOCATION RESISTANT IN ACCORDANCE WITH BCA TABLE 3.9.1.1
• CEILING FAN TO ALFRESCO DP DOWNPIPE LOCATION x DOORS TO WC, POWDER ROOM, WC & ENSUITE WC, TO BE
• 2X ROOF VENTILATORS FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH B.C.A. 3.8.3
AC DUCT LOCATION (GENERALLY 300mm
• 3X VENTED EAVE SHEETS DIA.)
HOUSE TYPE A
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS GROUND FLOOR
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 22/04/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
As indicated Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
E 22/04/21 CERTIFIER AMENDMENTS NT/DW
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
E
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 2 Revision:
Page 5
IMPORTANT NOTE: FOR ALL POST & BEAM
SETOUTS, REFER TO CONSTRUCTION DETAILS
IMPORTANT NOTE: ALL EXHAUST FANS TO BE B
DUCTED EXTERNALLY TO EAVE/SOFFIT
IMPORTANT NOTE: PROVIDE STUDS AT 300MM C A
OFF BACK WALL ADJACENT TO OVERHEAD
CUPBOARDS AND ALL SHELVING TO ALLOW D
FOR SIDE FIXING
PROVIDE TERMIMESH PROTECTION
ALL WINDOWS TO BE @ 2400MM HEAD HEIGHT 18120 210
UNLESS NOTED OTHERWISE
90 6610 90 7210 90 3940 90
BALCONY BED 1
1000 2010 90 1000 90 960 90 880 90 1000
HOUSE TYPE A VOID LIFT P. VOID
300 300 5115
ALFRESCO 25.13 m²
460
DP DP SA0816 SA0816 SA0816 DP
BALCONY 37.30 m²
170
90
90
590
GARAGE 45.24 m²
1000
90 1000
HALLWAY
820*
2700MM CEILING HT
820-08SL*
TIMBER
LOWER LIVING 51.60 m² 17
2330
QL2136/4 2700HH
16
UPPER LIVING 89.29 m²
SERVICES
720*
15
BALCONY
VOID
VOID
14
1360
1360
40MM STEP
BED 1
BED 1
3720
248.56 m² TILES 13 LIFT
CARPET
VOID
VOID PROV.
2420
12
SERVICES
5960
GYPROCK LINED
90 600 90
90 510 90
11
820*
5500
VOID
CEILING
VOID
10
ROBE
90 1000
720*
R
9
BALCONY
8
6980
5800
6800
820 CSD* 7
90
6
5
450
1 1
ROBE
ROBE
1400
4
BATH
2620
1400
3
4 4
BED 2
950
WIR
BED 2
BATH
3660
90
BED 3 CARPET
BED 3
3290
TILES 2 820 CSD*
CARPET
700 90
90
90
ENS
BATH
890 180
1800
1500
ENS
IMPORTANT NOTE: TILES
1300
1480
SHR
800
590
• ALL EXHAUST FANS TO BE DUCTED EXTERNALLY TO THE
EAVE/SOFFIT.
90
90
DP SA0816 SA0824 SA0824 SA0612
• FOR ALL POST & BEAM SET OUTS, REFER TO DP DP
1000
CONSTRUCTION DETAILS. 670 1545 2390 945
• PROVIDE STUDS AT 300mm OFF BACK WALL ADJACENT
TO OVERHEAD CUPBOARDS & SHELVING TO ALLOW FOR
SIDE FIXING
• ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE 410 90 910 90 51090 3010 1930 90 1000 800 90 3050
SLIP RESISTANT IN ACCORDANCE WITH NCC TABLE
V. R. ROBE WIR
3.9.1.1 90 120
• ALL DOORS TO WC, POWDER ROOM & ENSUITE WC TO 90 4510 90 2200 90 2820 90 1000 90 3020 90 2720 180 1040 90
BE FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH BALCONY BED 3 HALL BED 2 ENS SHR
NCC 3.8.3 4120 1000
• HARDWIRED INTERCONNECTED SMOKE DETECTOR TO
BE LOCATED @ MIN. 300mm FROM BULKHEADS/WALLS
WITH BATTERY BACK UP as per NCC 3.7.2 & to comply with
AS3786.
ENERGY EFFICIENCY TO COMPLY WITH NCC 3.12 (ENERGY
RATING OF 6.0 STARS).
FIRST FLOOR A
SINGLE STOREY: Scale 1 : 100
• WALL SISALATION AND R1.5 BATTS TO EXT WALLS
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE &
ALFRESCO) -
•
•
CEILING FAN TO ALFRESCO
2X ROOF VENTILATORS
GENERAL NOTES: PRELIMINARY APPROVED PLANS
• 3X VENTED EAVE SHEETS * DENOTES 2340H INTERNAL DOORS
2340H INTERNAL DOORS TO GROUND FLOOR
ONLY & WINDOW HEAD HEIGHTS 2143mm
FLOOR WASTE LOCATION
MCU21/0015
NOOSA COUNCIL
SMART WASTE INSERT TILE GRATE LOCATION
(UNLESS NOTED OTHERWISE)
DOUBLE STOREY:
G
30 APRIL 2021
HARDWIRED INTERCONNECTED SMOKE GAS POINT
• WALL SISALATION AND R1.5 BATTS TO GROUND & FIRST DETECTOR(S) TO BE LOCATED @ MIN. 300mm
FLOOR FROM BULKHEADS/WALLS WITH BATTERY
BACKUP as per BCA 3.7.2 & to comply with
CAPPED COLD WATER POINT TO FRIDGE SPACE. REFER
-
TO DETAIL.
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE & AS3786 F
ALFRESCO) ASSUMES LIGHT COLOUR WINDOW DENOTES ENGINEER DESIGNED BEAM. RV ROOF VENTILATOR LOCATION
*EDB (REFER TO ENGINEERS DETAILS)
COVERINGS BY OWNER & LIGHT COLOUR ROOF AT TIME
x ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE SLIP
OF CONSTRUCTION. MH MANHOLE LOCATION RESISTANT IN ACCORDANCE WITH BCA TABLE 3.9.1.1
• CEILING FAN TO ALFRESCO DP DOWNPIPE LOCATION x DOORS TO WC, POWDER ROOM, WC & ENSUITE WC, TO BE
• 2X ROOF VENTILATORS FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH B.C.A. 3.8.3
AC DUCT LOCATION (GENERALLY 300mm
• 3X VENTED EAVE SHEETS DIA.)
HOUSE TYPE A
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS FIRST FLOOR
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 22/04/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
As indicated Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
E 22/04/21 CERTIFIER AMENDMENTS NT/DW
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
E
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 2A Revision:
Page 6
IMPORTANT NOTE: FOR ALL POST & BEAM
SETOUTS, REFER TO CONSTRUCTION DETAILS
IMPORTANT NOTE: ALL EXHAUST FANS TO BE B
DUCTED EXTERNALLY TO EAVE/SOFFIT
IMPORTANT NOTE: PROVIDE STUDS AT 300MM C A
OFF BACK WALL ADJACENT TO OVERHEAD
CUPBOARDS AND ALL SHELVING TO ALLOW D
FOR SIDE FIXING
PROVIDE TERMIMESH PROTECTION
ALL WINDOWS TO BE @ 2400MM HEAD HEIGHT
UNLESS NOTED OTHERWISE 3600 8880 5640 1000
90 3510 90 7200 90 1410 90
HOUSE TYPE B ALFRESCO PDR
150
6110 90 1000 910 90 5810 90 90
LIVING/DINING/KITCHEN
ALFRESCO 25.13 m²
3100 90 1200 90
CRAZY PAVE TO ENTRY WITH
BALCONY 37.30 m² 'NATURAL' EDGE. TIMBER FLOORING
TO BE CUT AROUND
GARAGE 44.38 m² EXTERNAL SHOWER
65 280 345
LOWER LIVING 51.60 m² DP 1200 PVT * SA0409
DP PS DP
UPPER LIVING 89.29 m²
90
90
880 90
FW2110 LINE OF FLOOR OVER
590
720*
247.70 m²
LINE OF BALCONY OVER
PDR
90
PS
90 820
LIVING 1 2
SSD2432
3810
TIMBER
40MM FALL
LIVING/DINING/KITCHEN
3
LINE OF HOOD OVER
AHD. 2.700 4 AHD. 2.520
2470
2800MM CEILING HT 2980MM CEILING HT
6100
60MM STEP 5
SECTIONAL PANEL
ALFRESCO
24-48 FLUSH FIT
6
6980
6800
1 TILES 1
LIFT DOOR
7
GARAGE
GYPROCK LINED 960 2900 DINING 8
5830
4A CEILING TIMBER 9 4A
GARAGE
800
10
EPOXY
90 860 90
POCKET DOOR
11
180 STEPDOWN
IMPORTANT NOTE:
SSD2421
720*
900
12 LIFT
13 PROV.
• ALL EXHAUST FANS TO BE DUCTED EXTERNALLY TO THE 14
90
820 CSD*
15
EAVE/SOFFIT.
KITCHEN
1000
2190
16
• FOR ALL POST & BEAM SET OUTS, REFER TO TIMBER
1500
1500
17
CONSTRUCTION DETAILS. 180MM STEP
• PROVIDE STUDS AT 300mm OFF BACK WALL ADJACENT WO
740
790
600
REF
600
TO OVERHEAD CUPBOARDS & SHELVING TO ALLOW FOR P'TRY MW
90
90
SIDE FIXING DP DP FW0424 1100 SILL QH2408 DP
• ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE HWS AC
SLIP RESISTANT IN ACCORDANCE WITH NCC TABLE
3.9.1.1
1750 4360
• ALL DOORS TO WC, POWDER ROOM & ENSUITE WC TO
BE FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH 1090 960 90
NCC 3.8.3
• HARDWIRED INTERCONNECTED SMOKE DETECTOR TO
BE LOCATED @ MIN. 300mm FROM BULKHEADS/WALLS 90 3510 90 6110 90 2140 6000 90
WITH BATTERY BACK UP as per NCC 3.7.2 & to comply with ALFRESCO LIVING/DINING/KITCHEN LAUNDRY GARAGE
AS3786. 18120
ENERGY EFFICIENCY TO COMPLY WITH NCC 3.12 (ENERGY
RATING OF 6.0 STARS).
SINGLE STOREY: GROUND FLOOR B
• WALL SISALATION AND R1.5 BATTS TO EXT WALLS
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE &
Scale 1 : 100
-
ALFRESCO)
• CEILING FAN TO ALFRESCO
GENERAL NOTES: PRELIMINARY APPROVED PLANS
• 2X ROOF VENTILATORS
• 3X VENTED EAVE SHEETS * DENOTES 2340H INTERNAL DOORS
2340H INTERNAL DOORS TO GROUND FLOOR
FLOOR WASTE LOCATION
MCU21/0015
ONLY & WINDOW HEAD HEIGHTS 2143mm
(UNLESS NOTED OTHERWISE)
SMART WASTE INSERT TILE GRATE LOCATION
NOOSA COUNCIL
DOUBLE STOREY:
• WALL SISALATION AND R1.5 BATTS TO GROUND & FIRST
HARDWIRED INTERCONNECTED SMOKE
DETECTOR(S) TO BE LOCATED @ MIN. 300mm
G GAS POINT
30 APRIL 2021
FLOOR FROM BULKHEADS/WALLS WITH BATTERY
BACKUP as per BCA 3.7.2 & to comply with
CAPPED COLD WATER POINT TO FRIDGE SPACE. REFER
TO DETAIL.
-
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE & AS3786 F
ALFRESCO) ASSUMES LIGHT COLOUR WINDOW DENOTES ENGINEER DESIGNED BEAM. RV ROOF VENTILATOR LOCATION
*EDB (REFER TO ENGINEERS DETAILS)
COVERINGS BY OWNER & LIGHT COLOUR ROOF AT TIME
x ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE SLIP
OF CONSTRUCTION. MH MANHOLE LOCATION RESISTANT IN ACCORDANCE WITH BCA TABLE 3.9.1.1
• CEILING FAN TO ALFRESCO DP DOWNPIPE LOCATION x DOORS TO WC, POWDER ROOM, WC & ENSUITE WC, TO BE
• 2X ROOF VENTILATORS FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH B.C.A. 3.8.3
AC DUCT LOCATION (GENERALLY 300mm
• 3X VENTED EAVE SHEETS DIA.)
HOUSE TYPE B
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS GROUND FLOOR
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 22/04/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
As indicated Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
E 22/04/21 CERTIFIER AMENDMENTS NT/DW
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
E
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 2B Revision:
Page 7
IMPORTANT NOTE: FOR ALL POST & BEAM
SETOUTS, REFER TO CONSTRUCTION DETAILS
IMPORTANT NOTE: ALL EXHAUST FANS TO BE B
DUCTED EXTERNALLY TO EAVE/SOFFIT
IMPORTANT NOTE: PROVIDE STUDS AT 300MM C A
OFF BACK WALL ADJACENT TO OVERHEAD
CUPBOARDS AND ALL SHELVING TO ALLOW D
FOR SIDE FIXING
PROVIDE TERMIMESH PROTECTION
ALL WINDOWS TO BE @ 2400MM HEAD HEIGHT
UNLESS NOTED OTHERWISE
HOUSE TYPE B
ALFRESCO 25.13 m² 90 4510 90 2200 90 2820 90 1000 90 3020 90 2720 180 1040 90
BALCONY BED 3 BED 2 SHR
BALCONY 37.30 m²
410 90 910 90 51090 3010 1930 90 1000
GARAGE 44.38 m² R ROBE
LOWER LIVING 51.60 m²
UPPER LIVING 89.29 m² 670 1665 2270 945
247.70 m² SA0816 DP SA0824 DP SA0824 SA0612
DP
90
90
590
SHR
NIB
800
180 890
1500
ENS
BATH
ENS
1800
TILES
90 700
BED 3
3290
BED 3
BED 2
3660
820 CSD*
BATH BED 2
90
CARPET
WIR
950
TILES CARPET
1400
WIR
1200 MSD
2620
ROBE
ROBE
1400
450
BALCONY
90
6800
5800
6980
6980
1 TILES 1
1000 90
820 CSD*
90510 90
GYPROCK LINED
SERVICES
IMPORTANT NOTE:
90 600 90
720*
4A CEILING 4A
VOID
VOID
R.
ROBE
• ALL EXHAUST FANS TO BE DUCTED EXTERNALLY TO THE 820*
VOID
VOID
2420
EAVE/SOFFIT.
SERVICES
LIFT
BED 1
QL2127/3
• FOR ALL POST & BEAM SET OUTS, REFER TO
3720
VOID
1360
VOID
1360
PROV.
CONSTRUCTION DETAILS. BED 1
720*
• PROVIDE STUDS AT 300mm OFF BACK WALL ADJACENT CARPET
820-08SL*
40MM STEP
2375
TO OVERHEAD CUPBOARDS & SHELVING TO ALLOW FOR
1000 90
SIDE FIXING
HALLWAY
1000
• ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE
820*
TIMBER 2700MM CEILING HT
SLIP RESISTANT IN ACCORDANCE WITH NCC TABLE
590
430
3.9.1.1
90
90
• ALL DOORS TO WC, POWDER ROOM & ENSUITE WC TO DP DP DP
SA0816 SA0816 SA0816
BE FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH 300 300 5115
NCC 3.8.3
• HARDWIRED INTERCONNECTED SMOKE DETECTOR TO
1000 2010 90 800 90
960 90 880 90 1000 90 3050
BE LOCATED @ MIN. 300mm FROM BULKHEADS/WALLS
VOID LIFT P. VOID WIR
WITH BATTERY BACK UP as per NCC 3.7.2 & to comply with
AS3786. 90 6610 90 7210 3940
3940 90
BED 1
ENERGY EFFICIENCY TO COMPLY WITH NCC 3.12 (ENERGY
RATING OF 6.0 STARS).
SINGLE STOREY: FIRST FLOOR B
• WALL SISALATION AND R1.5 BATTS TO EXT WALLS Scale 1 : 100
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE & -
ALFRESCO)
• CEILING FAN TO ALFRESCO PRELIMINARY APPROVED
GENERAL NOTES:
• 2X ROOF VENTILATORS PLANS
• 3X VENTED EAVE SHEETS * DENOTES 2340H INTERNAL DOORS
2340H INTERNAL DOORS TO GROUND FLOOR
ONLY & WINDOW HEAD HEIGHTS 2143mm
FLOOR WASTE LOCATION
SMART WASTE INSERT TILE GRATE LOCATION MCU21/0015
(UNLESS NOTED OTHERWISE)
DOUBLE STOREY:
HARDWIRED INTERCONNECTED SMOKE G GAS POINT NOOSA COUNCIL
• WALL SISALATION AND R1.5 BATTS TO GROUND & FIRST
30 APRIL 2021
DETECTOR(S) TO BE LOCATED @ MIN. 300mm
FLOOR FROM BULKHEADS/WALLS WITH BATTERY
BACKUP as per BCA 3.7.2 & to comply with
CAPPED COLD WATER POINT TO FRIDGE SPACE. REFER
TO DETAIL.
F
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE & AS3786
-
ALFRESCO) ASSUMES LIGHT COLOUR WINDOW *EDB DENOTES ENGINEER DESIGNED BEAM. RV ROOF VENTILATOR LOCATION
(REFER TO ENGINEERS DETAILS)
COVERINGS BY OWNER & LIGHT COLOUR ROOF AT TIME
x ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE SLIP
OF CONSTRUCTION. MH MANHOLE LOCATION RESISTANT IN ACCORDANCE WITH BCA TABLE 3.9.1.1
• CEILING FAN TO ALFRESCO DP DOWNPIPE LOCATION x DOORS TO WC, POWDER ROOM, WC & ENSUITE WC, TO BE
• 2X ROOF VENTILATORS FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH B.C.A. 3.8.3
AC DUCT LOCATION (GENERALLY 300mm
• 3X VENTED EAVE SHEETS DIA.)
HOUSE TYPE B
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS FIRST FLOOR
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 22/04/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
As indicated Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
E 22/04/21 CERTIFIER AMENDMENTS NT/DW
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
E
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 2C Revision:
Page 8
GENERAL NOTES
• ALL FIRST FLOOR WINDOWS TO BE
RESTRICTED TO A MAXIMUM 125MM
OPENING
8440 • DOORS TO WC, POWDER ROOM WC, &
HOOD ENSUITE WC TO BE FITTED WITH LIFT
1000 405MM STRIA CLADDING RENDERED EPS FOAM OFF HINGES IN ACCORDANCE WITH
(OR SIMILAR) FIXED TO CLADDING TO WINDOW
STUDWORK HOOD B.C.A. 3.8.3
• WINDOW HEAD HEIGHT DIMESIONS TO
BE TAKEN TO THE NEAREST BRICK
COURSE (UNLESS NOTED OTHERWISE)
425
• ALL GLAZING TO COMPLY WITH A.S.
1288-2006 (Amdt 1-2008) (REFER TO
ENERGY RATING FOR ALL GLAZING
VALUES.)
• FOAM SYSTEM REFER TO ATTACHED
HOOD
3450
2700
SPECIFICATIONS (WHERE APPLICABLE)
STONE CLAD COLUMN
7132
FIRST FLOOR
325
5800
2800
2980
GROUND FLOOR
180
GARAGE
PROPOSED FILL
NATURAL GROUND LEVEL
-
BATTENS FIXED TO EASYLINE PRELIMINARY APPROVED PLANS
ELEVATION A STONEWORK FIXED TO
EASYLAP CLADDING
CLADDING AND FLUSH FIT
SECTIONAL DOOR MCU21/0015
Scale 1 : 100 5120 NOOSA COUNCIL
HOOD 30 APRIL 2021
COLORBOND ROOF 1000 -
SHEETING, FASCIA, AND -
GUTTER
5.00° 8M HEIGHT LINE
450
405MM STRIA CLADDING
(OR SIMILAR) FIXED TO
2700
400MM AXON CLADDING STUDWORK
FIXED TO STUDWORK
RENDERED EPS FOAM
CLADDING TO WINDOW
FIRST FLOOR HOOD
325
405MM STRIA CLADDING
1000
(OR SIMILAR) FIXED TO
STUDWORK
2800
EPS/HEBEL CLADDING TO STONEWORK FIXED TO
1800
ALFRESCO EASYLAP CLADDING
GROUND FLOOR
60
GARAGE
NATURAL GROUND LEVEL
ELEVATION B
Scale 1 : 100 PROPOSED FILL
HOUSE TYPE A
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS ELEVATIONS A & B
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 09/03/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
1 : 100 Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
D
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 3 Revision:
Page 9
GENERAL NOTES
• ALL FIRST FLOOR WINDOWS TO BE
RESTRICTED TO A MAXIMUM 125MM
OPENING
• DOORS TO WC, POWDER ROOM WC, &
ENSUITE WC TO BE FITTED WITH LIFT
DOWNPIPE DROPPER
450 450 OFF HINGES IN ACCORDANCE WITH
B.C.A. 3.8.3
• WINDOW HEAD HEIGHT DIMESIONS TO
5.00° 5.00° BE TAKEN TO THE NEAREST BRICK
DOWNPIPE DROPPER
COURSE (UNLESS NOTED OTHERWISE)
• ALL GLAZING TO COMPLY WITH A.S.
1288-2006 (Amdt 1-2008) (REFER TO
FEATURE FIBRO/COMPOSITE ENERGY RATING FOR ALL GLAZING
1600
CLADDING TO BALCONY
VALUES.)
• FOAM SYSTEM REFER TO ATTACHED
2700
400MM AXON CLADDING
(OR SIMILAR) FIXED TO
SPECIFICATIONS (WHERE APPLICABLE)
STUDWORK
1100
FIRST FLOOR
400 60
325
2800
2400
GROUND FLOOR
60
PROPOSED FILL
NATURAL GROUND LEVEL
STONEWORK FIXED TO
-
ELEVATION C EASYLAP CLADDING EPS/HEBEL CLADDING TO
ALFRESCO PRELIMINARY APPROVED PLANS
Scale 1 : 100 MCU21/0015
NOOSA COUNCIL
30 APRIL 2021
-
-
COLORBOND ROOF
SHEETING, FASCIA, AND
RAISED ROOF
GUTTER
500
425
2700
400MM AXON CLADDING
(OR SIMILAR) FIXED TO
STUDWORK
FIRST FLOOR
325
2800
405MM STRIA CLADDING
(OR SIMILAR) FIXED TO
HWS STUDWORK
AC
GROUND FLOOR
180
GARAGE
PROPOSED FILL
NATURAL GROUND LEVEL
ELEVATION D
Scale 1 : 100
HOUSE TYPE A
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS ELEVATIONS C & D
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 09/03/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
1 : 100 Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
D
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 3A Revision:
Page 10
GENERAL NOTES
• ALL FIRST FLOOR WINDOWS TO BE
RESTRICTED TO A MAXIMUM 125MM
OPENING
• DOORS TO WC, POWDER ROOM WC, &
ENSUITE WC TO BE FITTED WITH LIFT
6980 OFF HINGES IN ACCORDANCE WITH
HOOD B.C.A. 3.8.3
LASER CUT SCREENS
• WINDOW HEAD HEIGHT DIMESIONS TO
RENDERED EPS FOAM BE TAKEN TO THE NEAREST BRICK
CLADDING TO WINDOW HOOD COURSE (UNLESS NOTED OTHERWISE)
FF_CEILING • ALL GLAZING TO COMPLY WITH A.S.
305
1288-2006 (Amdt 1-2008) (REFER TO
ENERGY RATING FOR ALL GLAZING
VALUES.)
• FOAM SYSTEM REFER TO ATTACHED
SPECIFICATIONS (WHERE APPLICABLE)
2700
7132
FIRST FLOOR
325
6005
2800
2980
GROUND FLOOR
180
GARAGE
PROPOSED FILL
NGL
-
ELEVATION A PRELIMINARY APPROVED PLANS
Scale 1 : 100 BATTENS FIXED TO EASYLINE
CLADDING AND FLUSH FIT
MCU21/0015
SECTIONAL DOOR NOOSA COUNCIL
BATTENS TO EXTEND 1000MM FROM
WALL TO CREATE SCREENING 30 APRIL 2021
-
-
405MM STRIA CLADDING COLORBOND TRIMDEK
(OR SIMILAR) FIXED TO ROOF SHEETING,
8M HEIGHT LINE STUDWORK FASCIA, AND GUTTER
5.00°
RAISED ROOF
500
450
HOOD
2700
3330
400MM AXON CLADDING
(OR SIMILAR) FIXED TO
STUDWORK
FIRST FLOOR
325
2800
HWS
AC
GROUND FLOOR
GARAGE
NGL
ELEVATION B
Scale 1 : 100
PROPOSED FILL
HOUSE TYPE B
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS ELEVATIONS A & B
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 09/03/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
1 : 100 Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
D
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 3B Revision:
The text continues on page 11.
Used in these records
SUPERSEDED Approved Plans - MCU21-0015.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.