Original source · versioned page text
7.0 Site Surveys
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
3 B
SP197517 ru
c e
H
124
LEGEND:
123
ig
hw Road
Kerb Back
Kerb Invert
Terrain
Driveway
Footpath
12
3
ay Edge of Bitumen
Edge of Gravel
Slab Edge
Retaining Wall Base
t
123
r
Road Crown Retaining Wall Top
ou
122 Traffic Park Meter Change of Grade
Traffic Light Top of Bank
Traffic Pit Toe of Bank
12 Traffic Sign Waterline
rC
3 Traffic Post Box Garden Edge
12
2 Structures Creek Toe of Bank
2 3
Building Line Creek Top of Bank
1
2
Roof Ridgeline Creek Invert
12
ylo
Fence Line Creek Waterline
SP324340 Gate Tree
Hand Rail Tree Canopy
Ta 122 12 Cattle Grid Control Point/PSM
1 Bollard
12 Drainage
2
Sewer D(*) Drainage line
S(*) Sewer Line Open Drain
Valve Manhole
Inspection Opening Field Inlet
0
1
Manhole Downpipe
12
12
Electrical Communications
Communication Line
1
E(*) Electricity Line C(*)
12
12
W
1 Overhead Line TOH Overhead Line
121
W ((A EOH
A))
A) W
W ( Pits/Manholes Pits/Manholes
(A
119
) )) Pole Pillar
((AA
Street Light Gas
121
2
W
W
121 Light In-Ground G(*) Gas Line
118
W Water Valve
(A SP324340 W(*) Water Line Marker
0 )
(A
)
12 Meter
D (C)
W 0 Valve
SP309776 H Fire Hydrant
117 Tap Subsurface Utility -QL
0
12
) (A
) Sprinkler * (A) * Quality A (H±50mm,V±50mm)
(A Fuel * (B) * Quality B (H±300mm,V±500mm)
A)
W
* Quality C (H±300mm,2D)
S
S ( P(*) Fuel Line * (C)
D Fitting * (D) * Quality D (Exist Record)
0
(A
12
A)
9
S ( )
11
0 )
6
/
11
)
12
(A
(A
/
A) 120
S (
W
118
S
S (
A)
120
D
(A
)
3 NOTES:
)
)
(A (A
W
SP324340 1. Drawn to scale on an A3 sheet.
S
2. Contour Interval... 0.25m
7
12
11
/
D 0
3. All levels are in metres on the Australian Height
/
(A
) 9
) (
A)
11 6
Datum referred to PSM190989 - RL 120.402 AHD
11
(A
S W situated in Taylor Court, Cooroy.
9
)
4. All Boundaries are vide title and subject to
11
D (C H
(A D confirmation by survey.
)
8
11
/
5. The Location of Underground services are in
/
4 5
D )
accordance with AS5488:2019, the Australian
(A (A Standard for classification of Subsurface Utility
)
7
D
Information (SUI). The exact nature and location
11
4 0 of these services should be confirmed prior to
SP324340 12 119 construction.
6
D
11
)
/
(A
(A
6. Field Survey Completed on 5/7/2021
/
) D
11
9
)
9
D (C
11
8
D )
11
(A
(A
119
) D
119 119 119
115
/
119 119 119
7/
11
118 118
118
118
// 7 Level datum: AHD Derived (PSM190989)
6
// Horiz datum: MGA Derived DCDB (05/18)
11
118
117 117
// SP237587
117 // 117 Coord Origin: PSM (Form 6) (PSM190989)
// 116
4 GDA System: GDA94 Coordinate System: Plane 1:1
117 11
// //
// Meridian: DCDB
Title:
VERIFICATION PLOT
Lots 1-4 SP324340
Taylor Court, Cooroy
Client: Ejmont Nominees
Locality: Cooroy
Local Gov: Noosa Shire Council
Surveyed By: TD Approved: BMH
Scale 1:750 Date Created: 14/09/21 Scale: 1:750
File Ref: 180308
Plan No: 180308_018_DET Rev: A
0m 10 20 30 40 50 60 70 80 90
Page 1 of 5 A3
See the original