2.0 SITE AND SOIL EVALUATION

The field and officework undertaken for our site and soil evaluation consisted of

© a desk top study in accordance with the regulatory authority,

a comprehensive site assessment to record topography, geography and geology,
the confirmation of expected available areas and delineation of exclusion areas,
the assessment of site exposure and suitability,

a detailed subsoil investigation recording characteristics and limitations,

the determination of Soil Category, Colour, Texture, and Structure,

the determination of Indicative Drainage and Permeability,

soil observation boreholes (75-100mm dia. Jarret style hand augers),

the calculation of the Design Irrigation Rate (DIR),

the calculation of the Design Loading Rate (DLR),

the collation and evaluation of the results from the above studies.

BeBe Te Ge Ge Ge B_ eGo Go

(The test locations were not professionally surveyed and should be considered approximate)
(All fieldwork performed in accordance with the relevant Australian Standards and Codes)
(All boreholes backfilled in accordance with Occupational Health and Safety regulations)

The purpose of this site and soil evaluation is to ensure that suitable Land Application
Facilities are selected for this particular site.

In compiling this report we have assessed the existing and historical parameters to
gain a comprehensive overview of the potential for on-site domestic wastewater
management. The scale of, and methodology of our site and soil evaluation is
considered to be adequate, relative to, and indicative of the size of the facility, having
considered the consistent natural soil profile and the availability of suitable land.

      

re I)
Registerec air (QBCC 740251)
Unearthed Geotechnical P/L.

A full copy of this report and all the accompanying sketches plans details and notes shall be
made available to all present and future owners and or occupiers of the proposed cabins, and
future shed that are to be serviced by these Land Application Facilities, and to all
contractors/suppliers/installers for quotation and or construction objectives.

 

Unearthed Geotechnical P/L. 2 Design Report 022-164

Used in these records

About this file

File size
15.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

wastewater design.pdf · 15.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.