Council archive · source document
wastewater design · MCU22/0192
Very large file (15.0 MB): the original may take a few minutes to open or download. The page text below is quick to read.
4.1 Limitations. Our site and soil evaluation noted the following limitations which may have an adverse effect on the performance, serviceability, and sustainability of environmentally acceptable on-site domestic wastewater management « allotment size, configuration and topographic idiosyncrasies, e separation distance requirements, « areas of excessive slope, ° areas previously used or required for construction or landscaping, e poor permeability of sub soil profile. In formulating our recommendations we have noted, considered and made allowance for the effect these limitations will have on the performance, serviceability, and sustainability of on-site domestic wastewater management. We consider that in line with the recommendations set out within this report, and with appropriate control measures in position, sustainable on-site domestic wastewater treatment and disposal will be achieved. In consideration of these limitations and with reference to the Queensland Plumbing and Wastewater Code and AS/NZS1547-2012 On-site Domestic Wastewater Management, and with presumed compliance to the recommendations made in this report, for the Proposed Cabins we recommend advanced secondary treatment of all domestic wastewater flows for the efficient, sustainable and environmentally acceptable disposal of treated effluent. The use of such approved systems consequentially enables the 30m horizontal separation distance from the intermittent watercourses/dams to be reduced to 10m, and the vertical separation distance to be reduced to 300mm. In consideration of these limitations and with reference to the Queensland Plumbing and Wastewater Code and AS/NZS1547-2012 On-site Domestic Wastewater Management, and with presumed compliance to the recommendations made in this report, for the Future Shed we recommend primary treatment of all wastewater flows for the efficient, sustainable and environmentally acceptable conventional absorption trench/bed disposal of the treated effluent. Although we recorded no existing evidence of eutrification, we believe there is the potential for eutrification of any associated dam or watercourse if there is nutrient leakage from any disposal site. However, with the encouraged use of phosphate free cleaning products, we believe the reduced potential will be contained. Given the recorded slope may be viewed as a site constraint we recommend the installation of retention mounds/bunds (suggested minimum 1000mm wide and 150mm high) running across the slope to help with the confinement and retention of the applied effluent with the proposed Land Application Areas. Unearthed Geotechnical P/L. 6 Design Report 022-164
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
wastewater design.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.