Original source · versioned page text
Information Request MCU20 0142
Officer: Tara Norley Direct Telephone: 07 53296486 Our Reference: MCU20/0142 Your Reference: 20200275 17 December 2020 Integral Constructions Pty Ltd C/- Adapt Planning PO Box 7618 SIPPY DOWNS QLD 4556 [email protected] Dear Sir/Madam Information Request Planning Act 2016 I refer to your application and advise that Council requires further information to satisfactorily assess the proposal. application details Application No. MCU20/0142 Street Address: 64 Lorikeet Drive, Peregian Beach Qld 4573 Real Property Description: Lot 913 on P93121 Planning Scheme: Noosa Plan 2020 (25 September 2020) INFORMATION REQUIRED The information requested is set out below: Issue – Setbacks The eastern wall of the pool is located within the 6m rear boundary setback and is not cantilevered. Information Required Provide updated plans with the pool complying with the 6m rear setback requirement. Issue – Stormwater The submitted material does not include an indication of how stormwater runoff from the proposed development will be collected and controlled. It is noted that there is no downstream Council drainage system and it is expected that on-site infiltration will be required. Information Required Provide a stormwater management plan for the proposed development. The management plan must include but not be limited to: the structures for both the construction and operational phases of the development; be consistent with the site specific geotechnical report recommendations; demonstrate that the runoff from the site is suitably controlled to ensure that the downstream environment is not adversely affected or destabilized; demonstrate that the proposed works will not cause stormwater ponding on neighbouring properties nor on road reserve. Please note that the stormwater drainage system must be a gravity system and pumps are not acceptable. Issue - Access The submitted plans do not include sufficient detail on the driveway and access to the proposed garage. Information Required Provide additional detail on the driveway and access to the proposed garage. The detail must be prepared by a suitably qualified person and include but not be limited to: levels and grades of the access driveway; a longitudinal section extending from the centerline of the formation in Lorikeet Drive to the proposed garage; a driveway designed generally in accordance with Council’s standard drawings RS-049 and RS-050 and respective addendums; the necessary stormwater drainage structures; all vegetation, on road reserve, required to be cleared for access. due date for response to information request The due date for providing the requested information is 22 March 2021. Please advise Council of your response to this information request in accordance with section 13 of the Development Assessment Rules. If you do not provide a response before the due date, it will be taken as if you have decided not to respond to the information request and Council will continue with the assessment of your application. other details You can follow the progress of this application online at www.noosa.qld.gov.au. The “Online Services” page can be accessed via "Quick Links" on the left hand side of the screen. Should you have any further queries in relation to the above, please do not hesitate to contact me on the number above. Yours faithfully Tara Norley Development Planner [word/footer1.xml] Page 2 of 2 [word/footer2.xml] PO Box 141 P. (07) 5329 6500 [email protected] TEWANTIN QLD 4565 F. (07) 5329 6501 www.noosa.qld.gov.au Page 1 of 2 [word/header1.xml] 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.