Council archive · source document
AppendixC_FloodInformationCertificate · MCU16/0078
Attached to the e-mail MCU16/0078 - Development Application.
AMENDMENT TO PLANNING SCHEME FLOOD MAPPING Noosa Council intends to amend its planning scheme including changes to the flood hazard overlay mapping. These proposed amendments may affect the subject site. The proposed amendments are available online and at Council’s Chambers, 9 Pelican St Tewantin. CLIMATE CHANGE The advice provided in this certificate is based upon standards relating to current climatic conditions, historically recorded flood events and the predicted 1 % AEP under 2100 climate change conditions. Please be aware, the current standards do not include full allowances for future climate change projections in our region. These projections include but are not limited to; increased rainfall intensity, higher mean sea level and more extreme weather conditions (e.g. storm surge and tropical cyclones). NOTES FOR FLOOD INFORMATION 1. The absence of Highest Historical Flood Level information does not imply that the above property is not subject to flooding, simply that Council has no record of this property flooding. Applicants are encouraged to make their own local enquiries. 2. In accordance the self-assessable (detached) house code, the MINIMUM FLOOR LEVEL is calculated as whichever is greater of either: (a) 500mm freeboard added to the Defined Flood Level for the site; or (b) 800mm freeboard added to the Defined Flood Level for the site if the property is located in the Noosa River catchment only in accordance with the Noosa River Flood Study; or (c) 500mm freeboard added to the Highest Historical Flood Level appropriate to the site; or (d) If the property is intended for use as a Hospital, Aged Residential Care Facility or Emergency Services Facility then the Council should be contacted to determine this level. 3. Council advises that if stormwater drainage pipelines/easements exist on the property then no earthworks or building are permitted in the easement. 4. All buildings shall conform to the relevant Planning Scheme Code in The Noosa Plan. 5. Please be aware of the natural topography in your area. Water runoff which exceeds the capacity of the underground drainage system (if present) and which concentrates in surface depressions and gullies as it flows down a catchment can cause localised flooding and is not identified in this certificate. 6. Filling must not cause actionable nuisance in accordance with Queensland Urban Drainage Manual. 7. Council advises that if there are openings to basements these openings require a minimum level at least equal to the minimum floor level. 8. Please be aware that the reported flood information may vary in the future as new data becomes available. www.noosa.qld.gov.au [email protected] T 07 5329 6500 PO Box 141 Tewantin Qld 4565 ABN 97 969 214 121 Flood Information Certificate (FSCV3-0809) Page 2 of 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
AppendixC_FloodInformationCertificate.pdfRelated documentApplication case desk ↗
About this file
- File size
- 246 KB (small file)
- File type
No other editions are linked here.