W
N
PRECAST CONCRETE
HEADWALL AND ROCK
W
T
SCOUR PROTECTION
RL116.5
W
PROPOSED ROAD WIDENING
N
SERVICE STATION
EU
W
BIORETENTION BASIN
T
T
RL115.5
.5
S
12
WATER RETICULATION FOR FIRE
EXISTING SEWER FIGHTING PURPOSES
L1
SEWER RETICULATION
RETICULATION
FF
SEWER RISING MAIN
W
EU
LIVE CONNECTION TO EXISTING
W
RISING MAIN DISCHARGE SEWER CONNECTION
PR
T
SEWER MANHOLE BY N FH
EXISTING HEADWALL TO REMAIN
MANHOLE TO SEQ STD DWG FOR CAR WASH
T
UNITYWATER
IV
FH
No. SEQ-SPS-1406-1 CAR WASH WATER
S
SEWER RISING MAIN AT RL116.0 RL115.5 TREATMENT AND
E STORAGE
FUTURE
RO
W
EU
W
EXISTING SEWER RISING MAIN
AD
S
1
2
AD
T
RL110.5
RO
RL108.3
SELF STORAGE
W
E
STORMWATER
AT
DRAINAGE FOR
W
IV
S
FUTURE DEVELOPMENT
PR
RL110.3 BY OTHERS
EU
PRECAST CONCRETE
T
HEADWALL AND ROCK
W
SCOUR PROTECTION
FFL116.7
FH
RL112.0 RL111.4
W
RL110.1
S
FFL117.3
FFL117.0
SELF STORAGE
BIORETENTION BASIN PRECAST CONCRETE
W
T
HEADWALL AND ROCK
SCOUR PROTECTION
RL111.2 RL110.0
DETENTION BASIN
W
RL109.4
RL111.9 FUTURE DEVELOPMENT
BIORETENTION BASIN
FH
RL111.0 PRECAST CONCRETE
HEADWALL AND ROCK
W
SCOUR PROTECTION
S
SEWER CONNECTION
FOR SELF STORAGE RL111.7 SEWER CONNECTION
RL110.7 FOR TOURIST PARK AND
FH
FUTURE DEVELOPMENT
FFL111.4
TOURIST PARK RL110.0 PRECAST CONCRETE
HEADWALL AND ROCK
W
S
SCOUR PROTECTION
RL111.5
OFFICE FH
RL114.0
FFL112.5 WATER RETICULATION
RL110.4
TOURIST PARK
BIORETENTION BASIN
FOR FIRE FIGHTING
PURPOSES PRECAST CONCRETE
S
RL110.1 HEADWALL AND ROCK
SCOUR PROTECTION
EU RL112.3 RL109.5
W
EU
S
RL111.5
W
RL111.2
EU
RL110.4
S
E
WU RL110.1
RL109.5
EU
S
INSTALL ENVIROPOD BASKET OR
SIMILARLY APPROVED IN ALL
EU
STORMWATER INLETS. TYPICAL
SW EU
EU
EU
W
S
EU
W
S
EU
W
S
EU
EU
LAYOUT PLAN
SCALE 1:500
CLIENT: SCALE: AS SHOWN DRAWN: AvT PROJECT: JOB No.:
PROPOSED MIXED USE DEVELOPMENT
SHEET SIZE: A1 DESIGN: AvT
CNR. MYALL ST & FERRELLS RD COOROY QLD
14012
DATUM: AHD CHECKED: AvT
COPYRIGHT: THIS DOCUMENT IS AND SHALL REMAIN APPROVED: DRAWING TITLE: DRAWING No.: REV.:
0 5 10 20 25 THE PROPERTY OF vT CONSULTING ENGINEERS. THIS
PRELIMINARY SERVICES
A: PO Box 26, Carina QLD 4152
A
DOCUMENT MAY ONLY BE USED FOR THE PURPOSE
A 23.05.14 ORIGINAL ISSUE AvT AvT E: [email protected]
FOR WHICH IT WAS COMMISSIONED AND IN
ACCORDANCE WITH THE TERMS OF ENGAGEMENT. KHUZAINI SANI P004
SCALE 1:500
REV. DATE: AMENDMENT: BY: APP: W: vtce.com.au UNAUTHORISED USE OF THIS DOCUMENT IN ANY
RPEQ: 10697 DATE: 23.05.14 LAYOUT PLAN - SHEET 2 NOT FOR CONSTRUCTION