Log in to see the plans as drawn Oil Capture and Containment
High Risk
SITE Ararat Wind Farm, VIC.
Ararat Wind Farm APPLICATION Transformers
RISK High
POLLUTANTS Transformer oil
DISCHARGE Stormwater
UNIT SUPPLIED P006 - PuraceptorTM Class 1 with 20,000 litre retention tank
T.F.R. 6 LPS
OPERATION Due to the remote position of this transformer and the impact on the
environment in the event of a failure, it was essential to the power
provider to have a proven and reliable system. SPEL PURACEPTORTM
was selected due to its proven “track record” in supplying the power
industry, overall reliability and the necessity to have optimum quality
discharge. Whilst the design of 6 LPS from the bund area caters for
the nominal flow, a 20,000L spill retention was built into the system
to hold the capacity of a transformer rupture.
SITE Cranbourne Switchyard, VIC.
Cranbourne Switchyard APPLICATION Transformer Switchyard
RISK High
POLLUTANTS Transformer oil (70,000 litres)
DISCHARGE Stormwater to river
UNIT SUPPLIED P040 - PuraceptorTM Class 1 - oil capacity 70,000 litre
T.F.R. 40 LPS
OPERATION This unit was installed to treat stormwater and firewater from
the deluge system simultaneously. The unit caters for a 40 LPS
flow rate, and has the capacity to capture a 70,000L transformer
spillage and remain operational. SPEL units are designed and
built to BS EN 858.1. 2006 it was able to be used as a
designated flame trap, further enhancing its selection for this site.
SITE Fuel Service Station, NSW.
Fuel Station APPLICATION Stormwater runoff from forecourt and immediate
adjacent surfaces.
RISK High
POLLUTANTS Petrol, diesel, oils, suspended solids
DISCHARGE Stormwater drain to Georges River.
UNIT SUPPLIED P006 Puraceptor™ Class 1
T.F.R. 6 LPS
OPERATION Functions by gravity, will continue to be treated
in the event of a power failure. Equipped with an
oil/fuel alert probe for maintenance monitoring
and to alert in the event of an emergency spill.
Head Office
83 – 87 Fennell Street, Parramatta NSW 2150
02 9683 5555
www.spelproducts.com.au