                                                                                                                                                                                                                                      GENERAL CONSTRUCTION NOTES
                                                                                                                                                                                                                                      These Drawings shall be read in conjunction with all other
                                                       Colorbond "Trimdek" metal
                                                                                                                                                                                                                                      associated consultant's drawings and specifications, and with such
                 A                                     roof sheeting (or equivalent)
                                                       at 2.0° pitch.                                                                      B                           C                 D                                            other written instructions as may be issued during the course of
                                                                                                                                                                                                                                      the contract.
                                                       Rafters to structural details (shown                                                                                                                                           All discrepancies shall be addressed by the Supervising Officer/
                                                       indicatively).                                                                                                                                                                 Superintendent for decision before proceeding with the works.
                                                                                              600
                                                                                                                                                                                                                                      All dimensions shall be verified and confirmed on-site by the
                                                                                                                                                                                                                                      contractor before construction or fabrication is commenced.
                                                                                                                                                         2.0°                                                          Bed 1 Plate    The Contractor shall be responsible for maintaining the structure in
                                                                                                                                                                                                                            27950     a stable condition during construction and ensuring that no part
                                                                                                                                                                                                                                      may become overstressed.
                                                                                                                                                                                                                                      The proposed building work and materials shall comply with the
                                                                                                                                                                                                                                      Building Act 1975 and all relevant subordinate legislation; and
                                                                                                                                                                                                                                      relevant aspects of the NCC Volume 1 & 2 and with relevant SAA




                                                                                                     2500 max pitching
                                                                                                                                                                                                                                      codes as applicable for the class of building; QDC; Local
                                                                                                                                                                                                                                      Government Planning Schemes & Decision Notice.




                                                                                                                                                                                                              2700
                                                                                                                                                   870 csd
                                                                                                                                                                                                                                      RESIDENCE :
                                                                                                                                                                                                                                      All construction, workmanship and materials are to be in
                                                       Timber studwork with                                                                                                                                                           accordance with the current Building Code of Australia for Class
                                                       selected cladding.                                                  Guest                                                      WC                                              1a building
                                                                                                                                                                                                                                      GARAGE, CARPORT & SHED :
                                                                                                                                                                                                                                      All construction, workmanship and materials are to be in
                                                                                                                                                                                                                       Bed 1 Floor    accordance with the current Building Code of Australia for Class




                                                                                                                                                                                                              300
                                                                                                                         New timber framed floor                                                                            25250     10a buildings.
                                                                                                                                                                                                                                      All dimensions are in millimeters unless noted otherwise.
                                                                                                     Plasterboard lined                                                                                              Beds 2/3 Plate   Written dimensions to have preference over scaled dimensions.
                                                                                                     walls and ceilings.                                                                                                              All Cladding materials and elements shall be fixed in accordance
                                                                                                                                                                                                                             24950
                                                                                                                                                                                                                                      with the manufacturers specifications for the appropriate internal,
                                                                                                                                                                                                                                      wet area or external exposure and loading conditions and the
                                                                                                                         Floor framing to engineers details
                                                                                                                         (shown indicatively).                                                                                        supporting structure shown on these drawings.




                                                                                                                                                                           Linen
                     Timber sleeper retaining                                                                                                                                                                                         SAFETY




                                                                                                                                                                                                              3000
                     wall to builders specification.
                                                                                                                                Managers Office                                                                                       Before entering the construction site all persons doing so shall read
                                                                                                                                                                                                                                      & abide by the Code of Practice:Managing Risks in Construction
                                                                                                                                                                                                                                      Work - Work Health and Safety Act 2011
                     Existing rock faced
                     blockwork wall.
                                                                                                                                                                                                                                      Any work performed where existing compressed sheeting is
                                                                                                                                                                                       Ldry                                           present, shall have the material identified as Asbestos-free.
                                                                                                                                                                                                                                      Otherwise a licenced Asbestos compnay shall be engaged to
                                                                                                                                                                                                                                      perform the demolition & approve the site as safe prior to
                                                                                                                                                                                                                     Beds 2/3 Floor
                                                                                                                                                                                                                                      commencement of construction.
                                                                                                                                                                                                                             21950
                                                                                                                                                                                   Existing slab on ground.                           DRAINAGE
                                                               New stairs
                                                               to exist deck.
        FSL                                                                                                                                                                                       NSL                                 Floors to all wet areas to fall to a floor waste. Wet areas to be
                                                                                                                                                                                                                                      waterproofed to NCC 10.2.
                                                                                                                          Slab & footings to structural details
                                                                                                                          (shown indicatively).                                                                                       Sewerage to discharge to existing sewer in accordance with A.S. 3500.
                            Existing deck on slab.             New deck landing                                                                                                                                                       Surface drainage to discharge evenly within the site and without
                            (no change)                        to builders specification.                                                                                                                                             nuisance to adjoining properties.
                                                                                                                                                                                                                                      TERMITES
                                                                                                                                                                                                                                      Protection against subterranean termites to be in accordance
                                                                                                                                                                                                                                      with AS 3660 Part 1. (protection of buildings from subterranean
                                                                                                                                                                                                                                      termites.) Protection against subterranean termites to apply to all
                                                                                            Section 3                                                                                                                                 "primary building elements". The builder is to provide physical
                                                                                                                                                                                                                                      barriers to the entry by subterranean termites by construction of
                                                                                            1 : 50
                                                                                                                                                                                                                                      all slabs in accordance with AS 2870 (Residential Slabs and
                                                                                                                                                                                                                                      Footings.) and AS 3600 (Concrete structures code.) In addition
                                                                                                                                                                                                                                      all slab penetrations are to be protected using stainless steel
FENCING & RETAINING WALL (if indicated on site plan)                                                                                                                                                                                  mesh. (Termimesh or equivalent fitted to manuf. spec.)Regular
Height of fence (if required) including the height of retaining wall is not to exceed 2.0m above                                                                                                                                      inspections of the building are to be carried out to ensure the
natural surface level.                                                                                                                       NOOSA COUNCIL                                                                            barrier has not been bridged by termites. Inspections are to be
1000 high timber retaining wall (if required) with 65 dia Ag pipe (to discharge to stormwater line or                                        APPROVED PLAN                                                                            carried out as per notices.
pit) and granular backfill behind & wholly contained within the site. (>1000 high to engineers detail)                                  132003.220763.1 12 MAR2024




                                                                                                                                                                                                                                      plans2go
Proposed Residence                                                                                                                                                                             PETER COOKE                                     concept to                                 Postal Address :
                                                                 Job No           2366                                                              Design        PC                                                                                                                        28 Kawanna St
                                                                                  09                                                                                                           BUILDING DESIGNER
Kerrie McCartney                                                 Sht. no                                                                                                                       QBSA Lic : 81626                                                                             Mudjimba 4564
                                                                 Date             27-11-23                                                         Rev    C                                                                                                                                Email Address :
2-512 David Low Way                                                                                                                                                                                                                                                             [email protected]
                                                                 Drawn            PC                                                                                                           Plans2go Pty Ltd
Castaways Beach                                                                                                                                    Status Finishes                             0428 842316                               building application                   www.plans2go.blogspot.com

Used in these records

About this file

File size
3.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plan - 132003.220763.1.pdf · 3.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.