Skip to the record
Noosa's #1 Council Tracker.

Council archive · source document

Approved Plan OPW16-0229 · OPW16/0229

of 7

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
          -

   NOOSA COUNCIL
   APPROVED PLAN
OPW16/0229 16 DEC 2016


[OCR of page images]
 

1.

2.

 

 

 

 

 

 

 

 

 

 

 

 

--RL.7.300

REFER BIO-RETENTION
NOTES FOR
ADDITIONAL DETAILS.

   
 

 

 

 

 

 

 

 

-
a! REMOVABLE BOLLARDS
el
REFER TO DETAIL oN
DRIVEWAY CARPARK 1
CONCRETE V-DRAIN. REFER BUILDING aL780
DETAIL ON DRG C04. | FFL.8.300 es
“wef WHEEL STOP
SA + SEE = TS — Sn I
E | ,
ET1 EXISTING SURFACE — 100mm SUB-BASE MATERIAL CBR45 ry Y
PROVIDE IMPERVIOUS LINING ———]
SUBGRADE TO BE PROOF ROLLED BY REFER TO DETAIL A’ Hess

DATUM RL.6.000

CONSULTING ENGINEER & PRIOR TO
PLACEMENT OF SUB-BASE MATERIAL.

REFER TO RETAINING WALL RW1 DETAIL — |

— 1

 

 

 

 

 

 

 

 

   
   

RP.BDY

 

MAX.

[- ORIFACE INSIDE WALL OF PIT TO ENGINEERS DETAILS.
> 150mm EXTENDED DETENTION DEPTH

400mm SANDY LOAM

150mm SAND
y- 150mm DRAINAGE GRAVEL

[- PROVIDE IMPERVIOUS LINER

RL.7.600 DISCHARGE
CONTROL PIT.
I — 150mm ONSITE DETENTION DEPTH 10m?
1:2 BATTER

 

BIO-RETENTION

 

 

NOOSA COUNCIL
APPROVED PLAN
OPW16/0229 16 DEC 2016

 

 

WHEEL STOP ~~

 

 

0.S.D. OVERFLOW
rRL.7.450

 

 

 

 

 

REFER TO CONCRETE RETAINING ——|_
WALL CRW DETAIL

 

 

 

DATUM RL.6.000

 

RP.BDY

oe fa ™ 1:2 BATTER

SCALE 1:50

 

 

 

 

SECTION “AY
NOY,

 

 

 

 

 

FIX FILTER CLOTH TO FACE
OF WALL 300mm WIDE WITH

 

 

MIN.100mm COVER (SIMILAR Ht

 

SECTION (B
SCALE 150  \ C02

TO IPWEAQ STD. DRGS.)

 

 

DETAIL “A
SCALE 150 \-_/

 

 

 

 

BIO-RETENTION NOTES

NOTE:-

CONSTRUCTION, ESTABLISHMENT AND MAINTENANCE
OF THE BASIN TO BE CARRIED OUT IN ACCORDANCE
WITH SECTION 5.5 OF THE WSUD TDG

CONSTRUCTION MONITORING IN ACCORDANCE WITH HEALTHY
WATERWAYS BIORETENTION BASIN CONSTRUCTION AND

ESTABLISHMENT SIGN OFF FORMS (INCL PRE-START
AND FORMS A-G THROUGHOUT CONSTRUCTION )

NOTE:-FILTER BED DETAILS

MINIMUM FILTER DEPTH IS TO BE 0.90m min AND IS
to CONSIST OF THE FOLLOWING MEDIA

1. 0.40m OF SANDY LOAM MATERIAL WITH A
HYDRAULIC CONDUCTIVITY OF 180mm/h
AND PARTICLE SIZE OF 0.45mm

2. 0.15m DEPTH COURSE SAND
PARTICLE SIZE TYPICALLY 1mm

3. 0.15m (min) DEPTH GRAVEL DRAINAGE.
PATICLE SIZE 5-10mm SCREENINGS

4, uPVC (SLOTTED) PIPE AT 1.50m SPACING
TO BE INCLUDED IN FREE DRAINING AREA TO
ASSIST IN DRYING OUT THE DEVICE. THIS PIPE IS
TO CONNECT TO STORMWATER DRAINAGE.

NOTE:- STAGE CONSTRUCTION

FUNCTIONAL INSTALLATION
(TO BE COMPLETED DURING SUBDIVISION CONSTRUCTION

1, BULKING OUT AND TRIMMING

2. INSTALLATION OF OUTLET STRUCTURE

. INSTALLATION OF DRAINAGE LAYER (INCL SLOTTED PIPES)

. PLACEMENT OF TRANSITION LAYER AND FILTER MEDIA

. PLACEMENT OF TEMPORARY PROTECTION LAYER

. PLACE SILT FENCES AROUND THE BOUNDARY OF BASIN
TO EXCLUDE SILT AND RESTRICT ACCESS

nu ew

SEDIMENT AND EROSION CONTROL

(DURING BUILDING CONSTRUCTION)

THE BASIN IS TO BE MAINTAINED AS A SEDIMENT
AND EROSION CONTROL DEVICE.

OPERATIONAL ESTABLISHMENT

(AT THE COMPLETION OF BUILDING PHASE)

THE TEMPORARY LAYER ARE TO BE REMOVED TOGETHER
WITH ACCUMULATED SEDIMENT AND THE BASIN PLANTED
WITH THE PROPOSED LANDSCAPE DESIGN.

 

 

HEIGHT VARIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POST AS SPECIFIED OR TO MATCH
BOLLARD TYPE SPECIFIED FOR
PARK. HEIGHT AS SPECIFIED.
OPTIONS INCLUDE :

x 100x100 HARDWOOD POST

x 102x102 SHS POST

x 100x100 RECYCLED

PLASTIC POST.

REFER HINGE DETAIL
FOR FIXINGS

CONCRETE PATH AS
SPECIFIED OR 900x500x250
N25 CONCRETE FOOTING

REMOVABLE BOLLARD - SECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONSTRUCT JOINTS AT 8m CRTS.
3-R12 GAL DOWELS HORIZ. 300 LONG.
PROVIDE SQUARE CAP ONE END.
10mm COMPRESSIBLE FILLER FULL

POLYETHYLENE SEALANT TO 3 SIDES.

SCALE 1:10
0.20m
FORMED CONCRETE N32 [Wo 20 RADIUS
( J \
E

: SP
— 5
Pa =
Ee
—
o
x
4b ¢ =

N12-300 STARTERS 200 COG
S0COVER __
N12-200 HORIZ. 600 LA2 ——____|
3-L11 TM TOP & BTM, ——}-— —|— —
1 |, HEIGHT AND PROVIDE 10x10
< Ee
R10-600 LIGS 50 COVER ——t= §
a A co
|.
o Le

 

 

 

 

0.30m |

CONCRETE RETAINING WALL - CRW

 

1:20

225 OUTLET PIPE

 

 

 

 

 

 

 

 

 

 

 

10mm GALV. M/S FABRICATED HASP WITH
15mm CUT-OUT FOR PAD EYE. WELD

MASONRY ANCHORS FIXED TO HWD POST.

 

 

 

 

 

 

 

OR BOLLARD CAN FOLD DOWN.

 

 

 

 

 

 

 

 

 

 

IL.6.400
—— 10mm GALV M/S FABRICATED HINGE
FIXED THROUGH POST TO PAD EYE
WITH 4xM12 H/H GALV. BOLTS.
Ee
& 4 10mm M/S PLATE PAD EYE
FIXED TO SHS POST. 4xM12 C/S
E
oc
2
E Y HINGE MECHANISM SO PLATE
©
BN 2 4
4 . a 4xM12 C/S MASONRY ANCHORS
» » 6 OR APPROVED EQUIVALENT.
A 6 R > 4
yt > Ld > LJ A

REMOVABLE BOLLARD - HINGE DETAIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCALE 1:5
190 Ht BLOCKS
CONCRETE FILLED
NOTE WN 150 THick clay PLUG.
PROVIDE CONTROL Pa
JOINTS at 6.0m |
ENTRES MAXIMUM Ly
CENTRES MAXIM NN) -—+— nt6-400 HORIZ,, LAP 500
HEIGHT | BASE N ID
H B v8 —1— 300 FREE DRAINING
1000 800 lhl BACKFILL.
41200 1000 N N16-400 VERTICAL
1400 1200 NIN
1600 1400 ! 55 CLEAR COVER, STARTERS & VERT.
1800 1600 NIN
Na] N-——— wrwto arch spec.
Ya) | ~ 100 dia. AGG DRAIN IN 300 OF
CLEANOUT BLOCKS | = NOMINAL 10mm BLUE METAL
Po of CONNECTED TO STORMWATER
iO. DRAINAGE.
© . 7 +. . + NO
= | &
3 3.L11TM
‘NU N16-400 L12-300
“* I STARTERS L_ \16-400
399 | COG 300.
B

 

 

 

RETAINING WALL - RW1

1:20

 

IN ASSOCIATION WITH

 

 

 

 

 

 

 

11/16

SECTION ‘A’ AMENDED, RETAINING WALL DETAIL DELETED OP.G.

 

JAW.

 

 

 

09/16

ORIGINAL ISSUE DP.G.

J.A.W.

 

 

 

\ No.

DATE

 

 

 

ISSUE REVISED

 

CHECKED

 

0 1 2
ee
PRELIMINARY SALE A mT
NOT FOR CONSTRUCTION SCALE Bo aaa) 1: 20
DATUM 277? SCALES SHOWN ARE AT A1 SIZE

K

 

COZENSE
RCGANE

CONSULTING ENGINEERS ¢ CIVIL * STRUCTURAL

SUITE 7 ADVANCE BUSINESS CENTRE
39 LAWRENCE DRIVE NERANG

PO BOX 2711 NERANG QLD 4211

P: (07) 5578 4100

F: (07) 5578 4092

E: [email protected]
W: www.cozreg.com.au

PTY
LTD

CONSULT AUSTRALIA

Member Fitrn

DESIGNED JAW.

CLIENT

 

DRAWN DP.G.

D.S. & AS. DEVELOPMENTS PTY. LTD.

JOB NO.

 

 

CHECKED JAW.

PROJECT

 

APPROVED FOR AND ON BEHALF OF
COZENS REGAN GROUP PTY LTD
(RPECQ No 4)

(NPER No 540920)

({RPEQ No 4536)

 

 

PROPOSED FACTORY

AT LOT 12, 40 GATEWAY DRIVE, NOOSAVILLE
SECTION AND DETAILS

16441

 

 

= C05

ISSUE

 

 

 

 

 

 

 

 

 

 

 

Used in these records

About this file

File size
2.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plan OPW16-0229.pdf · 2.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.