                                               Cardno
 Project Title:  Noosa Civic
     Subject:    Rational Method Hydrology Calculations - Catchment A       Job No.:            J13041
    Designer: Benjamin C      Check:                 Date: 22/8/2014          Page:               1              1
Rain Fall Data Used:
                         Location:   NOOSA, BOM
                         AR&R Vol 2 1987 Parameters          Time (hrs)    i2 (mm/hr)   i50 (mm/hr)
                          Skewness       0.10                    1           51.60        96.00
                             F2          4.40                   12           10.20        24.50
                             F50        17.60                   72            3.40         8.90

Column and Variable Definition
             Variable                                        ARI (years)
                              1          2             5         10           20           50            100
                 fy          0.80       0.85          0.95      1.00         1.05         1.15           1.20

Catchment Data for Existing Catchment Conditions
              Variable      Value      Unit
                Area         9.09       ha
                  fi        0.153    Fraction
                 C10        0.731    Fraction

Catchment Discharges for Existing Catchment Conditions
            Adopted Time:               23    Minutes (or 0.38 hours)
              Variable                                    ARI (Years)
                             1          2          5            10            20           50             100
                  fy       0.80        0.85       0.95         1.00          1.05         1.15            1.20
              Intensity    66.9        85.5      107.3        119.9         137.1        159.7           177.0
             Discharge     0.99        1.34       1.88         2.21          2.66         3.39            3.92




                                                                           Calculation Type: QUDM Type 1 (A)
                                                                                          Version: EX.970907
                                                                                                    Part 1 of 1
Log in to download the original file

MCU14_0106 Appendix E - Engineering Report.pdf · 24.1 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.