Appendix B - Bushfire Management Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn6.3 Anticipated severity of bushfire attack For Site 1, the fuel values from Section 3 are applied along with the other inputs for calculating design fire parameters, summarised in Table 3 below. Fire Scenario West, north and east Fire Scenario SW, S, SE Fire Scenario Site 1 West Method 2 AS3959-2018 Method 2 AS3959-2018 Method 1 AS3959-2018 FDI 50 FDI 50 FDI 40 Forest @ 21/24.2t/ha. Forest @ 21/24.2t/ha. Forest Effective Slope under vegetation 0⁰ Effective Slope under vegetation 0⁰ Effective Slope under vegetation 0˚ Fire Intensity (Byram, 1959) Fire Intensity (Byram, 1959) 15 754kW/m (”MEDIUM”) 15 754kW/m (”MEDIUM”) Rate of Spread (Noble et al, 1980) Rate of Spread (Noble et al, 1980) 1.26kph 1.26kph Flame Height (modified Mc Arthur V Flame Height (modified Mc Arthur V equation, NSW RFS 2001) 11.09m equation, NSW RFS 2001) 11.09m Flame Width 100m Flame Width 20m Elevation of Receiver 2.4m Elevation of Receiver 2.4m BAL FZ within 10m of intact BAL FZ within 9m of intact BAL FZ within 10m of intact unmanaged vegetation unmanaged vegetation unmanaged vegetation BAL 40 from 10 - <13m BAL 40 from 9 - <12m BAL 40 from 10 - <13m BAL 29 from 13 - <19m BAL 29 from 12 - <15m BAL 29 from 13 - <20m BAL 19 from 19 - <27m BAL 19 from 15 - <19m BAL 19 from 20 - <28m BAL 12.5 from 27 – 100m BAL 12.5 from 19 – 100m BAL 12.5 from 28 – 100m Table 3. Calculated values for potential bushfire characteristics for Site 1 and methods used. Projected fireline intensity from the west is approximately 15 754 KW/m, equating to “MEDIUM” rather than “HIGH” as indicated under latest Council and State bushfire hazard mapping. The assessment validates classification of the area as BPA with required compliance against AS3959-2018. Whilst Method 2 indicates lesser setybacks to be viable than Method 1, particularly to the SW, S and SE, precaution should be taken given the nature of the vegetation and isolation of the site. In this instance it is recommended that Method 1 be applied to building construction and associated setbacks. Note that these minimum setbacks are less than the permitted clearing distance for essential management purposes, of 1.5 times the tallest tree height. The clearing required to meet these minimum setbacks is necessary for the construction of a dwelling to be considered acceptable risk. Any Class 10a structure built within 6m of the dwelling shall be constructed in accordance with this Standard. The significance of the radiant heat flux levels discussed is shown below in Table 4. Report compiled by Bushfire Risk Reducers for The Planning Place, July 2021 Page 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.