    1                                         2                                          3                                                   4                                               5                                             6


                                                                                     ANTENNA SUPPORT POST
A                                                                                    GROUND BAR SITEPRO1
                                                                                                                      EQUIPMENT KEYED NOTES:                                                                                                                       A
                                                                                     #MG406U-K (MOUNTED          1    ANTENNA MAST
                                                                                     BELOW EQUIPMENT W/
                                                                                     INSULATORS & TOWER          2    LNB GROUND
                                                                                     STANDOFF BRACKET)           3    HPBUC (BOOM ARM)
                                                                                     DOUBLE STACK LUGS           4    TXCVR GROUND
                  1
                                                                                                                 5    ELECTRONICS ENCLOSURE GROUND
                   2
                                                                                                                 6    (2) STACKED SECTIONS OF
                   3                                                                         6                        UNISTRUT FOR CABLE PATHWAY
B                  4                                                                                                                                                                                                                                               B
                   5                                                                 TO SAN GROUND STAKE

        370mm ABOVE GRADE                                                            RECORD GROUND RESISTANCE
        INSTALLED ON EAST SIDE                                                       MEASUREMENT USING A CLAMP-ON
        OF MAST (TYPICALLY ABOVE                                                     GROUND RESISTANCE TESTER:
        UNISTRUT FOR STANDARD                                                        NOTIFY CLIENT PM IF RESISTANCE
        SITES)                                                                       IS ABOVE 10 OHMS


        GROUND BAR CONNECTION DIAGRAM - ANTENNA SUPPORT
        NOT TO SCALE
C                                                                                                                                                                                                                                                                  C

                                                                         B           C       C
                                                                                                                      EQUIPMENT KEYED NOTES:
                                                                                A
                                                                                                                 A    TO PROPOSED OAN CABINET
                                                                                                                 B    TO PROPOSED RECEPTACLE POWER PANEL
                                                                                                                 C    TO PLATFORM POSTS



D                                                                                                                                                                                                                                                                  D




                         H-FRAME GROUND BAR SITEPRO1
                         #MG406U-K (MOUNTED BELOW
                         EQUIPMENT WITH INSULATORS)



                         RECORD GROUND RESISTANCE
                                                                                                                                                                                                              COMPLIANCE BOX
                                                                                                                                                                                                            COMPLETED AS PER DESIGN
                         MEASUREMENT USING A CLAMP-ON                                                  CONNECTION TO TELSTRA EXCHANGE
E                                                                                                                                                                                                           ALTERATIONS IN RED                                     E
                         GROUND RESISTANCE TESTER:                                                     TOWER EARTH OPTION, ONLY IF                                                                          NAME (PRINT)
                         NOTIFY CLIENT PM IF RESISTANCE        TO SAN GROUND STAKE                     UNDERGROUND SAN EARTH TO                                                                             SIGNATURE                     DATE
                         IS ABOVE 10 OHMS                                                              EXCHANGE EARTH NOT PRACTICAL

                                                                                                              THIS SHEET TO BE READ IN CONJUNCTION WITH SHEET G4 & G4-1.
                                                                                                                                                                                                       FOR CONSTRUCTION
                                                          GROUND BAR CONNECTION                              ORDER DRAWN CHKD                    AMENDMENT                      EXAM APPD DATE ISS
                                                                                                            183929 JM     MF FOR CONSTRUCTION - SP30092467WO015DOWN - SATELLITE RC PG 17.06.22 0.1
                                                          DIAGRAM - H-FRAME                                                                                                                          SATELLITE ACCESS NODE SITE 183929
                                                          NOT TO SCALE
                                                                                                                                                                                                             POMONA EXCHANGE
F                                                                                                                                                                                                               BAR CONNECTIONS DIAGRAMS                           F
                                                                                                                                                                                                           25 RAILWAY PARADE, POMONA, QLD 4568
                                                                                                                                                                                                     DWG                                         SHT       G4-3
                                                                                                                     C Telstra Corporation Limited ABN 33 051 775 556 All rights reserved.           NO.       QC100259                          NO.   .
    1                                         2                                          3                                                   4                                               5                   Cad file: QC100259.dwg                           A3
Log in to download the original file

QC100259_Pomona Exchange_DD_Rev01-220630.pdf · 2.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.