Original source · versioned page text
Appendix C - Stormwater Management Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnDRAINS Modelling Results Project number: 20220213 Calculations: B. Parry Street Address: 14-16 Reserve Street Locality: Pomona, NSC Date: 19/09/2022 Pre / Post Comparison 3 3 3 A.E.P Qy Pre (m /s) Qy Post (m /s) Qchange (m /s) Qchange (%) 63.2% AEP 0.044 0.048 0.004 9% 50% AEP 0.051 0.054 0.003 6% 0.2 EY 0.080 0.091 0.011 14% 10% AEP 0.095 0.098 0.003 3% 5% AEP 0.112 0.111 -0.001 -1% 2% AEP 0.129 0.137 0.008 6% 1% AEP 0.150 0.154 0.004 3% Tank Node Assumptions3kL attenuation storage Pre / Post w/ OSD Comparison https://www.slimlinerainwatertanks.com.au/aquaslim-squared-colorbond-steel-slimline-water- 3 3 3 A.E.P Qy Pre (m /s) Qy Post (m /s) Qchange (m /s) Qchange (%) Length 2.25 63.2% AEP 0.044 0.044 0.000 0% Width 0.88 m 50% AEP 0.051 0.050 -0.001 -2% Total Area 1.98 m² 0.2 EY 0.080 0.076 -0.004 -5% Low flow orifice 50 mm 10% AEP 0.095 0.091 -0.004 -4% Overflow 150 mm 5% AEP 0.112 0.104 -0.008 -7% Tank Height 1.87 m 2% AEP 0.129 0.123 -0.006 -5% Overlow height 1.72 m 1% AEP 0.150 0.140 -0.010 -7%
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.