Log in to see the plans as drawn SITE DETAILS
2.1. Existing Site Description
The existing site, known in real property terms as Lot 2 SP 115871, is located at 14-16 Reserve Street, Pomona. The
existing site contains a commercial premises, existing car parking area and undeveloped site areas with total
allotment being 1,782.5m².
The site has frontage to Reserve Street of approximately 30m, which is largely the existing commercial premises. The
car parking area and undeveloped areas located at the rear of the site to the east are accessed by an existing access
driveway approximately 5.5m wide shared by the adjacent lot to the North.
2.2. Existing Drainage Patterns
The subject site is on gently sloping land with the car parking and undeveloped land in the eastern portion of the
site falling at between 3% to 5% towards the eastern boundary. The driveway access from the western boundary is
steeper, falling at approximately 10% grade from the boundary.
An existing stormwater inlet pit is located at the rear of the existing car parking area to which the surface flows drain
following the natural contours of the site. A 250mm diameter pipe carries the existing flows along the northern
boundary of the Pomona Bowls Club discharging to an kerb inlet pit within the Station Street road reserve.
The roof of the existing building is drained by downpipes, with design plans for the existing development indicating
the roof drainage is discharged to the existing stormwater inlet pit. A pipe outlet from an existing shed building
within the adjacent lot to the north discharges into the car park as overland flows. No other upstream drainage is
expected to be conveyed through the development.
A locality plan for the site is presented below in Figure 2.1 - Site Locality Plan (Noosa Council Intramaps, 2022).
Existing 250mm
SW pipe
Figure 2.1 - Site Locality Plan (Noosa Council Intramaps, 2022)
Project number 20220213
File 20220213 Reserve St SWMP.docx, 2022-09-19 Revision 1 Page 5 of 16
P +61 7 5211 1003 A 75 Noosa Drive, Noosa Heads,Qld 4567 E [email protected] recorconsulting.com