Council archive · source document
Appendix 4 - accoustic report · MCU19/0117
Attached to the e-mail MCU19/0117 - Response to Information Request - Visitor Accommodation Type 3 – Rural (Guest House and Private Lagoon).
Mark Bain Constructions Pty Ltd Environmental Noise Level Impact Assessment for Proposed Wave Lagoon, 500/90 Beach Road, Noosa North Shore Page 4 of 16 CRITERIA All noise level measurements were conducted in accordance with the following: general requirements of the Queensland environmental protection legislation; Environmental Protection (Noise) Policy 2019; Noise Measurement Manual, Queensland Government, Department of Environment and Heritage Protection, Version 4, August 2013; Australian Standard AS 1055-2018, Acoustics – Description and Measurement of Environmental Noise. NOISE LIMITS For all of the steady state and time varying noise sources the noise limits have been defined in accordance with the Acoustic Quality Objectives and the default noise standards of the Queensland environmental protection legislation. In accordance with the default noise standards there are no noise limits for blowers, but the noise limits for pumps (which, by definition includes spa blowers) are: daytime (0700 to 1900 hours): background + 5 dB(A); evening (1900 to 2200 hours): background + 3 dB(A); night-time (2200 to 0700 hours): inaudible. It has been assumed that the above noise limit criteria would be equally applicable to blowers as well as pumps. The acoustic quality objectives are: Acoustic quality objectives, daytime and evening, external to dwelling: o 50 dB(A) LAeq,adj,1H; o 55 dB(A) LA10,adj,1H; and o 65 dB(A) LA1,adj,1H; Acoustic quality objectives, daytime and evening, inside dwelling: o 35 dB(A) LAeq,adj,1H; o 40 dB(A) LA10,adj,1H; and o 45 dB(A) LA1,adj,1H; Acoustic quality objectives, night-time, inside dwelling: o 30 dB(A) LAeq,adj,1H; o 35 dB(A) LA10,adj,1H; and o 40 dB(A) LA1,adj,1H; For the night-time period the internal noise criteria needs to be converted to be equivalent to outside the closest residences. Allowing a 5 dB(A) noise level reduction from outside to inside (based on all of the windows fully open and in accordance with the Queensland Environmental Protection Agency Ecoaccess Guideline Planning for Noise Control) the internal criteria would be equivalent to the following levels external to the dwelling: David Moore & Associates Pty Ltd Our reference: R19099/D3453/Rev.0/21.01.2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix 4 - accoustic report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.