NO WORKS DA
NOT FOR CONSTRUCTION
GENERAL NOTES:
(These notes apply to all drawings)
- These designs, drawings and specifications
are copyright and the property of Cayas
Architects and must not be used, reproduced
or copied wholly or in part without the
permission of Cayas Architects.
- Do not scale - use figured dimensions in
preference to scaled dimensions.
- All dimensions must be checked on site prior
to the commencement of construction and/or
manufacture of any item.
- Where demolition work is included, allow to
makegood all affected surfaces.
- Ensure that all conditions of the building
certification are complied with.
Where ambiguities or discrepencies exist,
Cayas Architects shall be contacted for
clarification or it will be deemed that the more
A B 17935
C D A90.00 A B C D expensive option has been allowed.
17935
4805 6635 6500 - All work is to comply with all relevant sections
2.
4805 6635 6500 of the NCC and/or Austalian Standards.
- These drawings are to be read in conjunction
with all other documentation, schedules &
G H consultant documentation.
A30.01 A30.01
The contractor is to allow for all neccessary
floor preperation works.
- Provide all warranties as per the
manufacturers & suppliers standard warranties.
- All materials, equipment, fixtures, fittings, etc.
shall be new first quality without exception.
1 1 Supply, delivery, storage, installation, etc. is to
be as per the manufacturers most recent
written recommendations.
- Supply & install fire extinguishes to comply
with Australian Standards to the are of the
proposed work.
- Termite Protection is to be provided to
comply with AS 3660.1-2000 and clarification to
6115
6115
be provided on completion.
- The construction and fit out of commercial
kitchens and bars is to comply with AS 4674-
2004.
Keynote Legend
2 2
Key Value Keynote Text
(ex) Existing
AP Access Panel
COL Column
6115
6115
(ex.)
COL COL
3 3
24465
24465
EXISTING MECHANICAL DUCTS EXISTING MECHANICAL DUCTS
OVER MEZZANINE OVER MEZZANINE
LIQUOR STORE LIQUOR STORE
6115
6115
UNDER UNDER
INSTALL NEW SAFETY RAIL TO
MATCH EXISTING
EXTEND MEZZANINE
FLOOR OVER LUNCHROOM
TO MATCH EXISTING
MEZZANINE FLOOR
COS
2470
4 4
4255
(ex) COS
AP AP
6115
6115
EXISTING ACCESS
ACCESS HATCH AND
HATCH AND LADDER TO
LADDER TO A/C DASHED LINE INDICATES
A/C PLATFORM
PLATFORM FLOOR EXTENSION ABOVE
NEW TEAM ROOM
5 5
G H
A30.01 A30.01
Existing Mezzanine Plan Proposed Mezzanine Plan 4 Minor Change MT 08.02.21
1 1 : 100 2 1 : 100 3
2
Amendments
Amendments
MT 08.09.20
MT 31.07.20
1 Construction Issue MT 22.07.20
issue revision initials date
Cayas
Suite 2, 19-25 Musk Avenue, Kelvin Grove. PO Box 360, Wilston Q 4051
p 07 3356 6100 e [email protected]
client ALH Group
project Villa Noosa Hotel - Dan
Murphy's
drawing title Existing and Proposed
Mezzanine
drawn MT
date 03/04/20
scale 1 : 100@A1
project no. drawing number issue
1905 A10.03 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.