Council archive · source document
Noise Report [As Published] · 132007.2398
RSL Care == Proposed RSL Retirement Village, Cooroy — Road and Rail Noise Assessment S= specified by the Queensland Environmental Protection Agency have been applied for the purposes of the assessment. Section 2.3.2 discusses these criteria in detail. 2.3.2 Queensland Environmental Protection Agency The Environmental Protection Agency, through amendments to the Environmental Protection Regulation, places noise nuisance limits on air conditioning equipment and refrigeration plant as detailed in Table 2.2. TABLE 2.2: NOISE LIMITS FOR FIXED PLANT . . Adjusted Maximum Sound Equipment Period Pressure Level (LA10) 7 am—10pm < 50 dB(A) Air-conditioning or refrigeration The higher of: equipment 10 pm - 7am Background noise level plus 5 dB(A) or 40 dB(A) For intermittent noise sources, such as noise from service and delivery vehicles (as shown on Figure 2), a commonly adopted criteria is an average Laio noise level not exceeding average background levels by more than 3 dB(A). This criteria is commonly applied by the Environmental Protection Agency as a licence condition for industrial premises. AIR NOISE ENVIRONMENT PTY LTD P:\1750\REPORTING\M750FINAL.DOC Page 5