Council archive · source document
Noise Report [As Published] · 132007.2398
— ASL Care == Proposed RSL Retirement Village, Cooroy — Road and Rail Noise Assessment facades requiring Construction Category 3, the required mitigation should be determined upon further analysis by a qualified noise consultant, in accordance with clause 3.4 of AS 3671. Given the required construction category, AS 3671 provides typical STC information for standard construction types. STC (Sound Transmission Class) is a commonly referenced descriptor of the effectiveness of a material to reduce the noise energy transmitted through that material. The TNR must be adjusted to give the STC, and is estimated as equivalent to TNR + 6 dB(A) to account for the spectral composition of the noise source (as per Table 4.5). Table 4.6 presents typical STC data for standard construction types that may be suitable for achieving the required noise reductions identified above (except for the first floor of Apartment 2). For construction materials associated with the first floor of Apartment 2, refer to Table 5.4 in Section 5.3.2 of the Rail Noise Assessment. TABLE 4.6: TYPICAL STC RANGES FOR STANDARD CONSTRUCTION TYPES sTc Component Range Examples of Construction Pitched roof with 0.6 mm corrugated galvanised iron or Ceiling / Roof 36 - 38 6mm corrugated cellulose-cement over two layers of gypsum plasterboard (AS 3671) Conventional timber stud-framed walls, clad externally with | 9 mm thick flat cellulose-cement sheets, and internally External Walls | 36-38 | with 10 mm thick plasterboard, cavity filled with mineral wool (AS 3671) . . 10 mm single glazing or double glazing (7mm laminated Windows 33-35 and 6 mm at 6 mm) (AS 3671) Before any construction material is chosen for the affected receptors, STC information should be sought from the suppliers to ensure that the minimum STC’s as detailed in Table 4.5 are achievable. In order to achieve design STC ratings it is essential that the acoustically treated areas be constructed in a manner conducive to maximising sound attenuation. For example there must be no air gaps around windows or at the eaves, which could act as noise pathways. As a minimum it is recommended that all building elements (including the roof) are selected to achieve the minimum STC as defined in Table 4.6. 4.6.5 Open Space In order to minimise noise levels at open spaces for ILUs it would be necessary to provide useable areas in the shadow zone of each of the ILU buildings. Additional shielding in the form of architectural acoustic barriers may also be required to increase the compliant area for some of the ILU buildings. AIR NOISE ENVIRONMENT PTY LTD P:\1750\REPORTING\1750F INAL.DOC Page 19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noise Report [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.