Council archive · source document
Noise Report [As Published] · 132007.2398
ASL Care == Proposed RSL Retirement Village, Cooroy — Road and Rail Noise Assessment SS 5 RAIL NOISE ASSESSMENT 5.1 NOISE PREDICTION METHODOLOGY The potential impact of rail noise on the proposed development has been determined using the baseline noise monitoring data set. Typically, noise contour data is provided by Queensland Rail (QR) identifying the setback distance required for achieving compliance with the Lamax 87 dB(A) criteria. Upon discussion with QR, it was determined that there was no existing noise contour data available for the relevant section of the Cooroy Railway Corridor, hence the need to rely on the monitoring data for this assessment. Section 5.2 discusses the monitoring results associated with train noise for the proposed retirement village site. 5.2 ASSESSMENT OF MONITORING RESULTS Based on the noise monitoring data presented in Table 3.3 (Section 3.4), the 24-hour Laeq Criterion of 65 dB(A) is expected to be achieved at the development site. Table 5.1 presents the Lamax noise levels measured by Air Noise Environment at the site boundary adjacent to the Cooroy Connection Road (see Figure 1). TABLE 5.1: MAXIMUM NOISE LEVELS AT THE DEVELOPMENT SITE BOUNDARY FRONTING THE COOROY CONNECTION ROAD (dB(A)) Source of Data Lamax (Free-Field) Continuous unattended monitoring 95.0 Attended noise monitoring of train noise 88.8 The attended noise measurements at the boundary of the site have determined that the Lamax noise level of a passing QRail tilt train is 88.8 dB(A). During the unattended noise monitoring, the highest Lawax noise measurements determined were 94.0 dB(A) and 95.0 dB(A). These noise levels may potentially be associated with train horns. Hence, an exceedance of up to 10.5 dB(A) relative to the EPP noise criteria is expected for the portion of the site nearest the rail line. The noise levels indicated in Table 5.1 were measured at the site boundary, at a distance of 40 m from the passing trains. Based on noise attenuation calculations, compliance with the 87 dB(A) criterion is predicted to be achieved at a setback distance of 75 m from the railway line. Therefore, 23 ILU buildings and Apartment 2 exceed the train noise criterion. Mitigation options are presented in the following sections. AIR NOISE ENVIRONMENT PTY LTD PA1750\REPORTING\1750FINAL.DOC Page 21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noise Report [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.