Council archive · source document
Noise Report [As Published] · 132007.2398
= RSL Care == Proposed RSL Retirement Village, Cooroy — Road and Rail Noise Assessment SS The design limit for any continuous fixed plant at the proposed aged care facility has been calculated on the basis of the following assumptions: » a 40 dB(A) noise limit (as specified in the EPP(Noise)), which the total noise level from all continuous noise sources must not exceed; * aminimum source to receptor distance of 25 m (for closest ILU); and + all plant are located in direct line of sight of the nearest neighbouring property (ie, they are not shielded by the roofline or other structures or topographic features). On the basis of these assumptions, the total sound power level from all continuous noise sources at the site must be a maximum of 76 dB(A) to ensure that the specified night-time criteria of 40 dB(A) is not exceeded at the nearest receptor position. If all noise sources are shielded from the nearest receptors a sound power level of 86 dB(A) or more may be acceptable depending on the height of the sources relative to the acoustic screening and the type of structure involved. It is recommended that continuously operating plant are located as far as possible from proposed potentially sensitive development. 6.2.2 Loading Dock Noise The proposed site layout has an area designated for service access associated with the aged care facility, as shown on Figure 2. The regular services associated with the aged care facility will most likely include refrigerated food trucks and waste disposal services. Based on site survey plans, the minimum distance to the nearest sensitive receptors is 50 m (one-storey residential house to the north of the development site). Given the short-term nature of the above noise sources, the appropriate criterion to use for assessing the acoustic impact is a background Laio plus 3 dB(A) noise level. Noise monitoring Position 2 indicates an Laio noise level for the period between 7 am to 6 pm to be 56.1 dB(A). Hence, a 59.1 dB(A) criterion is adopted. The 56.1 dB(A) noise level was measured during a weekday, when the majority of service vehicles are expected to make deliveries. Table 6.1 presents a summary of maximum source noise levels for refrigerated truck deliveries and waste disposal vehicles measured by Air Noise Environment personnel. Table 6.2 presents a summary of maximum predicted receptor noise levels for each of the sources identified in Table 6.1. TABLE 6.1: LOADING DOCK SOURCE NOISE LEVELS Noise Source Sound Pressure Level at 1 metre (dB(A)) Refrigerated Truck 91 Waste Collection Vehicle 93 AIR NOISE ENVIRONMENT PTY LTD P:\1750\REPORTING\1750FINAL.DOC Page 25
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noise Report [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.