Original source · versioned page text
Generally in Accordance OPW12-0095.01 Approved Plans.pdf
-
NOOSA COUNCIL
GENERALLY IN ACCORDANCE
OPW12/0095.01 3 APR 2018
·
·
·
RPEQ DESIGNED SHORING SYSTEM TO BE
OBTAINED PRIOR TO COMMENCEMENT OF
WORKS ON SITE.
CONTRACTOR TO ENSURE EXCAVATION
FACE ADJACENT TO BOUNDARY IS IN A
STABLE STATE AT ALL TIMES DURING
CONSTRUCTION.
CONTRACTOR TO ENSURE NO DAMAGE
OCCURS TO ADJOINING PROPERTY
DURING WORKS.
28/02/2018 N:\M1717\STAGE 5\DESIGN\WORKING DRAWINGS\EARTHWORKS
NORTH: SCALE: ISSUE: TITLE: DETAILS:
PROJECT: PLAN: ISSUE:
1:20 THIS SCALE SHOWN IS ORIGINAL DRAWING SCALE
BRISBANE - SUNSHINE COAST - CENTRAL QLD PLANNERS 0 0.2 0.4 0.6 0.8 1 (A1) 1:20 2 EARTHWORKS DETAILS PLAN M1717E5 EW02 A
SUNSHINE COAST URBAN DESIGNERS A1 (A3) 1:40
Metres
LOCAL AUTHORITY REF:
237-239 Bradman Avenue, SURVEYORS DO NOT SCALE FROM THIS DRAWING - USE ONLY DIMENSIONS PROVIDED - IF IN DOUBT PLEASE ENQUIRE
NOOSA COUNCIL
Maroochydore Qld 4558 DESIGNED PGM
NOOSA DOMAIN PTY. LTD. COUNCIL REF:
ENGINEERS APPROVED T.MCKINNEY A.FRASER J.PAPPAS
P 07 5450 3900 W www.jfp.com.au
C O N S U L T A N T S JFP URBAN CONSULTANTS PTY. LTD. A.C.N. 050 414 045 LANDSCAPE ARCHITECTS __________________________________
RPEQ 5087
S.MARSH
RPEQ 5691 RPEQ 6086 DRAWN
CHECKED
PGM
ADF A ORIGINAL ISSUE FOR COUNCIL 28/02/18 PGM
NOOSA DOMAIN RETIREMENT VILLAGE OPW12/0095
FOR AND ON BEHALF OF JFP URBAN CONSULTANTS PTY LTD
RPEQ 8068 DATUM: AHD ISSUE: DETAILS: DATE: INIT: 35 WALTER HAY DRIVE, NOOSAVILLE FILE NAME: EARTHWORKS.DWG
COPYRIGHT © 2011 JFP URBAN CONSULTANTS PTY LTD THIS DOCUMENT MAY NOT BE COPIED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS IN PART OR IN WHOLE WITHOUT THE WRITTEN CONSENT OF JFP URBAN CONSULTANTS PTY LTD.
[OCR of page images]
EARTHWORKS NOTES
1, SITE TO BE FREE DRAINING TO ROOFWATER DRAINAGE OR ROADWAY
CLEARING AND GRUBBING
2. ANY CLEARING REQUIRED TO BE UNDERTAKEN BY THE CONTRACTOR |S TO BE
STRICTLY IN ACCORDANCE WITH THE COUNCIL APPROVED VEGETATION MANAGEMENT
PLAN, INCLUDING THE LIMITS OF ALLOWABLE CLEARING, TREE PROTECTION
REQUIREMENTS AND THE USE OF A FAUNA SPOTTER/CATCHER, AS SPECIFIED.
3. UNLESS OTHERWISE SPECIFIED OR DIRECTED, THE AREA TO BE CLEARED IS THAT
REQUIRED BY SITE REGRADING WORKS, INCLUDING THE AREA OCCUPIED BY THE
COMPLETED ROAD FORMATION AND ASSOCIATED DRAINAGE WORKS AND EROSION AND
SEDIMENTATION MEASURES, THE CONTRACTOR SHALL ENSURE THAT ONLY THE
ABSOLUTE MINIMUM AREA FOR CONSTRUCTION IS CLEARED
4. THE AREA WITHIN THE LIMITS OF CLEARING SHALL BE CLEARED OF ALL VEGETATION,
BOTH LIVING AND DEAD, ALL MINOR MAN-MADE STRUCTURES (SUCH AS FENCES,
BUILDING MATERIAL AND EXISTING DRIVEWAYS), ALL RUBBISH AND OTHER MATERIALS
WHICH, IN THE OPINION OF THE SUPERINTENDENT, ARE UNSUITABLE FOR USE IN THE
WORKS WITH THE EXCEPTION OF CERTAIN TREES MARKED FOR PRESERVATION.
5. ALL TREES AND STUMPS ON OR WITHIN THE LIMITS OF CLEARING, THAT ARE TO BE
REMOVED BY GRUBBING OPERATION SHALL BE CARRIED OUT TO A DEPTH OF 0.5m
BELOW THE NATURAL SURFACE OR 1.5 METRES BELOW THE FINISHED SURFACE LEVEL,
WHICHEVER IS THE LOWER,
TOPSOIL
6. ALL TOPSOIL ON ROADWORKS AREAS SHALL BE STRIPPED AND STOCKPILED PRIOR TO
THE COMMENCEMENT OF ANY EARTHWORKS OPERATIONS. A TOPSOIL DEPTH OF 150mm
HAS BEEN USED TO DETERMINE TOPSOIL AND EARTHWORK QUANTITIES. THE
CONTRACTOR IS TO SATISFY HIMSELF OF THE ACCURACY OF THESE QUANTITIES AND
TO MAKE ANY NECESSARY ALLOWANCE IF HE DISAGREES WITH QUANTITIES
EARTHWORKS
7, EARTHWORKS ARE TO BE IN ACCORDANCE WITH AS 3798 “GUIDELINES ON
EARTHWORKS FOR COMMERCIAL AND RESIDENTIAL DEVELOPMENTS”
{LATEST ISSUE - INCLUDING ALL AMENDMENTS).
8. ALL FILLING SHALL BE COMPLETED TO A LEVEL 1 ARRANGEMENT, UNDER THE
SUPERVISION OF THE PRINCIPAL'S APPOINTED GEOTECHNICAL ENGINEER.
9. THE EARTHWORKS QUANTITIES FOR ROADWORKS ARE CALCULATED USING THE
MINIMUM ALLOWABLE TOTAL PAVEMENT THICKNESS (NOMINAL PAVEMENT).
VARIATIONS TO THE PAVEMENT DEPTHS WILL BE PAYABLE AT THE RATES SHOWN IN
THE PRICED SCHEDULE OF RATES.
10, “CUT” AND "FILL" QUANTITIES HAVE BEEN CALCULATED TO THE UNDERSIDE OF THE
TOPSOIL LAYER
11, ALL EARTHWORK QUANTITIES HAVE BEEN CALCULATED AND BILLED IN THE CONTRACT
AS "NETT" QUANTITIES, THAT IS NO ALLOWANCE FOR BULKING OR COMPACTION HAS
BEEN MADE.
12, ALL FILL PLACED ON THIS SITE IS TO COMPRISE OF ONLY NATURAL EARTH AND ROCK
AND IS TO BE FREE OF ALL CONTAMINANTS (REFER TO THE ENVIRONMENTAL
PROTECTION ACT 1994 SECTION 11.), NO DEMOLITION MATERIAL IS TO BE USED.
SITE FILLING COMPACTION/TES TING
13. MATERIAL TO BE PLACED IN 300mm(MAXIMUM) LAYERS AND COMPACTED TO A MINIMUM
OF 95% AS. 1289(STANDARD) OF THE MAXIMUM DRY DENSITY. THE INSITU DENSITY OF
THE FILL MATERIAL SHALL BE TESTED AT THE RATE OF ONE LOCATION PER
ALLOTMENT AT THE FOLLOWING INTERVALS
© TOTAL DEPTH LESS THAN 300mm: -NO TEST REQUIRED
© = TOTAL DEPTH OF FILL 300mm - 600mm: -ONE(1) TEST PER ALLOTMENT
© TOTAL DEPTH EXCEEDING 600mm: -ONE(1) TEST IN THE FIRST LAYER THEN
-ONE(1) TEST ON EACH ALTERNATIVE LAYER
PLACED OVER THE FIRST LAYER
RETAINING WALL CERTIFICATION
1, CIVIL CONTRACTOR TO OBTAIN DESIGN AND CONSTRUCTION
RPEQ CERTIFICATION FOR ALL CONCRETE SLEEPER, SANDSTONE
BOULDER & CONCRETE BLOCK RETAINING WALLS.
2. WALL DESIGN AND CERTIFICATION TO BE PROVIDED TO
SUPERVISING ENGINEER PRIOR TO CONSTRUCTION,
3. CONSTRUCTION CERTIFICATION TO BE PROVIDED TO SUPERVISING
ENGINEER PRIOR TO “ON MAINTENANCE" INSPECTION
SAFETY FENCE NOTE
STAR PICKET AND SAFETY BARRIER MESH FENCE TO BE ERECTED
ON TOP OF ALL RETAINING WALLS GREATER THAN 1.0m IN HEIGHT
80mm THICK FIBRECRETE CONCRETE
SPOON DRAIN WHERE SITE FALLS
TOWARD WALL (300 MIN WIDTH)
FENCE POST BRACKETS SHALL BE
ATTACHED TO UB POSTS FOR FUTURE
1.2m HIGH POOL FENCE IF ORDERED
SETOUT POINT
400mm MIN
CENTRE OF EXISTING
UB POST } SURF ACE
‘
x| EL ~ |" — cOMPACTED CLAY
s| 3 at MATERIAL 150mm THICK
€ . BACK OF STEEL
a U 4 UB POST
- — GEOTEXTILE FABRIC
STEEL UB POST
AT 2.0m CENTRES
|
IH
FINISHED
lal
IH
CONCRETE SLEEPER
SURF ACE “ PANELS
| — eree panne
& | 6! GRANULAR FILL
VA 7A _— 9100 SLOTTED DRAINAGE PIPE
LL TO DISCHARGE 70 DRAINAGE
POST FOOTING TO BE Le |: SYSTEM AS ADVISED ON SITE
LOCATED ENTIRELY IN |
PRIVATE PROPERTY a.
CENTRE OF ——+|
450mm FOOTING
TYPICAL SECTION - TYPE ‘A’
1.5m MAX CONCRETE SLEEPER/UB POST RETAINING WALL
SCALE 1:20
NOTE: RETAINING WALL DESIGN AND CONSTRUCTION
CERTIFICATION TO INCORPORATE LOADING FROM
FUTURE 1.2m HIGH POOL FENCE
EXISTING SERVICES LOCATIONS
THE DESIGN DETAILED ON THIS PLAN HAS BEEN PREPARED BASED
NOTE:
THE CONTRACTOR IS TO ENSURE THAT FOOTINGS FOR
RETAINING WALLS ARE CLEAR OF THE PROPOSED SEWER
AND ROOFWATER LINES.
PRIOR TO COMMENCEMENT OF WORKS
REFER TO VEGETATION MANAGEMENT
PLAN, REHABILITATION PLAN AND
LANDSCAPE ARCHITECTS PLANS
ON SERVICE AUTHORITY AS CONSTRUCTED INFORMATION.
NO POT HOLING HAS BEEN UNDERTAKEN TO VERIFY EXISTING
SERVICES LOCATIONS AND DEPTHS.
IT IS THE CONTRACTORS RESPONSIBILITY TO UNDERTAKE POT HOLING
(HYDROVAC EXCAVATION) PRIOR TO COMMENCEMENT OF CONSTRUCTION.
NOOSA COUNCIL
GENERALLY IN ACCORDANCE
OPW12/0095.01 3 APR 2018
RPEQ DESIGNED SHORING SYSTEM TO BE
OBTAINED PRIOR TO COMMENCEMENT OF
WORKS ON SITE.
CONTRACTOR TO ENSURE EXCAVATION
FACE ADJACENT TO BOUNDARY IS IN A
STABLE STATE AT ALL TIMES DURING
CONSTRUCTION.
CONTRACTOR TO ENSURE NO DAMAGE
OCCURS TO ADJOINING PROPERTY
DURING WORKS.
5) DIAL BEFORE |
ey YOU DIG
www.1100,com.au
The Essential First Step
Pansy
ae EARTHWORKS DETAILS PLAN M1717E5 EWO2
(A3) 1:40) “ee LOCAL AUTHORITY REF:
NOOSA COUNCIL
0 NOT SCALE FROM THIS DRAWING - USE ONLY DIMENSIONS PROVIDED -IF IN DOUBT PLEASE ENQUIRE
NOOSA DOMAIN PTY. LTD.
= JFOP
atin eS, Ree tS. Tema
URBANCONSULTANTS _ eos GicieoTADF]_A_| ORIGINAL ISSUE FOR COUNCIL 28/02/18 | pam | NOOSA DOMAIN RETIREMENT VILLAGE OPW12/0095
Tmocaromumncomamcovae OSMARK SUM hab | ub oeras owe Ter} 35 WALTER HAY DRIVE, NOOSAVILLE FLENAME: — EARTHWORKS.OWG
TTRTOR] BOTS Ne WATTATAST AGE S\DESTGN WORKING DRAWINGS ERRTHTORRS
“COMA
© DOLL? URBAN CONSULTANTS PTV UTD TSO TT MAYNOT
ED OR TRANS
SV ANY MEANS IN PART ORINW
ITHOUT THE WRITTEN CONSENT OF IFP URBAN CONSULTANTS PTY LTD,
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Generally in Accordance OPW12-0095.01 Approved Plans.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.