Log in to see the plans as drawn GENERAL NOTES:
ROOF OVER VERANDAH BY OTHERS
NEW ROOF BY 1. This structure has been designed in accordance with the
OTHERS PRIVACY SCREEN BETWEEN POSTS
TO SCREEN TO NEIGHBOURING UNIT
current editions of the Building Code of Australia (NCC-2022)
TO COUNCIL REQUIREMENTS and the Queensland Building Act - Standard Building Law,
2. All building work shall comply with the current editions of
the relevant Australian and New Zealand Standards and other
documents as called up in the NCC-2022.
GFL CH GFL CH
3. Unless stated otherwise, all materials shall be as listed in
2700 2700 the Accredited Building Products Register.
GFL GFL 4. The builder shall check and verify all dimensions, fixings,
fittings and finishes before commencement of works.
0 0
5. Reduced levels (RL's) and ground contours as shown have
POOL FENCING not been measured by the author of these documents and may
AROUND SPA GARDEN SHED
only indicate the approximate general shape of the terrain and
NORTH ELEVATION SOUTH ELEVATION heights of the various building elements. Unless stated other-
wise, actual accurate levels shall be determined either by the
SCALE 1:100(A3) SCALE 1:100(A3) builder or a land surveyor prior to commencement.
6. Written dimensions as show on the drawings take pre-
cedence. DO NOT SCALE DIRECT FROM THE DRAWINGS!. In the
event that questions arise, discrepancies or errors are
noticed, please do not proceed with the work without
requesting further instructions from the builder and/or the
building designer.
7. Construction must not vary from these drawings without
the written approval of the owner/s, licensed certifier and
the building designer.
8, Unless stated otherwise, these drawings have been prep-
ared either for client approval, planning approval or building
permit approval only. No responsibilty will be accepted by
the building designer for drawings or further construction (shop)
drawings prepared by others.
ROOF AND STRUCTURE BY OTHERS
9. Any anchor rods/bolts and roof truss tie-down details
shown are for standard trusses only. The builder shall obtain
-
tie-down details for any non-standard trusses such as hips,
APPROVED PLAN GFL CH girders, valleys etc. from the truss manufacturer or struct-
ural engineer. This information shall be made available to
51995.1534.03 2700 the Local Government or Licensed Certifier at the time of
NOOSA COUNCIL GFL
NEW DECK OVER EXISTING SLAB
TO ENGINEERS DESIGN lodgement of the Building Permit Application.
19 DECEMBER 2022
0 200 SERIES BLOCK WALL 60/60/60 FRW 10. Refer to the structural and/or geochemical engineering
ON BOUNDARY FINISHED ABOVE TOP OF
DECK FLOOR LEVEL
report/s for footings and slab details not shown.
RECESSED SPA WITH NATURAL GROUND BATTERED
DECK EDGE AND PRIVACY SCREEN AND LANDSCAPED 11. Unless stated otherwise, rainwater discharge either shall
be directed to the road kerb or dispersed within the prop-
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS EAST ELEVATION erty boundaries to Local Government requirements.
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. SCALE 1:100(A3)
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION DATE GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
THIS DRAWING IS SUBJECT TO COPYRIGHT AND MUST NOT BE REPRODUCED IN
A
C
ORIGINAL PRELIMINARY ISSUE
REVIEW CHANGES #2
21.06.22
07.07.22
(B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ELEVATIONS PROPOSED DECK & SPA WHOLE OR IN PART WITHOUR WRITTEN PERMISISON. c 2022. 222-079 F
Bli Bli Qld 4561 OWNER/S: SHEET No.:
D REVIEW CHANGES #3 DECK TO BDY 13.07.22 SCALE: DATE: SITE ADDRESS:
Mob 0438786080 UNIT 5 / 6 ADVANCE PLACE,
MR & MRS McINNES 4 OF -
E 4.85m LONG ROOF BY OTHERS 30.08.22 DESIGN DRAFTING
Gagman Pty Ltd Email -
1:100 (A3) JUNE.2022 SUNRISE BEACH, QLD
F 60/60/60 FRW 19.09.22 QBCC No 1261742 [email protected]
Document Set ID: 22167849
Version: 1, Version Date: 09/11/2022