Specific Outcomes Probable solutions Proposal
or
ii) for a building of 2 or more storeys
- 50% on the ground floor and 30% for
the upper storey(s), or 40% for all
storeys for a building of 2 or more
storeys;
c) for other classes with the Detached
Housing Zone, does not exceed—40%;
d) for the Semi-Attached Housing Zone
does not exceed 40%;
e) for the Attached Housing Zone does
not exceed 40%;
f) for the Visitor Mixed Use Zone does
not exceed 40%; or
g) for the Shire Business Centre Zone in
Precincts E1, E2, E6 and E7 does not
exceed 50%.
O12 For the Semi-Attached Housing Not applicable
Zone buildings do not exceed a plot
ratio of 0.45:1
O13 For the Attached Housing Zone the Not applicable
maximum gross floor area is equivalent
to the maximum allowable population in
persons multiplied by 40m2.
O14 For the Visitor Mixed Use Zone, the Not applicable
maximum gross floor area equals the
allowable population in persons
multiplied by 40m2, provided that the
gross floor area does not exceed
13,600m2.
O15 For the Business Centre Zone, Not applicable
outside of the Mary Street/Thomas
Street Precinct the maximum plot ratio
is —
a) 0.8:1 for site areas up to and
including 2,000m2; plus
b) 0.3:1 for the balance portion of the
site area in excess of 2000m2.
O16 Within the Shire Business Centre Alternative Outcome
Zone, the maximum plot ratio for Refer section 7.4.2 of planning report.
development within the following
precincts is —
a) Precincts B1 and B2 combined- 0.5:1;
b) Precinct B3- 0.8;
c) Precinct E1- 0.6;
d) Precinct E2- 0.6;
e) Precinct E3- 0.6;
f) Precinct E4- 0.6;
g) Precinct E5- 0.6
h) Precinct E6- 0.6;
i) Precinct E7- 0.6;
j) Precinct RES- 0.6; and
k) Precinct REC/MU- 0.1.
Flooding and drainage
O17 Buildings and other works are S17.1 For new buildings or structures Not applicable
designed and sited to— or additions more than 50m2 gross floor No minimum floor level applies to the
a) provide flood free access to premises area to an existing building or structure, site.
and flood free habitable areas; floor levels for habitable rooms are not
b) allow only minor, short term and less than the specified minimum floor
infrequent flooding of non-habitable levels
areas; AND
c) ensure drainage does not adversely S17.2 Where Council infrastructure is Complies
impact upon other premises; and available— any drainage (including All drainage will flow to Council
d) ensure filling or excavation does not buildings and yards) flows to that infrastructure.
adversely impact upon other premises infrastructure; and the infrastructure
by— has the capacity to accept any additional
i) causing ponding on the site or loading;
nearby land; AND