Original source · versioned page text
Town Planning Assessment Report
Very large file: it may take a few minutes
The original of this document is very large (15.9 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
4. incorporate preferred however if not
materials, finishes practical, buildings should at
and colours that least be well maintained and/or
complement the visually screened.
natural setting and
integrate with the
landscape and
skyline.
5.3.2 LOW DENSITY HOUSING CODE
The purpose of the Low density housing code is to ensure dwelling houses, community residences,
rooming accommodation and short term accommodation (where no more than one detached dwelling
on the site);
1. are appropriately located;
2. achieve a high level of comfort and amenity for occupants;
3. maintain amenity and privacy of neighbouring residential premises; and
4. are compatible with the character and streetscape of the local area.
The proposed development seeks to protect the existing environmental and landscape values by siting
the development within the existing cleared area.
The Landscape Rehabilitation Plan within the Ecological Assessment Report prepared by Greentape
Solutions nominates four rehabilitation areas throughout the site. New landscaping is provided along
side and throughout the site such that the future development of adjoining development to the east
will ensure adequate privacy. The site to the west is zoned as Environmental Management and
Conservation.
The proposal has been assessed against the code and is considered to achieve compliance with the
exception of AO21, which is addressed below.
Performance Outcome Acceptable Outcome Response
Earthworks and Drainage AO21 Complies with PO21
PO21 Filling other than accessways: The proposal results in >500m2
of excavation. Refer to the
Earthworks and drainage 1. does not extend more than
the equivalent of 3 metres Geotechnical Investigation
operational works do not
around the main building, prepared by Arcos Group.
directly, indirectly or
cumulatively cause adverse measured from the outer
impacts external to the walls of the building;
development site by: 2. is limited to a maximum of
1.causing ponding of water on 500m2; and
the site or nearby land; 3. does not impact on the local
2.increasing flooding, which drainage of adjoining
adversely affects the safety properties.
or use of any land upstream
and downstream;
3.adversely affecting the flow
of water in any overland
flow path; and
4.adversely affecting the
15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.