Log in to see the plans as drawn .|.
5
.|. .|. .|. .|. .|. .|. .|. .|. .|. .|. .|.
RP890947
.|. .|. .|.
.|. .|.
.|. .|.
4.00
4 5 SELECTIVE CLEARING ONLY
WITHIN FIRE BUFFER IN
3.290
3
3.219
ACCORDANCE WITH APPROVED
BUSH FIRE MANAGEMENT PLAN
NOMINAL 4.00m WIDE
VEHICLE ACCESS TRACK
G R A
R
0 FFE
6.0 BU
IRE
S HF
BU
S S T
7
RP890947
R E E
LOCATE NO GO FENCING ON
PROPERTY BOUNDARY
RAC SITE 61
6
RP901384
17
12
16
C O U
15
14
28 27
R T
8
RP901384
LEGEND TRUNK PROTECTION
BUFFER (12xØ OF TRUNK)
PROPOSED WORKS EXISTING FEATURES 3.60m TYPICAL
PROPOSED LIMIT OF WORKS EXISTING KERB AND CHANNEL WEEDING NOTE:
PROPOSED NO GO FENCING EXISTING ROAD CENTRELINE CONTRACTOR TO PROVIDE COUNCIL WITH A PROCEDURE TO ENSURE THE TREE TRUNK 0.30m
SITE IS DOES NOTE BECOME WEED INFESTED AND CONTAINS ANY OUTBREAK TYPICAL
PROPOSED AREA OF CLEARING AND GRUBBING EXISTING SEWERMAIN INTERNALLY TO THE SITE WITHOUT AFFECTING EXTERNAL LAND.
PROPOSED AREA OF GRUBBING ONLY EXISTING SEWER RISING MAIN TREE SYMBOL (SHOWN
PROPOSED DIRECTION OF CLEARING AS PER EXISTING TELECOMMUNICATION INDICATIVELY)
ECOLOGIST REPORT -
EXISTING UNDERGROUND ELECTRICAL
BUSHFIRE BUFFER/FIRE TRAIL
EXISTING WATERMAIN NOOSA COUNCIL PROPOSED NO GO FENCING
EXISTING STORMWATER APPROVED PLAN
EXISTING TREE TO BE RETAINED, PROVIDE
28 AN OFFSET OF 12x TRUNK DIAMETER FOR OPW18/0341 22 MAY 2020
PROTECTION BUFFER, REFER ECOLOGIST
REPORT FOR FURTHER DETAILS RETAINED TREE KEY DETAIL
FILE: 5001-102.dwg DATE: 13-12-2018 USER: NICK VENESS
XREFS: X-18-001942-TITLE, X-18-001942-5001-BASE, X-18-001942-SURVEY, X-18-001942-5001-TREES
DESIGN DRAWN CHECK APPROVED DATE STATUS SCALE CLIENT PROJECT DRAWING TITLE
FIRST AMENDMENT DETAILS Calibre Professional Services (QLD) Pty Ltd
ISSUE CB NV SD SP
FOR APPROVAL Level 3, 16 Innovation Parkway BLUE CARE SUNRISE BEACH TREE RETENTION
A CB NV SD SP 18.12.18 DIRECTION OF CLEARING ADDED Birtinya QLD Australia 4575
A
M B CB NV SP SP 19.12.18 FOR APPROVAL NOT FOR CONSTRUCTION 0 2.5
5 10
5 7.5
15 10
20 12.5
25 15
30 17.5
35 20
40
Telephone 07 5314 2520
Facsimile 07 5314 2522
RETIREMENT LIVING & AND CLEARING PLAN
E
C CB NV SP SP 02.08.19 FIRE TRAIL AMENDED
N
D
M D CR NV SP SP 08.04.20 BASIN AMENDMENTS
APPROVED SCALE 1:250
1:500 (A1) SCALE
SCALE1:1000
1:500 (A3) AGED CARE
E BY: SHAUN PILCHER RPEQ 14593 DISCLAIMER
PROJECT No. DRAWING No. REVISION
E
N ALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTOR
F
T
S
G SIGN: DATE: 08.04.20
C calibregroup.com PRIOR TO CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY,
DO NOT SCALE.
18-001942 5001-102 D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.