WINDOW & DOOR SCHEDULE
KEY NOTES All doors and window sizes are approximate and are to be checked on site.
All doors and windows in powder coated aluminium.
N
MFR METAL FLAT ROOF NGL NATURAL GROUND LEVEL · RL'S ARE ASSUMED ONLY AND SHALL BE VERIFIED BY BUILDER PRIOR TO
COMMENCEMENT OF SITE WORKS Use safety glass to bathroom and other areas as required.
MPR METAL PITCHED ROOF FGL FINISHED GROUND LEVEL · DOWN PIPES & ROOF DRAINAGE LOCATIONS ARE SUGGESTED ONLY AND BUILDER All glass to be clear unless state otherwise.
SHOULD ENSURE ADEQUATE STORMWATER FALL AND DRAINAGE AS REQUIRED All glass type and thickness to be in accordance with AS1288.
FR CONCRETE FLAT ROOF RL FINISHED LEVEL
· VERIFY SIZE OF ALL ROOFS ON SITE Set windows and doors to 2650mm or 2400mm unless noted otherwise.
DP DOWN PIPE All doors and windows as per engineer's wind load requirements.
All doors and windows to use subsills.
RH RAINHEAD ** All measurements are height x width.
FALL DIRECTION
WINDOW & DOOR SCHEDULE TO FUTURE SPECIFICATIONS.
A
)
HWM
0 (O
/ 26.9
'25"
8 56
o
2610
DP
ER
GUTT
W DP
BELO
EVEL
OF L
LINE
DP
2500
5deg
MFR
04
o 26'25"
/ 52.3 DP MFR
5deg
11 GUTT
ER
DP 0
DP 0.15
RL1
5deg
MFR
MFR
MFR 5deg
.9 00 5deg
5deg
L9
MFR
R
MFR
5deg
DP
5deg
MFR
DP DP
E R
GUTT
DP
W
EL BELO
OF LEV
LINE
FR
.9 00
R L8
FR
ER
GUTT
FR
B ELOW
EVEL
OF L
LINE
HOL E DP DP
S PORT
GLAS
294o55'25" / 20.117
5deg
MFR
FED
ROO
TERP ITH MFR
E WA W
TO B RDANCE 4.2
5deg
O F 5
RO CO 46
IN AC 54.1 & AS 0
AS 4
6
0 .05
R L1
.900
MFR
L8
5deg
MFR
R 5deg DP
FR
5deg
MFR
DP
00
9.9
MFR RL MFR
FR
5deg 5deg DP
DP RH
DP DP
5deg
MFR
DP ER
GUTT
DP
DP
DP DP
DP
LINE OF LEVEL BELOW
DP DP DP RH
DP RH
DP DP
RH RH
2525
)
2511
32.70(OHWM
199 32'25" /
o
204o55'25" / 58.741
A
ROOF PLAN
PAUL CLOUT DESIGN GENERAL NOTES:
Suite 3, 44 MARY STREET, NOOSAVILLE Use written dimensions only. DO NOT scale drawings. Contractors to verify all dimensions on site prior to REVISION DATE REV DESCRIPTION
CLIENT NAME: Offermann, Tom & Nicole
PO BOX 152, NOOSAVILLE, QLD 4566. commencing works. Site location is Category W41 or to engineer's requirements. These drawings are to be SITE ADDRESS: 98 Hilton Terrace, Noosaville 25/05/2026 A CLIENT ISSUE
BSA LICENCE: 1066417 read in conjunction with engineer's design and details, the accompanying building specification and schedule
PH: (07) 5440 5388
of finishes. If in doubt, please request clarification. DO NOT ASSUME.
@COPYRIGHT PAUL CLOUT DESIGN PTY LTD.
DRAWING TITLE:
STAGE:
Roof Plan
Council Drawings
A
[email protected]
www.paulclout.com
NOT FOR CONSTRUCTION SCALE: 1:100 ON A1 DRAWING No. 03.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Proposal Plans - 98 Hilton Terrace, Noosaville.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.