Parapet flashing to builders detail. Colorbond Custom orb roof sheeting
41.03 m 8m Height Limit (Appro fixed to manufacturers specification
600 x.) for required wind category. (5° pitch).
Select 50 x 50 P.C. Aluminium batten
screen @ 100 crs to manufacturers Framed extrusion to engineers detail
detail. 1600mm high. with EPS rendered and painted over.
Aluminum framed windows
to manufacturers specification.
Ceiling Height
2700
Joinery
Colorbond trimdek roof sheeting
2400
fixed to manufacturers specification
for required wind category. (2° pitch).
7330
Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
specification.
Ceiling Height
2700
Selected concealed panel lift door fixed to
Joinery
2400
manufacturers specification.
Select feature timber cladding to
manufacturers specifications.
Scyon Axon 133 (Or similar)
783
cladding to manufacturers detail.
Feature beam to engineers detail with
selected EPS sunhood/feature fixed to Approx. Proposed Ground Line.
beam to manufacturers specification. Approx. Existing Ground Line.
Built in feature planter - TBC
WEST ELEVATION
Scale : 1 : 100
600 Parapet flashing to builders detail.
x.) 600 800
Select 50 x 50 P.C. Aluminium batten 8m Height Limit (Appro
screen @ 100 crs to manufacturers
detail. 1600mm high. Framed extrusion to engineers detail
with EPS rendered and painted over.
1600
1300
Ceiling Height
Roof Terrace
2700
Joinery
2400
2230
1500 - Sill
Scyon Axon 133 (Or similar) Rendered foamboard cladding
cladding to manufacturers detail. to manufacturers specifications.
7330
Feature beam to engineers detail with
selected EPS sunhood/feature fixed to
beam to manufacturers specification.
Ceiling Height
Aluminum framed windows
2700
Joinery
Retained Max Fence Height
to manufacturers specification.
2400
2000
910
Approved frameless glass pool fence to
manufacturers specifications.
Rendered brick veneer
Min. 1200mm high.
walls to engineers details.
-
Approx. Existing Ground Line. APPROVED PLANS
DBW21/0063
Approx. Proposed Ground Line.
NOOSA COUNCIL
NORTH ELEVATION 23 JULY 2021
-
Scale : 1 : 100
Revision Schedule Client Name: RLH Homes
Sheet Number: 05 Project Number:20-040
Revision Number Revision Description Revision Date Issued by Project Address: 4 Ventura Street, Sunrise Beach
Climate Zone: 2
Wind Category: To engineers spec.
Elevations
Email: [email protected]
Website: www.iconbuildingdesign.com.au Project Issue Date: 24/05/2021 Project Status: PCD 13.1 Scale: 1 : 100
Phone: 0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: Aaron Waters QBCC LIC# 126221
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.