Stage, it is important that they are considered Prior to obtaining a Maternal Change of
Use approval, as they may impact on the proposal.

Comment: The applicant Traffic engineer has responded as follows:

A report outlining the compliance with the driveways and parking code is attached. In regard fo the
existing services code, there are no extensions impacting on existing or proposed services. The
existing stormwater pit located in the kerb on Ferguson Street adjacent to the existing driveway will
remain. Further details regarding water reticulation and sewerage will be provided at detailed design
with the Operational Works. In regard to the Transport, Roads & Drainage Code, the proposed
development will not generate significant traffic on the external road network. As shown in the survey
data obtained from the existing site, guests utilise the shuttle bus service, with very few guests arriving
with a car. The hostel is well located for tourist activities and provides excellent options for alternative
modes of transport to reduce car trips on the local road network.

Item 13: Please demonstrate that sufficient rainwater tanks will be provided on site to
service the toilets in the new building and the landscaping areas. To this end the
overall tank(s) capacity should be based on 12 litres/rn2 of roof area or at least one
5000-litre tank, whichever is the greater.

Comment: Amended plans are provided that demonstrate the location of rainwater tanks on site.
These tanks are located at the rear of the site.

Item 14: Provide drainage assessment prepared by a qualified registered engineer to estimate
the depth of stormwater ponding on the site during the 1 in 100 Average Recurrence
Interval (ARI) storm event and demonstrate what measures (such as raised floor
levels, waterproof flooring etc) to be implemented on the development site to alleviate
flooding of the premises during 1 in 100 year ARI.

Comment: The applicant has submitted numerous complaints to Council over the years as to the
problems associated with stormwater ponding in the street and flooding the subject site. The
photographs below detail recent flooding of Ferguson Street and demonstrates that the existing
stormwater systems are not able to cope with the flows of the surrounding area.

 

Used in these records

About this file

File size
3.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0299 - Response to Information Request [As Published].pdf · 3.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.