Annexure E Community Code

Attached to the e-mail Planning report & IDAS Forms, Annexure A,B,D,E,F,G - Email 1 of 2 MCU17/0035.

of 8

Page text shows just the words. Original shows the document exactly as it was published.

Annexure E – Community Uses Code



                                                  c) hardy vandal proof materials and
                                                  anti-graffiti paint are used in the
                                                  construction of buildings, where
                                                  appropriate

O15 Lighting of appropriate intensities is    S15.1 Lighting of appropriate intensities   Proposal able   to   comply   with
provided to maximise safety.                  is provided which satisfies the             requirements.
                                              requirements of Australian Standard
                                              AS1158: Public Lighting Code, unless
                                              otherwise specified in this Code;
                                              AND
                                              S15.2 External lighting of a graduated      Proposal able   to   comply   with
                                              intensity is provided which starts at a     requirements.
                                              lower level of brightness at the
                                              perimeter of the site and rises to a
                                              greater intensity at the entrance to
                                              buildings, or at the centre of the site;
                                              AND
                                              S15.3 Lighting is directed onto the site    Proposal able   to   comply   with
                                              and away from neighbouring properties;      requirements.
                                              AND
                                              S15.4 Vandal-resistant lighting is used     Proposal able   to   comply   with
                                              in public and publicly accessible areas.    requirements.

O16 Public toilets are designed and           S16.1 Features that may legitimise          Complies
constructed to:                               loitering, such as seating or public
a) ensure the safety of all people using      telephones are not located in proximity
them; and                                     to toilet entrances;
b) take advantage of informal surveillance    AND
from adjoining uses and activities,           S16.2 Public toilets are located in high    Complies
discouraging non-legitimate uses              traffic areas;
                                              AND
                                              S16.3 Entrances to public toilets are       Complies
                                              visible from the street, footpath and
                                              other activity areas on the site or
                                              adjoining sites

Mechanical plant and equipment and
storage Areas                                 S17.1 Mechanical plant and equipment        Proposal able   to   comply   with
O17 Mechanical plant and equipment            are—                                        requirements.
(including air conditioning equipment) and    a) located more than 2m from any
storage areas are designed and located        property boundary;
to—                                           b)where located at ground level,
a) avoid adverse visual impacts when          screened by fencing 1.5m in height or
viewed from the street and adjoining          dense vegetation of at least 1.5m in
properties; and                               width incorporating grouped trees and
b) be visually integrated with the building   shrubs with maximum separation
design                                        distance of 1m measured from the
                                              centre of the tree or scrub; and
                                              c) visually integrated into the line and
                                              plane of the building
                                              and roof design and do not project
                                              beyond the height or width of the
                                              building when viewed from the street
                                              and adjoining
                                              properties.




Noosa Council                                                                                                      Page 4
Log in to download the original file

Annexure E Community Code.pdf · 80 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.