Original source · versioned page text
Approved Plans MCU18/0120, RAL18/0013, OPW18/0197
Plans and drawings: the text below has words only, no drawings.
Very large file (16.0 MB): may take a few minutes to open.
Original PDF page 27, section 1. The text section number identifies this passage in the reader.
Stormwater pit as Pavement
detailed
Block retaining wall
Refer typical section
Vegetation. Refer 'Rat Flap' to
landscape Architect. manufacturers Stormwater pipe as
200 min
specs
depth
detailed
Bio-basin #3 Bio-basin #2 Bio-basin #1
- Surface Area = 100m2 - Surface Area = 64m2 - Surface Area = 81m2
- Filter Area = 45m2 - Filter Area = 32m2 - Filter Area = 37m2
Existing boulder
retaining wall
Fence to builders details Existing ground
Sandstone retaining wall.
1 1 Surface level of retaining wall 900 sq overflow pit with Typical.
2.25 200 base 2.25 Fence to builders details to match overflow pit. Typical. raised grate. Typical.
1 in 2 batter.
Typical.
Block retaining wall S.L. - 119.00
Refer typical section S.L. - 118.40
S.L. - 117.80
Rock scour protection at
pit locations Existing ground
I.L. - 116.94 450Ø RCP at 1.5%
I.L. - 116.30 450Ø RCP at 1.5%
Inert level of existing
SECTION 1 Stormwater line to be SECTION 2
confirmed on site.
Scale 1:20 at A1 C03 Scale 1:200 at A1 C03
TYPICAL VEGETATED TYPICAL BIO-RETENTION BASIN LONGITUDINAL SECTION
SWALE SECTION
150 900mm Class 'B' 150 NOTE: Grate to be 990 square hot
dip galvanised. with 10 side
50 50 plates and 50x6 bars at 50 crs.
150 900sq Class 'B' 150
U.N.O
150
150
50
Grate
300
Screw cap and concrete surround Vegetation to comply with the requirements of
flush out point. 45° bend. Refer to appendix 'A' of 'Healthy Waterways Water
10 diameter rod Sensitive Urban Design' to loamy soils. Refer
900mm Class 'B'
WSUD-003 for details.
welded to bars landscape architects details.
MCU18/0120 RAL18/0013 OPW18/0197
50
Sandy loam. Hydraulic conductivity 200mm/hr in
150
accordance with 'Guideline Specification for Soil Media in
Bioretention Systems, Facility for Advancing Water
Biofiltration.' Soil orthophosphate content not to exceed
500
APPROVED PLAN
NOOSA COUNCIL
55mg/Kg. Certification to be provided.
21 NOV 2018
100 diameter slotted uPVC pipes. Discharge to inlet
pit. Provide 100mm Diameter capped uPVC flush out
100
points at 10.0m (min) crs.
200
PLAN
-
150
Stormwater pipe as 100 diameter slotted uPVC pipes at 0.5% Geofabric to be provided Course sand 5mm screenings
detailed minimum grade. Discharge to outlet pit. around bioretention media transition layer
Provide 100mm Diameter capped uPVC flush
out points at 2.5m (max) cts.
SECTION
BIORETENTION RAISED GRATED PIT DETAILS TYPICAL BIORETENTION SECTION
SCALE 1:20 AT A1 SCALE 1:20 AT A1
PIT NUMBER PIT NUMBER
1/1 2/1 3/1 4/1 5/1 6/1 7/1 8/1 OUTLET 9/1 1/5 2/5 3/5 OUTLET 4/5
PIT NUMBER PIT NUMBER PIT NUMBER
300mm sq with 600mm sq with 600mm sq with 600mm sq with 600mm sq with 600mm sq with 600mm sq with 600x900 with Discharge into 300mm sq 600mm sq 600x900 Discharge into
DESCRIPTION DESCRIPTION
D-Class Grate D-Class Grate D-Class Grate D-Class Grate D-Class Grate D-Class Grate D-Class Grate D-Class Grate bio-retention 1/2 1/3 2/3 3/3 4/3 5/3 6/3 1/4 2/4 3/4 EXISTING 4/4 bio-retention
basin basin
121.35 120.80 120.80 120.80 120.80 120.80 120.80 120.38 600mm sq with 600mm sq with 600mm sq with 600mm sq with 600mm sq with 600mm sq with 600mm sq with 900mm sq 900mm sq 900mm sq T.B.C. 121.45 121.05 120.30
SURFACE DESCRIPTION DESCRIPTION DESCRIPTION overflow pit overflow pit overflow pit
SURFACE
D-Class Grate D-Class Grate D-Class Grate D-Class Grate D-Class Grate D-Class Grate D-Class Grate
LEVELS with raised grate with raised grate with raised grate LEVELS
120.86 120.32 120.40 120.40 120.40 120.40 120.40 119.00 118.40 117.80 T.B.C.
119.200
119.000
118.620
118.230
117.850
INVERT LEVEL SURFACE SURFACE SURFACE INVERT LEVEL
LEVELS LEVELS LEVELS
STORMWATER PIT DETAILS - LINE 1 STORMWATER PIT DETAILS - LINE 2 STORMWATER PIT DETAILS - LINE 3 STORMWATER PIT DETAILS - LINE 4 STORMWATER PIT DETAILS - LINE 5
Issue Made By Date Description PROPOSED COMMERCIAL DEVELOPMENT Scale : 1:20 AT A1 U.N.O. NOTES:
0 PC 06/07/18 Preliminary ONLY - for DA Approval
at NO. 5 TAYLOR COURT, COOROY
REVISION
A PC 06/07/18 Issue for BA Job No.: 18-0165 1. Do not scale drawings.
2. Scale is correct at A1.
B PC 19/10/18 No changes to sheet. Re-issue CLIENT: HASS HOLDINGS PTY LTD
Dwg No.: C04 3. Check and verify all dimensions
C PC O6/11/18 Bio-basins updated Designed By : B.J. WINNING BEngTech (Civil) Drawn By : PC Date : 29/05/18 prior to commencement of work.
D BJW O7/11/18 General amendments Certified By : B.R. CROMAR BEng (Civil), MIEAust, CPEng, RPEQ, NPER Date : 11/09/18 Ph: (07) 5444 5578 Email: [email protected] STORMWATER DRAINAGE DETAILS