N13078 - 2014.10.17 - 1 Of 2
Attached to the e-mail OPW14/0197 - Amended Plans for Approval (Email 1 of 5)..
REFER DRG N13078-112 FOR CONTINUATION
i i i I at 140
NOTE: s INDUSTRIAL ip I) FOL ol
REFER TO N13078-110 FOR ROADWORKS 2 129 STRENGTH ay | IE S|
AND DRAINAGE NOTES AND LEGEND. oS CROSSOVERS REFER ROOFWATER Pass 4s o
= EXISTING 525B RCP. 5 128 SWALE DETAIL. 4 2
a. |? AY J LOT 904
DANGER !! CAUTION Ii = } 160 SP 221501
Aree =
N UNDERGROUND OOo eereaN? . Ke)
ELECTRIC CABLES CABLES a FUTURE
— io DEVELOPMENT
qelstra = 0
energex a
UNDERGROUND ELECTRICITY UNDERGROUND TELECOMMUNICATION !
CABLES EXIST IN THIS VICINITY. CABLES EXIST IN THIS VICINITY. CONSTRUCT NEW MANHOLE 6008
CONTACT ENERGEX FOR CABLE CONTACT TELSTRA FOR CABLE OVER EXISTING 525@ RCP. 1
LOCATIONS. EXTREME CARE MUST LOCATIONS. EXTREME CARE MUST
BE TAKEN WHILST EXCAVATING. BE TAKEN WHILST EXCAVATING. DEMOLISH AND REMOVE 1@)
REMAINING PIPE AND
HEADWALL DOWNSTREAM 200
E @
I
INDUSTRIAL
STRENGTH
/ CROSSOVERS
EXISTING [email protected]
CONSTRUCT NEW MANHOLE OVER.
EXISTING 375@ RCP. DEMOLISH
AND REMOVE REMAINING PIPE
AND HEADWALL DOWNSTREAM
INDUSTRIAL
STRENGTH
CROSSOVERS
SLhN
Md
YSTAGE C5E
PROVIDE 4.0m? ROCK
PROTECTION Dsp =
200mm L = 2.0m
PROVIDE 4m? ROCK
PROTECTION Dsp =
200mm L = 2.0m
BECKMANS
GREEN
LOT 900 ry
EXISTING SEWER 9 ~
SP22150
PROVIDE 13.0m? ROCK PROTECTION
Dsp = 200mm L = 3.5m
DEMOLISH AND REMOVE EXISTING
REFER N13078-130 FOR
BASIN ACCESS DETAILS.
&4
ROAD AND GULLY PITS
EXISTING 2/1200 CULVERT
FOOTPATH TO JOIN TO
EXISTING NEATLY
JOIN NEATLY TO EXIST
6.5m CARRIAGEWAY
Y
EN Ss, *
~ ‘SV
N
K Q
x ow é
PER S ay
Noo
REFER OUTLET THROUGHSSPROVIDE 4.0m? ROCK
ROCKWALL DETAIL ON PROTECTION Ds9 =
DRG. N13078-131 200mm L = 2.0m
PROVIDE 4.0m? ROCK
PROTECTION Dep =
200mm L = 2.0m
REFER I.P.W.E.A.Q, STD. DRG.
WSUD-006 FOR WEIR DETAILS
DANGER !!
UNDERGROUND
ELECTRIC CABLES
V2...
UNDERGROUND ELECTRICITY
CABLES EXIST IN THIS VICINITY.
CONTACT ENERGEX FOR CABLE
LOCATIONS. EXTREME CARE MUST
BE TAKEN WHILST EXCAVATING.
CAUTION II
UNDERGROUND
TELSTRA
CABLES
qelstra
UNDERGROUND TELECOMMUNICATION
CABLES EXIST IN THIS VICINITY.
CONTACT TELSTRA FOR CABLE
LOCATIONS. EXTREME CARE MUST
BE TAKEN WHILST EXCAVATING.
EXISTING DEVELOPMENT
S
REFER N13078-124 FOR >
ISLAND SETOUT DETAILS 2 ,
g ; Ky bs °
va \ ° he 8 \ PL LY oor
eS v \ 157 SS é 1 our va
/ TVR SQA te KZ, Xt
pt HCNTDHTSST ACNBITACOASE XCNIBOTE ROADWORKS AND DRANAGE X-NEOTE-CONTOURS USR: Curtis Baoan REFER DRG N13078-110 FOR CONTINUATION
IC SONTE TMETREST TCHR Ne ENT TAR TTT
AMENDMENT DETAILS DESIGN CHECK SURVEYOR: RPS
meee fx | wae 1 INNOVATION PARKWAY, BIRTINYA QM PROPERTIES conus ROADWORKS AND DRAINAGE
AIAT LF LF | 28.05.14 | FOOTPATH AMENDED, PIPE SHOWN AND SWD GULLY G22/Y REMOVED Ph (07) 5436 7888 Fi (07) 5493 6630
E B | nt _[ nt | 30.06. [ORVEWAY FOR LOT 135 ADDED. 1500 1 5 0 0 Al ox PROJECT Sd LAYOUT PLAN
plc] AT NT | 05.08.14 J BIO SWALE ADDED, SWD AND FOOTPATH WIDTHS AMENDED. ee SS eee PROJECT No. “APPROVED
Ho @-| oan [aONENTS FEY ANGLO RED, SRE OME REED] PMY 000 8 SUNN ta ice] LAKE DOONELLA NOOSA awning LOD aa SHEET 2 OF 3
? en S tC Ini 3,1 sa Ry, iy UDA 55 DRAWING NOMGER Soe
Nie N13078 BRENT THOMAS RPEQ 7862 IMATE CONSUMING dose 0754709260 cide 0734709282 BONE
: STAGE C1 - C6 bea in ae N13078-111 D
Slr FOR & ON BEHALF GF BROWN CONSULTING (QLD) PTY LTD (Mrotane Conbarm Mehours Spivey rgepere Sunetine Cemt Lc 484