Skip to the record
Accept no imitations.

Council archive · source document

Attachment 4 - Geotech Report · MCU23/0030

of 59

Text shows just the words. Original shows the document exactly as it was published.

Comments

Sample Integrity
Custody Seals Intact (if used)                                                                                                          N/A
Attempt to Chill was evident                                                                                                            Yes
Sample correctly preserved                                                                                                              Yes
Appropriate sample containers have been used                                                                                            Yes
Sample containers for volatile analysis received with minimal headspace                                                                 Yes
Samples received within HoldingTime                                                                                                     Yes
Some samples have been subcontracted                                                                                                    No




Authorised by:

 Zoe Flynn                               Analytical Services Manager
 Jonathon Angell                         Senior Analyst-Inorganic
 Jonathon Angell                         Senior Analyst-Metal
 Scott Beddoes                           Senior Analyst-Inorganic




Glenn Jackson
General Manager


Final Report – this report replaces any previously issued Report


- Indicates Not Requested
* Indicates NATA accreditation does not cover the performance of this service
Measurement uncertainty of test data is available on request or please click here.
Eurofins shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this
report. In no case shall Eurofins be liable for consequential damages including, but not limited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This
document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.




                                                           Eurofins Environment Testing 1/21 Smallwood Place, Murarrie, QLD, Australia, 4172                                            Page 6 of 6
   Date Reported: Jan 24, 2023                                             ABN : 50 005 085 521 Telephone: +61 7 3902 4600                                              Report Number: 955949-W

Used in these records

About this file

File size
6.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 4 - Geotech Report.pdf · 6.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.