Original source · versioned page text
RFI - Attachment 7A - Response to Bushfire Issues and BMP.pdf
12
6.3 ACCESS
7. As there are constraints with the existing vehicle access, into the site, improvements to
the Resort Drive verge the removal of vegetation from along the edge of the road to
extend the width of accessible road reserve is required. This will improve sightlines and
impacts of vegetation with resident vehicles and emergency vehicle response.
6.4 WATER SUPPLY
8. We believe the existing facility is connected to reticulated water and this will be sufficient
for the proposed hotel. However, the hydraulic engineering consultants should ensure
there is the capacity to meet potential needs should a structural and/or vegetation fire
threaten the structures.
9. Sufficient hydrant standpipes or inground hydrants are to be located within and around
the facility to ensure compliance with relevant guidelines and standards.
10. It is noted that the golf course also has extensive irrigation separate from the reticulated
supply, sourced from a local lake, and this could be channelled into an auxiliary supply
for bushfire purposes. However, we note that this water may not meet the QFES
specifications for us to suppress vegetation fires via pressure hoses and should be used
by aerial appliances.
6.5 FUTURE PLANNING
11. A bushfire management plan will be required due to the facilities proximity to identified
bushfire hazard areas.
12. The Hotel is to designate an in-house Fire Response Chief whose responsibility will be
to provide direction to guests and staff should a bushfire threaten the hotel.
13. An emergency response plan which will include an Evacuation Plan should also be
considered to provide a set of responses should a vegetation fire involve adjacent
vegetation and visitors and staff need to be relocated to ensure they are safe until the
fire is brought under control by the relevant authorities. This evacuation procedure
could involve one or more of the following;
a. evacuation onto the golf course.
b. evacuation within the community titles area, located behind buildings with fire
safety standards.
c. Within the hotel, the evacuation of visitors and staff to the reception area, to wait
for further instructions by the Hotel Management or Emergency Services.
Bushfire Management Plan | Noosa Springs | RFA17-040 24 September 2021