Council archive · source document
Approved Plans - MCU13-0081.02 · MCU13/0081.02
Plans and drawings: the text below has words only, no drawings.
Very large file (16.2 MB): may take a few minutes to open.
Original PDF page 22, section 1. The text section number identifies this passage in the reader.
REV DESCRIPTION DRN DATE
A MCU DA Issue MS 25.02.20
B MCU DA Issue MS 02.03.20
C MCU DA Issue MS 06.03.20
D Client Revisions MS 14.04.20
E MCU DA MS 05.08.20
Information Response
200 x 50 powdercoated aluminium F GIA Issue MS 07.04.21
awning frame supported by -
G GIA Variations MS 24.06.21
reinforced concrete blade columns.
Provide 50 x 20 battens to
GENERALLY IN ACCORDANCE H GIA Variations MS 11.08.21
underside of frame, select
polycarbonate roof sheeting over
APPROVED PLAN
MCU13/.0081.02
150 x 50 powdercoated NOOSA COUNCIL
aluminium batten screen
13 SEPTEMBER 2021
-
New frameless glass New 1200 mm high blockwork 100 x 25 powdercoated aluminium
balustrade and gate with wall with select mosaic tile finish. pergola frame fixed to slab edge
anodised aluminium uprights, Provide feature water spout / downturn. Horizontal member fixed
fixed to slab edge downturn waterfall effect to kids pool area to slab edge / upstand wall above
100 x 25 powdercoated aluminium
pergola frame fixed to slab edge
New blockwork wall
planter. Top of wall to be
New outdoor shower area.
Select new fixtures to
Generally throughout:
downturn. Horizontal member fixed
to slab edge / upstand wall above
level with timber decking connect to existing plumbing - New render and paint finish to all external walls
- New anodised aluminium (25µm coating)
New concrete pavers / sliding doors to terraces / balconies
Feature timber seat
stepping stones on gravel bed - New anodised aluminium (25µm coating) windows
with downlighting
connecting basement stair,
under to future detail - New frameless glass balustrade with
entry and outdoor shower
anodised aluminium (25µm coating) uprights
- New tiles to walkways, terraces and balconies
Suite 2,
100 x 25 powdercoated aluminium
pergola frame fixed to slab edge Cnr Gard
downturn. Horizontal member fixed Alexand
to slab edge / upstand wall above
PO Box
New concrete pavers / 200 x 50 powdercoated aluminium awning frame
New frameless glass pool fence P 07 54
stepping stones on gravel bed supported by reinforced concrete blade
connecting basement stair, columns. Provide 50 x 20 battens to underside
and gate on anodised aluminium admin@
spigot fixings to future detail
entry and outdoor shower of frame, select polycarbonate roof sheeting over
5°
SUNCOAST RESORT BUSINESS CENTRE
5°
SUITE 2 CNR GARDAK ST & SURF RD
TL-01c - 'Eco Outdoor' Fallow Granite (P5 New pool overflow grate. ALEXANDRA HEADLAND Qld 4572
Red hatched area indicates TL-06 - 'The Tile Company' Fingal CMC slip rating), 800x400x20mm, face 300mm longitudinal 'Daldorado PO BOX 6232 MAROOCHYDORE BC Qld 4558
TOW RL 8.290 extent of existing pool (P5 slip rating), 48x8x6mm, pool tile to exfoliated pool coping tile to be laid over Wetdeck' grate as per pool PH : 07 5443 5028 FAX:07 5479 2380
upstands / blockwalls under be laid over waterproof membrane as waterproof sheet membrane as specified consultant's specifications and ABN 23 123 917 724
RF-A to be removed specified in Ardex specification in Ardex specification. Provide 15mm fall details. Refer to manufacturer EMAIL: [email protected]
away from grate towards pool edge drawings for installation guide
project
Pool terrace PROPOSED ALTERATIONS &
1350
BAL-PF1 BAL-PF1
ADDITIONS TO EXISTING
TGD
RESORT BUILDING
310
FFL 5.900 FFL 5.900
4 4
FFL 5.590 3 3 for
Kids Pool
steps
steps
3 eq.
3 eq.
RL 5.380
RF-A 2 2 NETANYA RESORT
approx.
Planter 1 1
950
Balance Tank Void Void at
BA TL-06 TL-06 Main Pool TL-06 RL 4.630
L-S
T3 75 HASTINGS STREET
NOOSA HEADS
drawing
Refer to pool consultant's
drawings for balance tank
Confirm RL of existing
pool slab on site Existing concrete pool shell and New reinforced concrete
DETAILED AREA - POOL
RF-A
and pool drainage details
podium slab. Ensure structural
New proprietary type
RF-A concourse structure and TERRACE / REAR ENTRY
stainless steel pool
Void
WT 1
Maintenance Carpark adequacy and check for, if support walls over existing
access handrails as per
present, extent of concrete podium slab as per
Hatched area indicates location of pool consultant's details
cancer / rusted reinforcement structural engineer's details
existing concrete piers. Refer to
existing structural drawings for details AS SHOWN
date 11/08/2021 drawn JP scale @A1
drawing no. 19021 SD60.05 revision H
Copyright of this document remains the exclusive
property of SPROUT ARCHITECTS PTY LTD
ABN 23 123 917 724.
SECTION C Contractors are to verify all dimensions and levels on
site prior to commencing. Report all discrepancies to
the Architect. Use figured dimensions in preference
Scale 1:50 0 5 10 to scaled.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU13-0081.02.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.