                                                                                              boundary
                                                                                                                      12.0m height limit
                                                                                                                             from flood                              metal roof at
                                                                                                                    design level shown                                      5° fall
                                                                                                                          dashed in red
+15.600
Stair Roof
               2,400




                                                                                                                                                                       +14.560 ridge


                                                                                                                                       8,000 s'bk
+13.200
Roof Tce


                                                                                                                               6,000 s'bk
               3,530




                                                                                                                                                                              U204


+9.670
Level 02
                                                                                                             2,500 s'bk
                                                                                                             to awning
                       THOMAS STREET
               3,370




                                                                                                          recycled timber
                                                                                                          pergola beyond                                                       U105
                                                                                                            'tide actuated'
                                                                                                         timber landscape
                                                                                                                 structures
+6.300
Level 01
               3,600




                                                                                                                                                           T3



+2.700
Ground Floor
               3,000




                                                                                                                                                                basement


-0.300
Basement


                                       existing verge                               stone                              ramp
                                        landscaping                                planter                            egress
                                                                                    beds



Section 03 - Thomas St



                                                                                                                         project                                 issue date            description   drawing name:   project no:
                                             6/ 9a Factory St, Pomona, QLD, 4568
                                                                                                                                                                 B     25/8/2026                                     2404
                                             P 0410 464 448
                                             E [email protected]
                                                                                                                         Mixed Use Development                                                       Sections
                                                                                                                         204 & 207 Gympie Tce Noosaville
                                             ABN 56 680 451 058
                                             Reg. No. 5601 (QLD)                                                         client                                                                      scale            drawing no:
                                             © all work subject to copyright and may not be
                                             reproduced without wri en permission.                                       Gympie Tce Pty Ltd                                 NOT FOR CONSTRUCTION     1 100 @ A3       4.03

Used in these records

About this file

File size
82.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

26.8.26 - Attachment 1 - Amended Proposal Plans (2).pdf · 82.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.