Council archive · source document
07/2382 - MCU - Detached House [As Published] · 132007.2382
wks
On. Vaadsv
1324m?
LOT52 §
t
’
--------------!
20.021
00mm Downpipes
Provide rainwater catchment from roof
5000 Litres of ram water storage Required
Refer Local Authority for details
regarding tank water allocation
Sewer lines , Sewer Access , Connection point, invert level and
site level information provided by others. MRA Design Is not
responsible for their accuracy.
‘ 6,000 6004, + O : © 17,020 417724
Site Plan
1:200
@senerar NOTES TERMITE PROTECTION CORROSION PROTECTION STANDARDS REFERENCE
LICENCED CONTRACTOR TO PROVIDE TERMITE BARRIER ALL METAL USED IN STRUCTURAL TIMBER DESIGN SHALL COMPLY TO ALL RELEVANT
ALL CONSTRUCTION TO COMPLY WITH THE TO PERIMETER OF SLAB AND ALL PENETRATIONS IN CONNECTIONS, SHALL BE PROVIDED WITH AUSTRALIAN STANDARDS & GENERAL
BUILDING CODE OF AUSTRALIA, ACCORDANCE WITH A.S 3660.1, PART 3.1.3 OF THE BCA CORROSION PROTECTION APPROPRIATE FOR BUILDING PRACTICE REFRENCES SOME
THE QUEENSLAND BUILDING ACT AND TO THE
REQUIREMENTS OF THE
LOCAL AUTHORITY.
SEWERAGE AND FLOOR WASTES TO DISPOSAL
. SYSTEM AS APPROVED BY THE LOCAL
AUTHORITY, AND IN ACCORDANCE WITH THE
SEWERAGE AND WATER SUPPLY ACT.
CONNECT DOWNPIPES TO STREET VIA 100MM
PVC PIPE OR AS REQUIRED BY THE LOCAL
AUTHORITY.
ENSURE THE GROUND LEVEL FALLS MIN 1:20 -
900mm AWAY FROM THE BUILDING LINE,
PROVIDE AND MAINTAIN EROSION AND
SEDIMENT CONTROL STRUCTURES TO
PERIMETER OF WORK AREA. .
DO NOT SCALE FROM DRAWING. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS,
SETBACKS, AND LEVELS OF SERVICES ON SITE,
BEFORE COMMENCING WORK . CONTRACTOR IS
RESPONSIBLE FOR MAINTAINING STABILITY OF
THE STRUCTURE UNTIL COMPLETION ANS SHALL
ENSURE THAT NO PART OF THE STRUCTURE IS
OVERSTRESSED 8Y CONSTRUCTION LOADING.
AND RELEVANT AMENDMENTS.
eATTACHMENTS TO BUILDING SUCH AS DOWN PIPES
MUST HAVE A NOMINAL GAP TO ALLOW CLEAR AND
UNINTERUPPTED VISUAL INSPECTION ACCROSS THE
INSPECTION ZONE. .
STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES,
ACCESS RAMPS, CARPORTS, TRELLISES, DECKS, HOT
WATER SYSTEMS, AIR CONDITIONERS, OR THE LIKE
WHICH ARE NOT PRIVIDED WITH ONE OF THE BARRIER
SYSTEMS DESCRIBED IN THIS PART, MUST BE
SEPARATED FROM THE BUILDING BY A GAP OF NOT LESS
THAN 25mm, TO ALLOW CLEAR AND UNINTERUPPTED
VISUAL INSPECTION ACCROSS THE INSPECTION ZONE.
WHERE ATTACHMENTS OR STRUCTURES AS OUTLINED
ABOVE ABUT A BUILDING AND THERE IS NO CLEAR GAP,
ABARRIER MUST BE PROVIDED TO THE ATTACHMENT,
REGARDLESS OF THE SIZE OF THE ATTACHMENT.
BARRIERS MUST NOT BE BRIDGED BY STRUCTURES,
FITTINGS OR OTHER ATTACHED TO THE MAIN BUILDING,
NOR SHALL THEY BE BREACHED BY THE INSTALLATION
OF SERVICE ENTRY POINT, DOWN PIPES ADDITIONAL
SLABS AND PATHS, LANDSCAPING, GARDENS OR
SIMILAR UNLESS ADDITIONAL BARRIERS ARE USED TO
ELIMINATE CONCEALED ACCESS BY TERMITES TO THE
STRUCTURE.
THE PARTICULAR CONDITIONS OF USE. WHERE
CORROSION PROTECTION OF STEEL IS
REQUIRED IT SHALL BE IN ACCORDANCE WITH
. ASINZS 4791, A.S. 1397 and A.S.1214, THE LEVEL
OF CORROSION PROTECTION PROVIDED SHALL
TAKE INTO CONSIDERATION WEATHER
EXPOSURE, TIMBER TREATMENT, MOISTURE
AND PRESENCE OF SALT.THESE SHALL
SATISFY THE REQUIREMENTS OF THE
RELEVANT AUTHORITY. WHERE OTHER TYPES
OF CORROSION PROTECTION ARE PROVIDED,
ENERGY EFFICIENCY
THESE PLANS ARE SUBJECT TO B.E.R.S. ASSESSMENT
INSULATION. NOTES :-
+ PROVIDE Min R2.5 TO CEILING.
+ PROVIDE MIN R1.5 TO EXTERNAL WALLS
-40% OF FLOOR AREA TO HAVE APPROVED
ENERGY EFFICIENT LIGHTING
-WATER HEATER TO BE AN APPROVED ENERGY EFFICIENT
GAS, SOLAR, OR HEAT PUMP INSTALLED BY LISCENCED
TRADESPERSON.
LISTED BELOW
BUILDING CODE OF AUSTRALIA 2006
AS1684.2 - 1999 - RESIDENTIAL TIMBER-FRAMED
CONSTRUCTION .
AS3600 - CONCRETE STRUCTURES
AS4100 - STEEL STRUCTURES
AS3700 - MASONRY STRUCTURES
AS3500 - WATER SUPPLY
AS37868 - SMOKE ALARM
AS3660 - TERMITE PROTECTION
AS1926 - POOL FENCING
CONSULTANTS.
REFER STRUCTURAL ENGINEERS SPECIFICATION FOR
© SOIL TEST / SITE CLASSIFICATION
@ SLAB AND FOOTING DESIGN
¢ TIMBER FRAMING + LINTELS
@ POOL DESIGN
REFER TRUSS MANUFACTURERS SPECIFICATION FOR
@ TIMBER TRUSSES AND ROOF FRAMING.
REFER ROOF CONTRACTORS SPECIFICATION FOR
¢ SHEET ROOF FIXING AND ACCESSORIES.
ae | acter
AN
WY
SITE PLAN
Lot: §2
eat
SP : 163309
Parish: Tewantin
County: March
Area: 1324m?
Building
FootPrint 317 m?
Site Coverage 23.94%
+
AREA SCHEDULE
Internal Floor Area - 277.5 ma
South Deck - 9.0 me
North Deck - 11.0 mz
Outdoor Pavillion 19.5 mz
Access decking 6.5 m2
Entry - 6.0 ma
Total Floor Area - 329.50 mz
y :
w oR A Dp
GQBBA Lic. No. 07044
Kawana Junct
1/33 Premior Circuit.
Queanstand 457
7
lon
3.
8
1
adesign.com.au
Gorn
RTC si]s)
Rate
Project Description
Bulking 8 Real Estate levesiment
Leach Development Group
Ce ee
Proposed Residence
alec
eee
CURA cuk Led
Site Address.
Aspera
Lot 52
~Noosa Retreat~
Place
ertton consent by the author.
hese drawings remain copyright of MRA Design
land may not be used in pest orn whole without
Scale; 1:200
States:
Drawn: RDG
Date: 6/07/2007
[Checked By:
Project No:
2007 - 063
[Shoet No.
01 of 8
pot Dats:
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2382 - MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.