07/2382 - MCU - Detached House [As Published] · 132007.2382

of 50

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

wks

 

 

On. Vaadsv

1324m?

LOT52 §

 

 

t
’
--------------!

20.021

00mm Downpipes

Provide rainwater catchment from roof
5000 Litres of ram water storage Required
Refer Local Authority for details

regarding tank water allocation

Sewer lines , Sewer Access , Connection point, invert level and

 

 

site level information provided by others. MRA Design Is not
responsible for their accuracy.

 

 

 

‘ 6,000 6004, + O : © 17,020 417724
Site Plan
1:200
@senerar NOTES TERMITE PROTECTION CORROSION PROTECTION STANDARDS REFERENCE
LICENCED CONTRACTOR TO PROVIDE TERMITE BARRIER ALL METAL USED IN STRUCTURAL TIMBER DESIGN SHALL COMPLY TO ALL RELEVANT
ALL CONSTRUCTION TO COMPLY WITH THE TO PERIMETER OF SLAB AND ALL PENETRATIONS IN CONNECTIONS, SHALL BE PROVIDED WITH AUSTRALIAN STANDARDS & GENERAL
BUILDING CODE OF AUSTRALIA, ACCORDANCE WITH A.S 3660.1, PART 3.1.3 OF THE BCA CORROSION PROTECTION APPROPRIATE FOR BUILDING PRACTICE REFRENCES SOME

THE QUEENSLAND BUILDING ACT AND TO THE
REQUIREMENTS OF THE
LOCAL AUTHORITY.

SEWERAGE AND FLOOR WASTES TO DISPOSAL
. SYSTEM AS APPROVED BY THE LOCAL
AUTHORITY, AND IN ACCORDANCE WITH THE
SEWERAGE AND WATER SUPPLY ACT.
CONNECT DOWNPIPES TO STREET VIA 100MM
PVC PIPE OR AS REQUIRED BY THE LOCAL
AUTHORITY.
ENSURE THE GROUND LEVEL FALLS MIN 1:20 -
900mm AWAY FROM THE BUILDING LINE,
PROVIDE AND MAINTAIN EROSION AND
SEDIMENT CONTROL STRUCTURES TO
PERIMETER OF WORK AREA. .

DO NOT SCALE FROM DRAWING. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS,
SETBACKS, AND LEVELS OF SERVICES ON SITE,
BEFORE COMMENCING WORK . CONTRACTOR IS
RESPONSIBLE FOR MAINTAINING STABILITY OF
THE STRUCTURE UNTIL COMPLETION ANS SHALL
ENSURE THAT NO PART OF THE STRUCTURE IS
OVERSTRESSED 8Y CONSTRUCTION LOADING.

 

AND RELEVANT AMENDMENTS.

eATTACHMENTS TO BUILDING SUCH AS DOWN PIPES
MUST HAVE A NOMINAL GAP TO ALLOW CLEAR AND
UNINTERUPPTED VISUAL INSPECTION ACCROSS THE
INSPECTION ZONE. .
STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES,
ACCESS RAMPS, CARPORTS, TRELLISES, DECKS, HOT
WATER SYSTEMS, AIR CONDITIONERS, OR THE LIKE
WHICH ARE NOT PRIVIDED WITH ONE OF THE BARRIER
SYSTEMS DESCRIBED IN THIS PART, MUST BE
SEPARATED FROM THE BUILDING BY A GAP OF NOT LESS
THAN 25mm, TO ALLOW CLEAR AND UNINTERUPPTED
VISUAL INSPECTION ACCROSS THE INSPECTION ZONE.
WHERE ATTACHMENTS OR STRUCTURES AS OUTLINED
ABOVE ABUT A BUILDING AND THERE IS NO CLEAR GAP,
ABARRIER MUST BE PROVIDED TO THE ATTACHMENT,
REGARDLESS OF THE SIZE OF THE ATTACHMENT.
BARRIERS MUST NOT BE BRIDGED BY STRUCTURES,
FITTINGS OR OTHER ATTACHED TO THE MAIN BUILDING,
NOR SHALL THEY BE BREACHED BY THE INSTALLATION
OF SERVICE ENTRY POINT, DOWN PIPES ADDITIONAL
SLABS AND PATHS, LANDSCAPING, GARDENS OR
SIMILAR UNLESS ADDITIONAL BARRIERS ARE USED TO
ELIMINATE CONCEALED ACCESS BY TERMITES TO THE

STRUCTURE.

THE PARTICULAR CONDITIONS OF USE. WHERE
CORROSION PROTECTION OF STEEL IS
REQUIRED IT SHALL BE IN ACCORDANCE WITH

. ASINZS 4791, A.S. 1397 and A.S.1214, THE LEVEL

OF CORROSION PROTECTION PROVIDED SHALL
TAKE INTO CONSIDERATION WEATHER
EXPOSURE, TIMBER TREATMENT, MOISTURE
AND PRESENCE OF SALT.THESE SHALL
SATISFY THE REQUIREMENTS OF THE
RELEVANT AUTHORITY. WHERE OTHER TYPES
OF CORROSION PROTECTION ARE PROVIDED,

ENERGY EFFICIENCY

THESE PLANS ARE SUBJECT TO B.E.R.S. ASSESSMENT
INSULATION. NOTES :-

+ PROVIDE Min R2.5 TO CEILING.

+ PROVIDE MIN R1.5 TO EXTERNAL WALLS

-40% OF FLOOR AREA TO HAVE APPROVED

ENERGY EFFICIENT LIGHTING

-WATER HEATER TO BE AN APPROVED ENERGY EFFICIENT
GAS, SOLAR, OR HEAT PUMP INSTALLED BY LISCENCED
TRADESPERSON.

LISTED BELOW

BUILDING CODE OF AUSTRALIA 2006

AS1684.2 - 1999 - RESIDENTIAL TIMBER-FRAMED
CONSTRUCTION .
AS3600 - CONCRETE STRUCTURES

AS4100 - STEEL STRUCTURES

AS3700 - MASONRY STRUCTURES

AS3500 - WATER SUPPLY

AS37868 - SMOKE ALARM

AS3660 - TERMITE PROTECTION

AS1926 - POOL FENCING

CONSULTANTS.

REFER STRUCTURAL ENGINEERS SPECIFICATION FOR
© SOIL TEST / SITE CLASSIFICATION

@ SLAB AND FOOTING DESIGN

¢ TIMBER FRAMING + LINTELS

@ POOL DESIGN

REFER TRUSS MANUFACTURERS SPECIFICATION FOR
@ TIMBER TRUSSES AND ROOF FRAMING.

REFER ROOF CONTRACTORS SPECIFICATION FOR

¢ SHEET ROOF FIXING AND ACCESSORIES.

ae | acter

AN
WY

SITE PLAN
Lot: §2

eat

SP : 163309
Parish: Tewantin
County: March
Area: 1324m?
Building

FootPrint 317 m?

Site Coverage 23.94%

+

AREA SCHEDULE

Internal Floor Area - 277.5 ma

South Deck - 9.0 me

North Deck - 11.0 mz

Outdoor Pavillion 19.5 mz

Access decking 6.5 m2

Entry - 6.0 ma

Total Floor Area - 329.50 mz
y :

w oR A Dp
GQBBA Lic. No. 07044

Kawana Junct

1/33 Premior Circuit.

Queanstand 457

7
lon

3.
8
1

adesign.com.au

 

 
    

Gorn

RTC si]s)

Rate

Project Description

  

Bulking 8 Real Estate levesiment
Leach Development Group

Ce ee

Proposed Residence

    

alec

eee

   

CURA cuk Led

 

Site Address.

Aspera

Lot 52

~Noosa Retreat~

Place

 

ertton consent by the author.

hese drawings remain copyright of MRA Design
land may not be used in pest orn whole without

 

Scale; 1:200

 

States:
Drawn: RDG

Date: 6/07/2007
[Checked By:

 

Project No:
2007 - 063

[Shoet No.

01 of 8

 

 

pot Dats:

 

 

 

Used in these records

About this file

File size
3.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2382 - MCU - Detached House [As Published].pdf · 3.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.