Council archive · source document
07/2382 - MCU - Detached House [As Published] · 132007.2382
ColorBond GustomOrb. Roof sheet Fixed to trusses via Steel Roof battens in accordance with Truss Manufacturers and Reof contractors Specification trusses connected to Top plate via G.1. looped strap. 4 2.8 Dia Nails each Leg. cee tinae, | an trusses connected to Beam via G.I. looped strap. 4 2.8 Dia Nails each Leg. Beam fixed to each Post Via 2 (M12 Bolts. ColorBond Fascia and gutter System S > 5 T— awa 6 et Src a . A” | maqf|......--.--------- we ences tE = WU) fe dee. F.C Soffit T | Fesom — ; : 4 Plasterboard | FC ceiling . ceiling lining | lining . | : | 1 240mm Brick Veneer. Beam / Truss Detail 1:10 Top plate / truss Detail 1:10 450mm Hardwood Post supporting Roof Beams QBBA Lie. No, O7D4IT 4/33 Premier Circuit. Kawane Junction Queensiand 4575. 908 971 49 49 in fradesign.com.au poo ann Baw e 5 F 6 3 m 3 3 @ CORROSION PROTECTION ALL METAL USED IN STRUCTURAL TIMBER, CONNECTIONS, SHALL BE PROVIDED WITH CORROSION PROTECTION APPROPRIATE FOR THE PARTICULAR CONDITIONS OF USE, WHERE CORROSION PROTECTION OF STEEL IS REQUIRED IT SHALL BE IN ACCORDANCE WITH ASINZS 4791, 4.5. 4397 and A.S.1214, THE LEVEL OF CORROSION PROTECTION PROVIDED SHALL TAKE INTO CONSIDERATION WEATHER EXPOSURE, TIMBER TREATMENT, MOISTURE AND PRESENCE OF SALT.THESE SHALL SATISFY THE REQUIREMENTS OF THE RELEVANT AUTHORITY.WHERE OTHER TYPES OF CORROSION PROTECTION ARE PROVIDED, STANDARDS REFERENCE DESIGN SHALL COMPLY TO ALL RELEVANT AUSTRALIAN STANDARDS & GENERAL BUILDING PRACTICE REFRENCES SOME LISTED BELOW BUILDING CODE OF AUSTRALIA 2006 “AS 1684.2 - 1999 - RESIDENTIAL TIMBER-FRAMED CONSTRUCTION AS32600 - CONCRETE STRUCTURES. -ASA100 - STEEL STRUCTURES -AS3700 - MASONRY STRUCTURES: +AS3500 - WATER SUPPLY -AS3786 - SMOKE ALARM. ~AS3660 - TERMITE PROTECTION -AS1926 - POOL FENCING CONSULTANTS. REFER STRUCTURAL ENGINEERS SPECIFICATION FOR © SOIL TEST / SITE CLASSIFICATION @ SLAB AND FOOTING DESIGN ¢ TIMBER FRAMING + LINTELS @ RAFTERS # POOL DESIGN REFER TRUSS MANUFACTURERS SPEC. ¢ TIMBER TRUSSES AND ROOF FRAMING, REFER ROOF CONTRACTORS SPEC. FOR @ SHEET ROOF FIXING AND ACCESSORIES, 90mm Frame / 40mm Cavity / 110 Brickwork. ———— Render and Paint Finish v i 5 M12 Bolt Counter bore Slab and footing in accordance with Engineers Specification Prefab GI Flat Stirrup Conceated in Post t Client masts ere eee ee ee ex oO oy Tee Brick / Block Column Y o °° as noted. jo (2 ° Ke Concrete Core fill Dy ° Oe vi omar! , = = Leach Development Group Prefab GI Flat Stirrup jo o jo °g ” Set in Core Fill y) bE 4 Oe “4 Ie a LY - ° oO Dey . ID Poffo %o Ta A anrikearia re uae a be O° Proposed Residence o ° v Sa Pe 1B 9 Lot 52 ) ° Oe Aspera Place > = ~Noosa Retreat~ e wd a These drawings remain copright of MRA Design Do Oc and may not ba used in part or in whole without jeritien consent by the author. ° ° » ° Scale: 1:10 4 e °n © °Al Stats: Date: 8107/2007 i Drew: RDG [Checked By. . . : j Project No: Sheet No: Footing Detail - Column Detail , a 1:10 4:19 (2007-083 07 of 8 . ‘ . Dats TOT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2382 - MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.