Council archive · source document
07/0924 - Op Works - Transport Type 5 - Domestic Marine [As Published] · 142007.924
KICKER:
76 x 38 HWOD
1/75 x No14 TYPE 17
STAINLESS
SCREWS @ 450 CRS
150 x 75 HWD WITH AS 2158 - PILING CODE
WITH 2/418 S/S BOLT
r
2 ~
\
:
SECTION (A
JETTY USE:
SINGLE USER, PRIVATE
NO VEHICULAR ACCESS
WALKWAY DECK VERTICAL
DESIGN LIVE LOAD - 2.0 kPa
MAXIMUM MOORED VESSEL - 5m
BERTHING VELOCITY - 0.5 m/sec
2M16 §
VLA I
@ 200 H8 MARINE HWD POLES {|
NOTE THAT ALL POLES TO COMPLY
WITH AS 2159 - PILING CODE
200
DETAIL ( 3 :
NOTES:
1, UNLESS NOTED OTHERWISE ALL TIMBER SHALL BE
DURABILITY CLASS 1 OF APPROVED SPECIES AND HAVE
A STRESS GRADE OF F14 MIN.
2. UNLESS NOTED OTHERWISE ALL CONSTRUCTION SHALL
COMPLY WITH THE ENVIRONMENTAL PROTECTION AGENCYS’
OPERATIONAL POLICY - “BUILDING AND ENGINEERING
STANDARDS FOR TIDAL WORKS.”
3. ALL STAINLESS STEEL BOLTS, RODS, ETC., SHALL BE
APPROVED MARINE GRADE 316. ALL OTHER STEELWORK
INCLUDING NUTS, BOLTS, WASHERS, SCREWS, NAILS, ETC.,
SHALL BE HOT DIPPED GALVANISED OR STAINLESS STEEL.
4. TOP OF PILES SHALL BE SEALED AND FULLY CAP FLASHED
OR RINGED.
5. DIMENSIONS AND LEVELS SHALL NOT BE SCALED FROM
THE DRAWINGS.
THE PROMONTORY
NOOSA WATERS
PTY LTD T/A
John Norden
& Associates
ACN 010 263 877
Strvctural | Chvil Design Engineers
‘Suite 16 ‘Tewentn Plaze’
Poinciena Avenue / PO Box 208
Tawantin Q 4565
Ph: O7 54467137 Fac OF 84497172
Emek:
Johnnorden_eescogpintemode.on.net
= Poe
ee
worknsyone
or64.2 [oo
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0924 - Op Works - Transport Type 5 - Domestic Marine [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.5 MB (small file)
- File type
No other editions are linked here.