Bushfire Risk Assessment v3 NCES REF: J001433
Select Areas of Noosa Springs Residential Estate, Noosa Heads
Calculated December 23, 2025, 5:23 pm (MDc v.4.9)
Area Area
2 SU6 VHC8.1
2 VHC 8.1
Minimum Distance Calculator - AS3959-2018 (Method 2)
Inputs Outputs
Fire Danger Index 48 Rate of spread 1.91 km/h
Vegetation
Forest Flame length 16.63 m
Classification
Understorey fuel load 31 t/ha Flame angle 41 °, 46 °, 52 °, 57 °, 59 ° & 73 °
5.23 m, 5.71 m, 6.22 m, 6.56 m, 6.67 m
Total fuel load 35 t/ha Elevation of receiver
& 7.08 m
Vegetation height n/a Fire intensity 34,596 kW/m
Effective slope 1° Transmissivity 0.878, 0.866, 0.85, 0.834, 0.826 & 0.771
0.597, 0.4395, 0.2928, 0.1956, 0.1588 &
Site slope 1° Viewfactor
0.0424
Minimum distance to < 40
Flame width 20 m 12.4 m
kW/m²
Minimum distance to < 29
Windspeed n/a 15 m
kW/m²
Minimum distance to < 19
Heat of combustion 18,600 kJ/kg 18.9 m
kW/m²
Minimum distance to < 12.5
Flame temperature 1,090 K 23.3 m
kW/m²
Minimum distance to < 10
25.9 m
kW/m²
Plate 19 – Area 2 VHC 8.1 – Wet eucalypt tall open forest - 1º
© 2026 29
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Reference Document - 152000.200053.3 - Bushfire Fire Risk Assessment (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.